NOAA ERDDAP
Easier access to scientific data
| ?    
Brought to you by NOAA NMFS SWFSC ERD    

ERDDAP > info > supplyvoltage_v_oxygen083431_fullres

Grid
DAP
Data
Sub-
set
Table
DAP
Data
Make
A
Graph
W
M
S
Source
Data
Files
Title Sum-
mary
FGDC,
ISO,
Metadata
Back-
ground
Info
RSS E
mail
Institution Dataset ID
     data   graph     RV Sikuliaq : TDGP Pro-Oceanus_83431 : Supply Voltage    ?            M   background (external link) RSS Subscribe UAF supplyvoltage_v_oxygen083431_fullres

The Dataset's Variables and Attributes

Row Type Variable Name Attribute Name Data Type Value
attribute NC_GLOBAL cdm_data_type String Other
attribute NC_GLOBAL contributor_name String RV Sikuliaq
attribute NC_GLOBAL contributor_role String Data collector
attribute NC_GLOBAL creator_name String CORIOLIX, RDESC, RCRV Project, Oregon State University
attribute NC_GLOBAL creator_url String http://ceoas.oregonstate.edu (external link)
attribute NC_GLOBAL infoUrl String https://www.uaf.edu/cfos/sikuliaq/ (external link)
attribute NC_GLOBAL institution String UAF
attribute NC_GLOBAL keywords String atmosphere, data, observations, ocean
attribute NC_GLOBAL license String The data may be used and redistributed for free but is not intended
for legal use, since it may contain inaccuracies. Neither the data
Contributor, ERD, NOAA, nor the United States Government, nor any
of their employees or contractors, makes any warranty, express or
implied, including warranties of merchantability and fitness for a
particular purpose, or assumes any legal liability for the accuracy,
completeness, or usefulness, of this information.
attribute NC_GLOBAL sourceUrl String (source database)
attribute NC_GLOBAL standard_name_vocabulary String CF standard name
attribute NC_GLOBAL summary String Supply Voltage time series data.
Platform: RV Sikuliaq
Sensor Model: Pro-Oceanus Mini TDGP submersible dissolved gas sensor
Sensor S/N: 41-834-31
Sensor Location Onboard: Main Lab / Wet Wall
Sensor Description: The Mini TDGP measures the total dissolved gas pressure in liquids via a semi-permeable membrane.
Parameter Description: The supply voltage reflects the current voltage applied to the sensor. The output is utilized for diagnostic purposes to monitor the stability of the sensors power supply.
attribute NC_GLOBAL title String RV Sikuliaq : TDGP Pro-Oceanus_83431 : Supply Voltage
variable time_raw   double  
attribute time_raw ioos_category String Time
attribute time_raw long_name String Time Raw
attribute time_raw time_origin String 01-JAN-1970 00:00:00
attribute time_raw units String seconds since 1970-01-01T00:00:00Z
variable time   double  
attribute time _CoordinateAxisType String Time
attribute time axis String T
attribute time ioos_category String Time
attribute time long_name String Time
attribute time standard_name String time
attribute time time_origin String 01-JAN-1970 00:00:00
attribute time units String seconds since 1970-01-01T00:00:00Z
variable value   double  
attribute value ioos_category String Other
attribute value long_name String Supply Voltage
attribute value parameter_description String The supply voltage reflects the current voltage applied to the sensor. The output is utilized for diagnostic purposes to monitor the stability of the sensors power supply.
attribute value short_name String supply_voltage
attribute value standard_name String x
attribute value units String V
variable flag_summary   int  
attribute flag_summary colorBarMaximum String 9
attribute flag_summary colorBarMinimum String 0
attribute flag_summary flag_meanings String QC test not applicable, passed the QC test, quality was not evaluated or is unknown, quality is questionable/suspect, failed the QC test, data are missing
attribute flag_summary flag_values String 0, 1, 2, 3, 4, 9
attribute flag_summary ioos_category String Quality
attribute flag_summary long_name String Supply Voltage QC Summary Flag
attribute flag_summary short_name String supply_voltage_qc_flag
attribute flag_summary standard_name String x_qc_flag
attribute flag_summary units String unitless
variable flag_string   String  
attribute flag_string flag_meanings String QC test not applicable, passed the QC test, quality was not evaluated or is unknown, quality is questionable/suspect, failed the QC test, data are missing
attribute flag_string flag_values String 0, 1, 2, 3, 4, 9
attribute flag_string ioos_category String Quality
attribute flag_string long_name String Supply Voltage QC Flags
attribute flag_string qc_test_indices String 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29
attribute flag_string qc_test_names String Gap Test, Syntax Test, Gross Range Test, Global Range Test, Recommended Range Test, Sensor Status Test, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused
attribute flag_string short_name String supply_voltage_qc_flag_string
attribute flag_string standard_name String x_qc_flag_string
attribute flag_string units String unitless

The information in the table above is also available in other file formats (.csv, .htmlTable, .itx, .json, .jsonlCSV1, .jsonlCSV, .jsonlKVP, .mat, .nc, .nccsv, .tsv, .xhtml) via a RESTful web service.


 
ERDDAP, Version 2.23
Disclaimers | Privacy Policy | Contact