NOAA ERDDAP
Easier access to scientific data
| ?    
Brought to you by NOAA NMFS SWFSC ERD    

ERDDAP > tabledap > Data Access Form ?

Dataset Title:  RV Sikuliaq : SENSOR_MIXLG_11_ARCHIVE Subscribe RSS
Institution:  Oregon State University   (Dataset ID: sensor_mixlg_11_archive)
Information:  Summary ? | License ? | Metadata | Background (external link) | Make a graph
 
Variable ?   Optional
Constraint #1 ?
Optional
Constraint #2 ?
   Minimum ?
 
   Maximum ?
 
 time_raw (UTC) ?              
 time (UTC) ?              
 sensor_id (XXXXXX, none) ?              
 pc01 (degrees) ?              
 fc01 (none) ?              
 pc02 (degrees) ?              
 fc02 (none) ?              
 pc03 (Instrument Mode) ?              
 fc03 (none) ?              
 pc04 (Sample Source) ?              
 fc04 (Sample Source Status Flag, none) ?              
 pc05 (Operator Identifier) ?              
 fc05 (none) ?              
 pc06 (Overflow Alarm) ?              
 fc06 (none) ?              
 pc07 (Shutoff Valve Alarm) ?              
 fc07 (none) ?              
 pc08 (Test Type) ?              
 fc08 (Test Type Status Flag, none) ?              
 pc09 (Instrument Timestamp) ?              
 fc09 (none) ?              
 pc10 ?              
 fc10 (none) ?              
 pf01 (LI-7815 xCO2, ppm) ?              
 ff01 (LI-7815 xCO2 Status Flag, none) ?              
 pf02 (ppm) ?              
 ff02 (none) ?              
 pf03 (xCO2 Corrected, ppm) ?              
 ff03 (none) ?              
 pf04 (LI-7815 H2O, 1/ml) ?              
 ff04 (LI-7815 H2O Status Flag, none) ?              
 pf05 (LI-7815 Cavity Pressure, kPa) ?              
 ff05 (none) ?              
 pf06 (degrees_C) ?              
 ff06 (none) ?              
 pf07 (degrees_C) ?              
 ff07 (none) ?              
 pf08 (S/m) ?              
 ff08 (none) ?              
 pf09 (Sea Water Practical Salinity) ?              
 ff09 (none) ?              
 pf10 (Gas Flow Rate, ml/minute) ?              
 ff10 (Gas Flow Rate Status Flag, none) ?              
 pf11 (Equilibrator Pressure, mbar) ?              
 ff11 (none) ?              
 pf12 (degrees_C) ?              
 ff12 (none) ?              
 pf13 (Water Flow Rate, l/minute) ?              
 ff13 (none) ?              
 pf14 (degrees_C) ?              
 ff14 (none) ?              
 pf15 (pCO2 Corrected, uatm) ?              
 ff15 (none) ?              
 pf16 (uatm) ?              
 ff16 (none) ?              
 pf17 (utam) ?              
 ff17 (none) ?              
 pf18 (Water Vapor Pressure, atm) ?              
 ff18 (none) ?              
 pf20 (ppm) ?              
 ff20 (none) ?              
 pi01 (LI-7815 Diagnostic) ?              
 fi01 (none) ?              
 pi02 (Number of Measurements) ?              
 fi02 (none) ?              
 pi03 (Measurement Interval, s) ?              
 fi03 (none) ?              
 pi04 (Purge Interval, s) ?              
 fi04 (none) ?              
 pi05 (ml/minute) ?              
 fi05 (none) ?              
 pi06 (Purge Flow Rate, ml/minute) ?              
 fi06 (none) ?              
 
Server-side Functions ?
 distinct() ?
? ("Hover here to see a list of options. Click on an option to select it.Hover here to see a list of options. Click on an option to select it.Hover here to see a list of options. Click on an option to select it.Hover here to see a list of options. Click on an option to select it.Hover here to see a list of options. Click on an option to select it.")

File type: (more information)

(Documentation / Bypass this form ? )
 
(Please be patient. It may take a while to get the data.)


 

The Dataset Attribute Structure (.das) for this Dataset

Attributes {
 s {
  time_raw {
    String ioos_category "Time";
    String long_name "Time Raw";
    String time_origin "01-JAN-1970 00:00:00";
    String units "seconds since 1970-01-01T00:00:00Z";
  }
  time {
    String _CoordinateAxisType "Time";
    String axis "T";
    String ioos_category "Time";
    String long_name "Time";
    String standard_name "time";
    String time_origin "01-JAN-1970 00:00:00";
    String units "seconds since 1970-01-01T00:00:00Z";
  }
  sensor_id {
    String ioos_category "Identifier";
    String standard_name "xxxxxx";
    String units "none";
  }
  pc01 {
    String ioos_category "Location";
    String long_name "GPS Latitude From An Attached GPS Unit";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "gps_latitude";
    String standard_name "xxxxxx";
    String units "degrees";
  }
  fc01 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Location";
    String long_name "GPS Latitude From An Attached GPS Unit Status Flag";
    String short_name "gps_latitude Status Flag";
    String standard_name "xxxxxx_status_flag";
    String units "none";
  }
  pc02 {
    String ioos_category "Location";
    String long_name "GPS Longitude From An Attached GPS Unit";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "gps_longitude";
    String standard_name "xxxxxx";
    String units "degrees";
  }
  fc02 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Location";
    String long_name "GPS Longitude From An Attached GPS Unit Status Flag";
    String short_name "gps_longitude Status Flag";
    String standard_name "xxxxxx_status_flag";
    String units "none";
  }
  pc03 {
    String ioos_category "Other";
    String long_name "Instrument Mode";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "instrument_mode";
    String standard_name "xxxxxx";
  }
  fc03 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Other";
    String long_name "Instrument Mode Status Flag";
    String short_name "instrument_mode Status Flag";
    String standard_name "xxxxxx_status_flag";
    String units "none";
  }
  pc04 {
    String ioos_category "Other";
    String long_name "Sample Source";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "sample_source";
    String standard_name "xxxxxx";
  }
  fc04 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Other";
    String long_name "Sample Source Status Flag";
    String short_name "sample_source Status Flag";
    String standard_name "xxxxxx_status_flag";
    String units "none";
  }
  pc05 {
    String ioos_category "Other";
    String long_name "Operator Identifier";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "operator";
    String standard_name "xxxxxxxx";
  }
  fc05 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Other";
    String long_name "Operator Identifier Status Flag";
    String short_name "operator Status Flag";
    String standard_name "xxxxxxxx_status_flag";
    String units "none";
  }
  pc06 {
    String ioos_category "Other";
    String long_name "Overflow Alarm";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "overflow_alarm";
    String standard_name "xxxxxx";
  }
  fc06 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Other";
    String long_name "Overflow Alarm Status Flag";
    String short_name "overflow_alarm Status Flag";
    String standard_name "xxxxxx_status_flag";
    String units "none";
  }
  pc07 {
    String ioos_category "Other";
    String long_name "Shutoff Valve Alarm";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "shutoff_valve_alarm";
    String standard_name "xxxxxx";
  }
  fc07 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Other";
    String long_name "Shutoff Valve Alarm Status Flag";
    String short_name "shutoff_valve_alarm Status Flag";
    String standard_name "xxxxxx_status_flag";
    String units "none";
  }
  pc08 {
    String ioos_category "Unknown";
    String long_name "Test Type";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "test_type";
    String standard_name "xxxxxxxx";
  }
  fc08 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Unknown";
    String long_name "Test Type Status Flag";
    String short_name "test_type Status Flag";
    String standard_name "xxxxxxxx_status_flag";
    String units "none";
  }
  pc09 {
    String ioos_category "Other";
    String long_name "Instrument Timestamp";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "instrument_timestamp";
    String standard_name "xxxxxx";
  }
  fc09 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Other";
    String long_name "Instrument Timestamp Status Flag";
    String short_name "instrument_timestamp Status Flag";
    String standard_name "xxxxxx_status_flag";
    String units "none";
  }
  pc10 {
    String ioos_category "Other";
    String long_name "GPS Datetime From An Attached GPS Unit";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "gps_datetime";
    String standard_name "xxxxxx";
  }
  fc10 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Other";
    String long_name "GPS Datetime From An Attached GPS Unit Status Flag";
    String short_name "gps_datetime Status Flag";
    String standard_name "xxxxxx_status_flag";
    String units "none";
  }
  pf01 {
    String ioos_category "CO2";
    String long_name "LI-7815 xCO2";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "li7815_xco2";
    String standard_name "xxxxxx";
    String units "ppm";
  }
  ff01 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "CO2";
    String long_name "LI-7815 xCO2 Status Flag";
    String short_name "li7815_xco2 Status Flag";
    String standard_name "xxxxxx_status_flag";
    String units "none";
  }
  pf02 {
    String ioos_category "Other";
    String long_name "LI-7815 xCO2 Standard Deviation";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "li7815_xco2_stdev";
    String standard_name "xxxxxx";
    String units "ppm";
  }
  ff02 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Other";
    String long_name "LI-7815 xCO2 Standard Deviation Status Flag";
    String short_name "li7815_xco2_stdev Status Flag";
    String standard_name "xxxxxx_status_flag";
    String units "none";
  }
  pf03 {
    String ioos_category "Other";
    String long_name "xCO2 Corrected";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "xco2_corr";
    String standard_name "xxxxxx";
    String units "ppm";
  }
  ff03 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Other";
    String long_name "xCO2 Corrected Status Flag";
    String short_name "xco2_corr Status Flag";
    String standard_name "xxxxxx_status_flag";
    String units "none";
  }
  pf04 {
    String ioos_category "Other";
    String long_name "LI-7815 H2O";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "li7815_h2o";
    String standard_name "xxxxxx";
    String units "1/ml";
  }
  ff04 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Other";
    String long_name "LI-7815 H2O Status Flag";
    String short_name "li7815_h2o Status Flag";
    String standard_name "xxxxxx_status_flag";
    String units "none";
  }
  pf05 {
    String ioos_category "Other";
    String long_name "LI-7815 Cavity Pressure";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "li7815_cavity_pressure";
    String standard_name "xxxxxx";
    String units "kPa";
  }
  ff05 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Other";
    String long_name "LI-7815 Cavity Pressure Status Flag";
    String short_name "li7815_cavity_pressure Status Flag";
    String standard_name "xxxxxx_status_flag";
    String units "none";
  }
  pf06 {
    String ioos_category "Other";
    String long_name "LI-7815 Cavity Temperature";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "li7815_cavity_temperature";
    String standard_name "xxxxxxxx";
    String units "degrees_C";
  }
  ff06 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Other";
    String long_name "LI-7815 Cavity Temperature Status Flag";
    String short_name "li7815_cavity_temperature Status Flag";
    String standard_name "xxxxxxxx_status_flag";
    String units "none";
  }
  pf07 {
    String ioos_category "Temperature";
    String long_name "Sea Water Temperature";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "sea_water_temperature";
    String standard_name "tempsu01";
    String units "degrees_C";
  }
  ff07 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Temperature";
    String long_name "Sea Water Temperature Status Flag";
    String short_name "sea_water_temperature Status Flag";
    String standard_name "tempsu01_status_flag";
    String units "none";
  }
  pf08 {
    String ioos_category "Other";
    String long_name "Sea Water Electrical Conductivity";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "sea_water_conductivity";
    String standard_name "cndcsg02";
    String units "S/m";
  }
  ff08 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Other";
    String long_name "Sea Water Electrical Conductivity Status Flag";
    String short_name "sea_water_conductivity Status Flag";
    String standard_name "cndcsg02_status_flag";
    String units "none";
  }
  pf09 {
    String ioos_category "Salinity";
    String long_name "Sea Water Practical Salinity";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "sea_water_practical_salinity";
    String standard_name "ssalsg01";
  }
  ff09 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Salinity";
    String long_name "Sea Water Practical Salinity Status Flag";
    String short_name "sea_water_practical_salinity Status Flag";
    String standard_name "ssalsg01_status_flag";
    String units "none";
  }
  pf10 {
    String ioos_category "Other";
    String long_name "Gas Flow Rate";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "gas_flow_rate";
    String standard_name "xxxxxx";
    String units "ml/minute";
  }
  ff10 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Other";
    String long_name "Gas Flow Rate Status Flag";
    String short_name "gas_flow_rate Status Flag";
    String standard_name "xxxxxx_status_flag";
    String units "none";
  }
  pf11 {
    String ioos_category "Other";
    String long_name "Equilibrator Pressure";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "equilibrator_pressure";
    String standard_name "xxxxxx";
    String units "mbar";
  }
  ff11 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Other";
    String long_name "Equilibrator Pressure Status Flag";
    String short_name "equilibrator_pressure Status Flag";
    String standard_name "xxxxxx_status_flag";
    String units "none";
  }
  pf12 {
    String ioos_category "Temperature";
    String long_name "Equilibrator Temperature";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "equilibrator_temperature";
    String standard_name "xxxxxx";
    String units "degrees_C";
  }
  ff12 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Temperature";
    String long_name "Equilibrator Temperature Status Flag";
    String short_name "equilibrator_temperature Status Flag";
    String standard_name "xxxxxx_status_flag";
    String units "none";
  }
  pf13 {
    String ioos_category "Other";
    String long_name "Water Flow Rate";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "water_flow_rate";
    String standard_name "xxxxxx";
    String units "l/minute";
  }
  ff13 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Other";
    String long_name "Water Flow Rate Status Flag";
    String short_name "water_flow_rate Status Flag";
    String standard_name "xxxxxx_status_flag";
    String units "none";
  }
  pf14 {
    String ioos_category "Other";
    String long_name "Cooling Pad Temperature";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "cooling_pad_temperature";
    String standard_name "xxxxxx";
    String units "degrees_C";
  }
  ff14 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Other";
    String long_name "Cooling Pad Temperature Status Flag";
    String short_name "cooling_pad_temperature Status Flag";
    String standard_name "xxxxxx_status_flag";
    String units "none";
  }
  pf15 {
    String ioos_category "CO2";
    String long_name "pCO2 Corrected";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "sea_water_pco2";
    String standard_name "xxxxxx";
    String units "uatm";
  }
  ff15 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "CO2";
    String long_name "pCO2 Corrected Status Flag";
    String short_name "sea_water_pco2 Status Flag";
    String standard_name "xxxxxx_status_flag";
    String units "none";
  }
  pf16 {
    String ioos_category "CO2";
    String long_name "Partial Pressure of Carbon Dioxide in Air";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "air_pco2";
    String standard_name "aco2ig01";
    String units "uatm";
  }
  ff16 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "CO2";
    String long_name "Partial Pressure of Carbon Dioxide in Air Status Flag";
    String short_name "air_pco2 Status Flag";
    String standard_name "aco2ig01_status_flag";
    String units "none";
  }
  pf17 {
    String ioos_category "CO2";
    String long_name "Partial Pressure of CO2 in the equilibrator";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "equilibrator_pco2";
    String standard_name "pco2eg01";
    String units "utam";
  }
  ff17 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "CO2";
    String long_name "Partial Pressure of CO2 in the equilibrator Status Flag";
    String short_name "equilibrator_pco2 Status Flag";
    String standard_name "pco2eg01_status_flag";
    String units "none";
  }
  pf18 {
    String ioos_category "Other";
    String long_name "Water Vapor Pressure";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "water_vapor_pressure";
    String standard_name "xxxxxx";
    String units "atm";
  }
  ff18 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Other";
    String long_name "Water Vapor Pressure Status Flag";
    String short_name "water_vapor_pressure Status Flag";
    String standard_name "xxxxxx_status_flag";
    String units "none";
  }
  pf20 {
    String ioos_category "Other";
    String long_name "Measurement Standard Deviation";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "measurement_stdev";
    String standard_name "xxxxxxxx";
    String units "ppm";
  }
  ff20 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Other";
    String long_name "Measurement Standard Deviation Status Flag";
    String short_name "measurement_stdev Status Flag";
    String standard_name "xxxxxxxx_status_flag";
    String units "none";
  }
  pi01 {
    String _Unsigned "false";
    String ioos_category "Other";
    String long_name "LI-7815 Diagnostic";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "li7815_diagnostic";
    String standard_name "xxxxxx";
  }
  fi01 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Other";
    String long_name "LI-7815 Diagnostic Status Flag";
    String short_name "li7815_diagnostic Status Flag";
    String standard_name "xxxxxx_status_flag";
    String units "none";
  }
  pi02 {
    String _Unsigned "false";
    String ioos_category "Other";
    String long_name "Number of Measurements";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "number_of_measurements";
    String standard_name "xxxxxxxx";
  }
  fi02 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Other";
    String long_name "Number of Measurements Status Flag";
    String short_name "number_of_measurements Status Flag";
    String standard_name "xxxxxxxx_status_flag";
    String units "none";
  }
  pi03 {
    String ioos_category "Other";
    String long_name "Measurement Interval";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "measurement_interval";
    String standard_name "xxxxxx";
    String units "s";
  }
  fi03 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Other";
    String long_name "Measurement Interval Status Flag";
    String short_name "measurement_interval Status Flag";
    String standard_name "xxxxxx_status_flag";
    String units "none";
  }
  pi04 {
    String ioos_category "Other";
    String long_name "Purge Interval";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "purge_interval";
    String standard_name "xxxxxx";
    String units "s";
  }
  fi04 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Other";
    String long_name "Purge Interval Status Flag";
    String short_name "purge_interval Status Flag";
    String standard_name "xxxxxx_status_flag";
    String units "none";
  }
  pi05 {
    String ioos_category "Other";
    String long_name "Measurement Flow Rate";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "measurement_flow_rate";
    String standard_name "xxxxxx";
    String units "ml/minute";
  }
  fi05 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Other";
    String long_name "Measurement Flow Rate Status Flag";
    String short_name "measurement_flow_rate Status Flag";
    String standard_name "xxxxxx_status_flag";
    String units "none";
  }
  pi06 {
    String ioos_category "Other";
    String long_name "Purge Flow Rate";
    String sensor_description "pCO2_Apollo : Apollo Scitech Apollo SciTech AS-P3 combined pCO2 analyser and underway system 2101-OSU : Not Applicable";
    String short_name "purge_flow_rate";
    String standard_name "xxxxxx";
    String units "ml/minute";
  }
  fi06 {
    String flag_notes "Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.";
    String flag_order "0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,";
    String ioos_category "Other";
    String long_name "Purge Flow Rate Status Flag";
    String short_name "purge_flow_rate Status Flag";
    String standard_name "xxxxxx_status_flag";
    String units "none";
  }
 }
  NC_GLOBAL {
    String cdm_data_type "Other";
    String creator_name "Oregon State University";
    String creator_url "http://ceoas.oregonstate.edu";
    String history 
"2025-10-30T03:59:58Z (source database)
2025-10-30T03:59:58Z https://coriolix.sikuliaq.alaska.edu/erddap/tabledap/sensor_mixlg_11_archive.html";
    String infoUrl "http://ceoas.oregonstate.edu";
    String institution "Oregon State University";
    String keywords "atmosphere, data, observations, ocean, vessel";
    String license 
"The data may be used and redistributed for free but is not intended
for legal use, since it may contain inaccuracies. Neither the data
Contributor, ERD, NOAA, nor the United States Government, nor any
of their employees or contractors, makes any warranty, express or
implied, including warranties of merchantability and fitness for a
particular purpose, or assumes any legal liability for the accuracy,
completeness, or usefulness, of this information.";
    String sourceUrl "(source database)";
    String summary "RCRV CORIOLIX";
    String title "RV Sikuliaq : SENSOR_MIXLG_11_ARCHIVE";
  }
}

 

Using tabledap to Request Data and Graphs from Tabular Datasets

tabledap lets you request a data subset, a graph, or a map from a tabular dataset (for example, buoy data), via a specially formed URL. tabledap uses the OPeNDAP (external link) Data Access Protocol (DAP) (external link) and its selection constraints (external link).

The URL specifies what you want: the dataset, a description of the graph or the subset of the data, and the file type for the response.

Tabledap request URLs must be in the form
https://coastwatch.pfeg.noaa.gov/erddap/tabledap/datasetID.fileType{?query}
For example,
https://coastwatch.pfeg.noaa.gov/erddap/tabledap/pmelTaoDySst.htmlTable?longitude,latitude,time,station,wmo_platform_code,T_25&time>=2015-05-23T12:00:00Z&time<=2015-05-31T12:00:00Z
Thus, the query is often a comma-separated list of desired variable names, followed by a collection of constraints (e.g., variable<value), each preceded by '&' (which is interpreted as "AND").

For details, see the tabledap Documentation.


 
ERDDAP, Version 2.23
Disclaimers | Privacy Policy | Contact