ERDDAP
Easier access to scientific data |
|
Brought to you by NOAA NMFS SWFSC ERD |
| Grid DAP Data | Sub- set | Table DAP Data | Make A Graph | W M S | Source Data Files | Title | Sum- mary | FGDC, ISO, Metadata | Back- ground Info | RSS | E | Institution | Dataset ID | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| data | graph | RV Sikuliaq : SENSOR_MIXLG_11_ARCHIVE |
| M | background
|
|
|
| sensor_mixlg_11_archive |
| Row Type | Variable Name | Attribute Name | Data Type | Value |
|---|---|---|---|---|
| attribute | NC_GLOBAL | cdm_data_type | String | Other |
| attribute | NC_GLOBAL | creator_name | String | Oregon State University |
| attribute | NC_GLOBAL | creator_url | String | http://ceoas.oregonstate.edu![]() |
| attribute | NC_GLOBAL | infoUrl | String | http://ceoas.oregonstate.edu![]() |
| attribute | NC_GLOBAL | institution | String | Oregon State University |
| attribute | NC_GLOBAL | keywords | String | atmosphere, data, observations, ocean, vessel |
| attribute | NC_GLOBAL | license | String | The data may be used and redistributed for free but is not intended for legal use, since it may contain inaccuracies. Neither the data Contributor, ERD, NOAA, nor the United States Government, nor any of their employees or contractors, makes any warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, or assumes any legal liability for the accuracy, completeness, or usefulness, of this information. |
| attribute | NC_GLOBAL | sourceUrl | String | (source database) |
| attribute | NC_GLOBAL | summary | String | RCRV CORIOLIX |
| attribute | NC_GLOBAL | title | String | RV Sikuliaq : SENSOR_MIXLG_11_ARCHIVE |
| variable | time_raw | double | ||
| attribute | time_raw | ioos_category | String | Time |
| attribute | time_raw | long_name | String | Time Raw |
| attribute | time_raw | time_origin | String | 01-JAN-1970 00:00:00 |
| attribute | time_raw | units | String | seconds since 1970-01-01T00:00:00Z |
| variable | time | double | ||
| attribute | time | _CoordinateAxisType | String | Time |
| attribute | time | axis | String | T |
| attribute | time | ioos_category | String | Time |
| attribute | time | long_name | String | Time |
| attribute | time | standard_name | String | time |
| attribute | time | time_origin | String | 01-JAN-1970 00:00:00 |
| attribute | time | units | String | seconds since 1970-01-01T00:00:00Z |
| variable | sensor_id | String | ||
| attribute | sensor_id | ioos_category | String | Identifier |
| attribute | sensor_id | standard_name | String | xxxxxx |
| attribute | sensor_id | units | String | none |
| variable | pc01 | String | ||
| attribute | pc01 | ioos_category | String | Location |
| attribute | pc01 | long_name | String | GPS Latitude From An Attached GPS Unit |
| attribute | pc01 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pc01 | short_name | String | gps_latitude |
| attribute | pc01 | standard_name | String | xxxxxx |
| attribute | pc01 | units | String | degrees |
| variable | fc01 | String | ||
| attribute | fc01 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | fc01 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | fc01 | ioos_category | String | Location |
| attribute | fc01 | long_name | String | GPS Latitude From An Attached GPS Unit Status Flag |
| attribute | fc01 | short_name | String | gps_latitude Status Flag |
| attribute | fc01 | standard_name | String | xxxxxx_status_flag |
| attribute | fc01 | units | String | none |
| variable | pc02 | String | ||
| attribute | pc02 | ioos_category | String | Location |
| attribute | pc02 | long_name | String | GPS Longitude From An Attached GPS Unit |
| attribute | pc02 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pc02 | short_name | String | gps_longitude |
| attribute | pc02 | standard_name | String | xxxxxx |
| attribute | pc02 | units | String | degrees |
| variable | fc02 | String | ||
| attribute | fc02 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | fc02 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | fc02 | ioos_category | String | Location |
| attribute | fc02 | long_name | String | GPS Longitude From An Attached GPS Unit Status Flag |
| attribute | fc02 | short_name | String | gps_longitude Status Flag |
| attribute | fc02 | standard_name | String | xxxxxx_status_flag |
| attribute | fc02 | units | String | none |
| variable | pc03 | String | ||
| attribute | pc03 | ioos_category | String | Other |
| attribute | pc03 | long_name | String | Instrument Mode |
| attribute | pc03 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pc03 | short_name | String | instrument_mode |
| attribute | pc03 | standard_name | String | xxxxxx |
| variable | fc03 | String | ||
| attribute | fc03 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | fc03 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | fc03 | ioos_category | String | Other |
| attribute | fc03 | long_name | String | Instrument Mode Status Flag |
| attribute | fc03 | short_name | String | instrument_mode Status Flag |
| attribute | fc03 | standard_name | String | xxxxxx_status_flag |
| attribute | fc03 | units | String | none |
| variable | pc04 | String | ||
| attribute | pc04 | ioos_category | String | Other |
| attribute | pc04 | long_name | String | Sample Source |
| attribute | pc04 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pc04 | short_name | String | sample_source |
| attribute | pc04 | standard_name | String | xxxxxx |
| variable | fc04 | String | ||
| attribute | fc04 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | fc04 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | fc04 | ioos_category | String | Other |
| attribute | fc04 | long_name | String | Sample Source Status Flag |
| attribute | fc04 | short_name | String | sample_source Status Flag |
| attribute | fc04 | standard_name | String | xxxxxx_status_flag |
| attribute | fc04 | units | String | none |
| variable | pc05 | String | ||
| attribute | pc05 | ioos_category | String | Other |
| attribute | pc05 | long_name | String | Operator Identifier |
| attribute | pc05 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pc05 | short_name | String | operator |
| attribute | pc05 | standard_name | String | xxxxxxxx |
| variable | fc05 | String | ||
| attribute | fc05 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | fc05 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | fc05 | ioos_category | String | Other |
| attribute | fc05 | long_name | String | Operator Identifier Status Flag |
| attribute | fc05 | short_name | String | operator Status Flag |
| attribute | fc05 | standard_name | String | xxxxxxxx_status_flag |
| attribute | fc05 | units | String | none |
| variable | pc06 | String | ||
| attribute | pc06 | ioos_category | String | Other |
| attribute | pc06 | long_name | String | Overflow Alarm |
| attribute | pc06 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pc06 | short_name | String | overflow_alarm |
| attribute | pc06 | standard_name | String | xxxxxx |
| variable | fc06 | String | ||
| attribute | fc06 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | fc06 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | fc06 | ioos_category | String | Other |
| attribute | fc06 | long_name | String | Overflow Alarm Status Flag |
| attribute | fc06 | short_name | String | overflow_alarm Status Flag |
| attribute | fc06 | standard_name | String | xxxxxx_status_flag |
| attribute | fc06 | units | String | none |
| variable | pc07 | String | ||
| attribute | pc07 | ioos_category | String | Other |
| attribute | pc07 | long_name | String | Shutoff Valve Alarm |
| attribute | pc07 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pc07 | short_name | String | shutoff_valve_alarm |
| attribute | pc07 | standard_name | String | xxxxxx |
| variable | fc07 | String | ||
| attribute | fc07 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | fc07 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | fc07 | ioos_category | String | Other |
| attribute | fc07 | long_name | String | Shutoff Valve Alarm Status Flag |
| attribute | fc07 | short_name | String | shutoff_valve_alarm Status Flag |
| attribute | fc07 | standard_name | String | xxxxxx_status_flag |
| attribute | fc07 | units | String | none |
| variable | pc08 | String | ||
| attribute | pc08 | ioos_category | String | Unknown |
| attribute | pc08 | long_name | String | Test Type |
| attribute | pc08 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pc08 | short_name | String | test_type |
| attribute | pc08 | standard_name | String | xxxxxxxx |
| variable | fc08 | String | ||
| attribute | fc08 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | fc08 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | fc08 | ioos_category | String | Unknown |
| attribute | fc08 | long_name | String | Test Type Status Flag |
| attribute | fc08 | short_name | String | test_type Status Flag |
| attribute | fc08 | standard_name | String | xxxxxxxx_status_flag |
| attribute | fc08 | units | String | none |
| variable | pc09 | double | ||
| attribute | pc09 | ioos_category | String | Other |
| attribute | pc09 | long_name | String | Instrument Timestamp |
| attribute | pc09 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pc09 | short_name | String | instrument_timestamp |
| attribute | pc09 | standard_name | String | xxxxxx |
| variable | fc09 | String | ||
| attribute | fc09 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | fc09 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | fc09 | ioos_category | String | Other |
| attribute | fc09 | long_name | String | Instrument Timestamp Status Flag |
| attribute | fc09 | short_name | String | instrument_timestamp Status Flag |
| attribute | fc09 | standard_name | String | xxxxxx_status_flag |
| attribute | fc09 | units | String | none |
| variable | pc10 | double | ||
| attribute | pc10 | ioos_category | String | Other |
| attribute | pc10 | long_name | String | GPS Datetime From An Attached GPS Unit |
| attribute | pc10 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pc10 | short_name | String | gps_datetime |
| attribute | pc10 | standard_name | String | xxxxxx |
| variable | fc10 | String | ||
| attribute | fc10 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | fc10 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | fc10 | ioos_category | String | Other |
| attribute | fc10 | long_name | String | GPS Datetime From An Attached GPS Unit Status Flag |
| attribute | fc10 | short_name | String | gps_datetime Status Flag |
| attribute | fc10 | standard_name | String | xxxxxx_status_flag |
| attribute | fc10 | units | String | none |
| variable | pf01 | float | ||
| attribute | pf01 | ioos_category | String | CO2 |
| attribute | pf01 | long_name | String | LI-7815 xCO2 |
| attribute | pf01 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pf01 | short_name | String | li7815_xco2 |
| attribute | pf01 | standard_name | String | xxxxxx |
| attribute | pf01 | units | String | ppm |
| variable | ff01 | String | ||
| attribute | ff01 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | ff01 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | ff01 | ioos_category | String | CO2 |
| attribute | ff01 | long_name | String | LI-7815 xCO2 Status Flag |
| attribute | ff01 | short_name | String | li7815_xco2 Status Flag |
| attribute | ff01 | standard_name | String | xxxxxx_status_flag |
| attribute | ff01 | units | String | none |
| variable | pf02 | float | ||
| attribute | pf02 | ioos_category | String | Other |
| attribute | pf02 | long_name | String | LI-7815 xCO2 Standard Deviation |
| attribute | pf02 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pf02 | short_name | String | li7815_xco2_stdev |
| attribute | pf02 | standard_name | String | xxxxxx |
| attribute | pf02 | units | String | ppm |
| variable | ff02 | String | ||
| attribute | ff02 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | ff02 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | ff02 | ioos_category | String | Other |
| attribute | ff02 | long_name | String | LI-7815 xCO2 Standard Deviation Status Flag |
| attribute | ff02 | short_name | String | li7815_xco2_stdev Status Flag |
| attribute | ff02 | standard_name | String | xxxxxx_status_flag |
| attribute | ff02 | units | String | none |
| variable | pf03 | float | ||
| attribute | pf03 | ioos_category | String | Other |
| attribute | pf03 | long_name | String | xCO2 Corrected |
| attribute | pf03 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pf03 | short_name | String | xco2_corr |
| attribute | pf03 | standard_name | String | xxxxxx |
| attribute | pf03 | units | String | ppm |
| variable | ff03 | String | ||
| attribute | ff03 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | ff03 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | ff03 | ioos_category | String | Other |
| attribute | ff03 | long_name | String | xCO2 Corrected Status Flag |
| attribute | ff03 | short_name | String | xco2_corr Status Flag |
| attribute | ff03 | standard_name | String | xxxxxx_status_flag |
| attribute | ff03 | units | String | none |
| variable | pf04 | float | ||
| attribute | pf04 | ioos_category | String | Other |
| attribute | pf04 | long_name | String | LI-7815 H2O |
| attribute | pf04 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pf04 | short_name | String | li7815_h2o |
| attribute | pf04 | standard_name | String | xxxxxx |
| attribute | pf04 | units | String | 1/ml |
| variable | ff04 | String | ||
| attribute | ff04 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | ff04 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | ff04 | ioos_category | String | Other |
| attribute | ff04 | long_name | String | LI-7815 H2O Status Flag |
| attribute | ff04 | short_name | String | li7815_h2o Status Flag |
| attribute | ff04 | standard_name | String | xxxxxx_status_flag |
| attribute | ff04 | units | String | none |
| variable | pf05 | float | ||
| attribute | pf05 | ioos_category | String | Other |
| attribute | pf05 | long_name | String | LI-7815 Cavity Pressure |
| attribute | pf05 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pf05 | short_name | String | li7815_cavity_pressure |
| attribute | pf05 | standard_name | String | xxxxxx |
| attribute | pf05 | units | String | kPa |
| variable | ff05 | String | ||
| attribute | ff05 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | ff05 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | ff05 | ioos_category | String | Other |
| attribute | ff05 | long_name | String | LI-7815 Cavity Pressure Status Flag |
| attribute | ff05 | short_name | String | li7815_cavity_pressure Status Flag |
| attribute | ff05 | standard_name | String | xxxxxx_status_flag |
| attribute | ff05 | units | String | none |
| variable | pf06 | float | ||
| attribute | pf06 | ioos_category | String | Other |
| attribute | pf06 | long_name | String | LI-7815 Cavity Temperature |
| attribute | pf06 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pf06 | short_name | String | li7815_cavity_temperature |
| attribute | pf06 | standard_name | String | xxxxxxxx |
| attribute | pf06 | units | String | degrees_C |
| variable | ff06 | String | ||
| attribute | ff06 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | ff06 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | ff06 | ioos_category | String | Other |
| attribute | ff06 | long_name | String | LI-7815 Cavity Temperature Status Flag |
| attribute | ff06 | short_name | String | li7815_cavity_temperature Status Flag |
| attribute | ff06 | standard_name | String | xxxxxxxx_status_flag |
| attribute | ff06 | units | String | none |
| variable | pf07 | float | ||
| attribute | pf07 | ioos_category | String | Temperature |
| attribute | pf07 | long_name | String | Sea Water Temperature |
| attribute | pf07 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pf07 | short_name | String | sea_water_temperature |
| attribute | pf07 | standard_name | String | tempsu01 |
| attribute | pf07 | units | String | degrees_C |
| variable | ff07 | String | ||
| attribute | ff07 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | ff07 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | ff07 | ioos_category | String | Temperature |
| attribute | ff07 | long_name | String | Sea Water Temperature Status Flag |
| attribute | ff07 | short_name | String | sea_water_temperature Status Flag |
| attribute | ff07 | standard_name | String | tempsu01_status_flag |
| attribute | ff07 | units | String | none |
| variable | pf08 | float | ||
| attribute | pf08 | ioos_category | String | Other |
| attribute | pf08 | long_name | String | Sea Water Electrical Conductivity |
| attribute | pf08 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pf08 | short_name | String | sea_water_conductivity |
| attribute | pf08 | standard_name | String | cndcsg02 |
| attribute | pf08 | units | String | S/m |
| variable | ff08 | String | ||
| attribute | ff08 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | ff08 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | ff08 | ioos_category | String | Other |
| attribute | ff08 | long_name | String | Sea Water Electrical Conductivity Status Flag |
| attribute | ff08 | short_name | String | sea_water_conductivity Status Flag |
| attribute | ff08 | standard_name | String | cndcsg02_status_flag |
| attribute | ff08 | units | String | none |
| variable | pf09 | float | ||
| attribute | pf09 | ioos_category | String | Salinity |
| attribute | pf09 | long_name | String | Sea Water Practical Salinity |
| attribute | pf09 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pf09 | short_name | String | sea_water_practical_salinity |
| attribute | pf09 | standard_name | String | ssalsg01 |
| variable | ff09 | String | ||
| attribute | ff09 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | ff09 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | ff09 | ioos_category | String | Salinity |
| attribute | ff09 | long_name | String | Sea Water Practical Salinity Status Flag |
| attribute | ff09 | short_name | String | sea_water_practical_salinity Status Flag |
| attribute | ff09 | standard_name | String | ssalsg01_status_flag |
| attribute | ff09 | units | String | none |
| variable | pf10 | float | ||
| attribute | pf10 | ioos_category | String | Other |
| attribute | pf10 | long_name | String | Gas Flow Rate |
| attribute | pf10 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pf10 | short_name | String | gas_flow_rate |
| attribute | pf10 | standard_name | String | xxxxxx |
| attribute | pf10 | units | String | ml/minute |
| variable | ff10 | String | ||
| attribute | ff10 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | ff10 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | ff10 | ioos_category | String | Other |
| attribute | ff10 | long_name | String | Gas Flow Rate Status Flag |
| attribute | ff10 | short_name | String | gas_flow_rate Status Flag |
| attribute | ff10 | standard_name | String | xxxxxx_status_flag |
| attribute | ff10 | units | String | none |
| variable | pf11 | float | ||
| attribute | pf11 | ioos_category | String | Other |
| attribute | pf11 | long_name | String | Equilibrator Pressure |
| attribute | pf11 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pf11 | short_name | String | equilibrator_pressure |
| attribute | pf11 | standard_name | String | xxxxxx |
| attribute | pf11 | units | String | mbar |
| variable | ff11 | String | ||
| attribute | ff11 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | ff11 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | ff11 | ioos_category | String | Other |
| attribute | ff11 | long_name | String | Equilibrator Pressure Status Flag |
| attribute | ff11 | short_name | String | equilibrator_pressure Status Flag |
| attribute | ff11 | standard_name | String | xxxxxx_status_flag |
| attribute | ff11 | units | String | none |
| variable | pf12 | float | ||
| attribute | pf12 | ioos_category | String | Temperature |
| attribute | pf12 | long_name | String | Equilibrator Temperature |
| attribute | pf12 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pf12 | short_name | String | equilibrator_temperature |
| attribute | pf12 | standard_name | String | xxxxxx |
| attribute | pf12 | units | String | degrees_C |
| variable | ff12 | String | ||
| attribute | ff12 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | ff12 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | ff12 | ioos_category | String | Temperature |
| attribute | ff12 | long_name | String | Equilibrator Temperature Status Flag |
| attribute | ff12 | short_name | String | equilibrator_temperature Status Flag |
| attribute | ff12 | standard_name | String | xxxxxx_status_flag |
| attribute | ff12 | units | String | none |
| variable | pf13 | float | ||
| attribute | pf13 | ioos_category | String | Other |
| attribute | pf13 | long_name | String | Water Flow Rate |
| attribute | pf13 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pf13 | short_name | String | water_flow_rate |
| attribute | pf13 | standard_name | String | xxxxxx |
| attribute | pf13 | units | String | l/minute |
| variable | ff13 | String | ||
| attribute | ff13 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | ff13 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | ff13 | ioos_category | String | Other |
| attribute | ff13 | long_name | String | Water Flow Rate Status Flag |
| attribute | ff13 | short_name | String | water_flow_rate Status Flag |
| attribute | ff13 | standard_name | String | xxxxxx_status_flag |
| attribute | ff13 | units | String | none |
| variable | pf14 | float | ||
| attribute | pf14 | ioos_category | String | Other |
| attribute | pf14 | long_name | String | Cooling Pad Temperature |
| attribute | pf14 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pf14 | short_name | String | cooling_pad_temperature |
| attribute | pf14 | standard_name | String | xxxxxx |
| attribute | pf14 | units | String | degrees_C |
| variable | ff14 | String | ||
| attribute | ff14 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | ff14 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | ff14 | ioos_category | String | Other |
| attribute | ff14 | long_name | String | Cooling Pad Temperature Status Flag |
| attribute | ff14 | short_name | String | cooling_pad_temperature Status Flag |
| attribute | ff14 | standard_name | String | xxxxxx_status_flag |
| attribute | ff14 | units | String | none |
| variable | pf15 | float | ||
| attribute | pf15 | ioos_category | String | CO2 |
| attribute | pf15 | long_name | String | pCO2 Corrected |
| attribute | pf15 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pf15 | short_name | String | sea_water_pco2 |
| attribute | pf15 | standard_name | String | xxxxxx |
| attribute | pf15 | units | String | uatm |
| variable | ff15 | String | ||
| attribute | ff15 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | ff15 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | ff15 | ioos_category | String | CO2 |
| attribute | ff15 | long_name | String | pCO2 Corrected Status Flag |
| attribute | ff15 | short_name | String | sea_water_pco2 Status Flag |
| attribute | ff15 | standard_name | String | xxxxxx_status_flag |
| attribute | ff15 | units | String | none |
| variable | pf16 | float | ||
| attribute | pf16 | ioos_category | String | CO2 |
| attribute | pf16 | long_name | String | Partial Pressure of Carbon Dioxide in Air |
| attribute | pf16 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pf16 | short_name | String | air_pco2 |
| attribute | pf16 | standard_name | String | aco2ig01 |
| attribute | pf16 | units | String | uatm |
| variable | ff16 | String | ||
| attribute | ff16 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | ff16 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | ff16 | ioos_category | String | CO2 |
| attribute | ff16 | long_name | String | Partial Pressure of Carbon Dioxide in Air Status Flag |
| attribute | ff16 | short_name | String | air_pco2 Status Flag |
| attribute | ff16 | standard_name | String | aco2ig01_status_flag |
| attribute | ff16 | units | String | none |
| variable | pf17 | float | ||
| attribute | pf17 | ioos_category | String | CO2 |
| attribute | pf17 | long_name | String | Partial Pressure of CO2 in the equilibrator |
| attribute | pf17 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pf17 | short_name | String | equilibrator_pco2 |
| attribute | pf17 | standard_name | String | pco2eg01 |
| attribute | pf17 | units | String | utam |
| variable | ff17 | String | ||
| attribute | ff17 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | ff17 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | ff17 | ioos_category | String | CO2 |
| attribute | ff17 | long_name | String | Partial Pressure of CO2 in the equilibrator Status Flag |
| attribute | ff17 | short_name | String | equilibrator_pco2 Status Flag |
| attribute | ff17 | standard_name | String | pco2eg01_status_flag |
| attribute | ff17 | units | String | none |
| variable | pf18 | float | ||
| attribute | pf18 | ioos_category | String | Other |
| attribute | pf18 | long_name | String | Water Vapor Pressure |
| attribute | pf18 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pf18 | short_name | String | water_vapor_pressure |
| attribute | pf18 | standard_name | String | xxxxxx |
| attribute | pf18 | units | String | atm |
| variable | ff18 | String | ||
| attribute | ff18 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | ff18 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | ff18 | ioos_category | String | Other |
| attribute | ff18 | long_name | String | Water Vapor Pressure Status Flag |
| attribute | ff18 | short_name | String | water_vapor_pressure Status Flag |
| attribute | ff18 | standard_name | String | xxxxxx_status_flag |
| attribute | ff18 | units | String | none |
| variable | pf20 | float | ||
| attribute | pf20 | ioos_category | String | Other |
| attribute | pf20 | long_name | String | Measurement Standard Deviation |
| attribute | pf20 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pf20 | short_name | String | measurement_stdev |
| attribute | pf20 | standard_name | String | xxxxxxxx |
| attribute | pf20 | units | String | ppm |
| variable | ff20 | String | ||
| attribute | ff20 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | ff20 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | ff20 | ioos_category | String | Other |
| attribute | ff20 | long_name | String | Measurement Standard Deviation Status Flag |
| attribute | ff20 | short_name | String | measurement_stdev Status Flag |
| attribute | ff20 | standard_name | String | xxxxxxxx_status_flag |
| attribute | ff20 | units | String | none |
| variable | pi01 | byte | ||
| attribute | pi01 | ioos_category | String | Other |
| attribute | pi01 | long_name | String | LI-7815 Diagnostic |
| attribute | pi01 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pi01 | short_name | String | li7815_diagnostic |
| attribute | pi01 | standard_name | String | xxxxxx |
| variable | fi01 | String | ||
| attribute | fi01 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | fi01 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | fi01 | ioos_category | String | Other |
| attribute | fi01 | long_name | String | LI-7815 Diagnostic Status Flag |
| attribute | fi01 | short_name | String | li7815_diagnostic Status Flag |
| attribute | fi01 | standard_name | String | xxxxxx_status_flag |
| attribute | fi01 | units | String | none |
| variable | pi02 | byte | ||
| attribute | pi02 | ioos_category | String | Other |
| attribute | pi02 | long_name | String | Number of Measurements |
| attribute | pi02 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pi02 | short_name | String | number_of_measurements |
| attribute | pi02 | standard_name | String | xxxxxxxx |
| variable | fi02 | String | ||
| attribute | fi02 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | fi02 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | fi02 | ioos_category | String | Other |
| attribute | fi02 | long_name | String | Number of Measurements Status Flag |
| attribute | fi02 | short_name | String | number_of_measurements Status Flag |
| attribute | fi02 | standard_name | String | xxxxxxxx_status_flag |
| attribute | fi02 | units | String | none |
| variable | pi03 | short | ||
| attribute | pi03 | ioos_category | String | Other |
| attribute | pi03 | long_name | String | Measurement Interval |
| attribute | pi03 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pi03 | short_name | String | measurement_interval |
| attribute | pi03 | standard_name | String | xxxxxx |
| attribute | pi03 | units | String | s |
| variable | fi03 | String | ||
| attribute | fi03 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | fi03 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | fi03 | ioos_category | String | Other |
| attribute | fi03 | long_name | String | Measurement Interval Status Flag |
| attribute | fi03 | short_name | String | measurement_interval Status Flag |
| attribute | fi03 | standard_name | String | xxxxxx_status_flag |
| attribute | fi03 | units | String | none |
| variable | pi04 | short | ||
| attribute | pi04 | ioos_category | String | Other |
| attribute | pi04 | long_name | String | Purge Interval |
| attribute | pi04 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pi04 | short_name | String | purge_interval |
| attribute | pi04 | standard_name | String | xxxxxx |
| attribute | pi04 | units | String | s |
| variable | fi04 | String | ||
| attribute | fi04 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | fi04 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | fi04 | ioos_category | String | Other |
| attribute | fi04 | long_name | String | Purge Interval Status Flag |
| attribute | fi04 | short_name | String | purge_interval Status Flag |
| attribute | fi04 | standard_name | String | xxxxxx_status_flag |
| attribute | fi04 | units | String | none |
| variable | pi05 | short | ||
| attribute | pi05 | ioos_category | String | Other |
| attribute | pi05 | long_name | String | Measurement Flow Rate |
| attribute | pi05 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pi05 | short_name | String | measurement_flow_rate |
| attribute | pi05 | standard_name | String | xxxxxx |
| attribute | pi05 | units | String | ml/minute |
| variable | fi05 | String | ||
| attribute | fi05 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | fi05 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | fi05 | ioos_category | String | Other |
| attribute | fi05 | long_name | String | Measurement Flow Rate Status Flag |
| attribute | fi05 | short_name | String | measurement_flow_rate Status Flag |
| attribute | fi05 | standard_name | String | xxxxxx_status_flag |
| attribute | fi05 | units | String | none |
| variable | pi06 | short | ||
| attribute | pi06 | ioos_category | String | Other |
| attribute | pi06 | long_name | String | Purge Flow Rate |
| attribute | pi06 | sensor_description | String | pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable |
| attribute | pi06 | short_name | String | purge_flow_rate |
| attribute | pi06 | standard_name | String | xxxxxx |
| attribute | pi06 | units | String | ml/minute |
| variable | fi06 | String | ||
| attribute | fi06 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | fi06 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | fi06 | ioos_category | String | Other |
| attribute | fi06 | long_name | String | Purge Flow Rate Status Flag |
| attribute | fi06 | short_name | String | purge_flow_rate Status Flag |
| attribute | fi06 | standard_name | String | xxxxxx_status_flag |
| attribute | fi06 | units | String | none |
The information in the table above is also available in other file formats (.csv, .htmlTable, .itx, .json, .jsonlCSV1, .jsonlCSV, .jsonlKVP, .mat, .nc, .nccsv, .tsv, .xhtml) via a RESTful web service.