ERDDAP
Easier access to scientific data |
|
Brought to you by NOAA NMFS SWFSC ERD |
| Grid DAP Data | Sub- set | Table DAP Data | Make A Graph | W M S | Source Data Files | Title | Sum- mary | FGDC, ISO, Metadata | Back- ground Info | RSS | E | Institution | Dataset ID | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| data | graph | RV Sikuliaq : SENSOR_MIXED_17_ARCHIVE |
| M | background
|
|
|
| sensor_mixed_17_archive |
| Row Type | Variable Name | Attribute Name | Data Type | Value |
|---|---|---|---|---|
| attribute | NC_GLOBAL | cdm_data_type | String | Other |
| attribute | NC_GLOBAL | creator_name | String | Oregon State University |
| attribute | NC_GLOBAL | creator_url | String | http://ceoas.oregonstate.edu![]() |
| attribute | NC_GLOBAL | infoUrl | String | http://ceoas.oregonstate.edu![]() |
| attribute | NC_GLOBAL | institution | String | Oregon State University |
| attribute | NC_GLOBAL | keywords | String | atmosphere, data, observations, ocean, vessel |
| attribute | NC_GLOBAL | license | String | The data may be used and redistributed for free but is not intended for legal use, since it may contain inaccuracies. Neither the data Contributor, ERD, NOAA, nor the United States Government, nor any of their employees or contractors, makes any warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, or assumes any legal liability for the accuracy, completeness, or usefulness, of this information. |
| attribute | NC_GLOBAL | sourceUrl | String | (source database) |
| attribute | NC_GLOBAL | summary | String | RCRV CORIOLIX |
| attribute | NC_GLOBAL | title | String | RV Sikuliaq : SENSOR_MIXED_17_ARCHIVE |
| variable | time_raw | double | ||
| attribute | time_raw | ioos_category | String | Time |
| attribute | time_raw | long_name | String | Time Raw |
| attribute | time_raw | time_origin | String | 01-JAN-1970 00:00:00 |
| attribute | time_raw | units | String | seconds since 1970-01-01T00:00:00Z |
| variable | time | double | ||
| attribute | time | _CoordinateAxisType | String | Time |
| attribute | time | axis | String | T |
| attribute | time | ioos_category | String | Time |
| attribute | time | long_name | String | Time |
| attribute | time | standard_name | String | time |
| attribute | time | time_origin | String | 01-JAN-1970 00:00:00 |
| attribute | time | units | String | seconds since 1970-01-01T00:00:00Z |
| variable | sensor_id | String | ||
| attribute | sensor_id | ioos_category | String | Identifier |
| attribute | sensor_id | standard_name | String | xxxxxx |
| attribute | sensor_id | units | String | none |
| variable | p11 | ushort | ||
| attribute | p11 | ioos_category | String | Wind |
| attribute | p11 | long_name | String | X Wind Component |
| attribute | p11 | sensor_description | String | Anemometer Metek_0194 : Metek Metek uSonic-3 Scientific {formerly: USA-1} ultrasonic anemometer 0118010194 : Tech Stores |
| attribute | p11 | short_name | String | x |
| attribute | p11 | standard_name | String | xxxxxx |
| attribute | p11 | units | String | cm/s |
| variable | f11 | String | ||
| attribute | f11 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | f11 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | f11 | ioos_category | String | Wind |
| attribute | f11 | long_name | String | X Wind Component Status Flag |
| attribute | f11 | short_name | String | x Status Flag |
| attribute | f11 | standard_name | String | xxxxxx_status_flag |
| attribute | f11 | units | String | none |
| variable | p12 | ushort | ||
| attribute | p12 | ioos_category | String | Wind |
| attribute | p12 | long_name | String | Y Wind Component |
| attribute | p12 | sensor_description | String | Anemometer Metek_0194 : Metek Metek uSonic-3 Scientific {formerly: USA-1} ultrasonic anemometer 0118010194 : Tech Stores |
| attribute | p12 | short_name | String | y |
| attribute | p12 | standard_name | String | xxxxxx |
| attribute | p12 | units | String | cm/s |
| variable | f12 | String | ||
| attribute | f12 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | f12 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | f12 | ioos_category | String | Wind |
| attribute | f12 | long_name | String | Y Wind Component Status Flag |
| attribute | f12 | short_name | String | y Status Flag |
| attribute | f12 | standard_name | String | xxxxxx_status_flag |
| attribute | f12 | units | String | none |
| variable | p13 | ushort | ||
| attribute | p13 | ioos_category | String | Wind |
| attribute | p13 | long_name | String | Z Wind Component |
| attribute | p13 | sensor_description | String | Anemometer Metek_0194 : Metek Metek uSonic-3 Scientific {formerly: USA-1} ultrasonic anemometer 0118010194 : Tech Stores |
| attribute | p13 | short_name | String | z |
| attribute | p13 | standard_name | String | xxxxxx |
| attribute | p13 | units | String | cm/s |
| variable | f13 | String | ||
| attribute | f13 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | f13 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | f13 | ioos_category | String | Wind |
| attribute | f13 | long_name | String | Z Wind Component Status Flag |
| attribute | f13 | short_name | String | z Status Flag |
| attribute | f13 | standard_name | String | xxxxxx_status_flag |
| attribute | f13 | units | String | none |
| variable | p14 | ubyte | ||
| attribute | p14 | ioos_category | String | Other |
| attribute | p14 | long_name | String | Data Quality |
| attribute | p14 | sensor_description | String | Anemometer Metek_8639 : Metek Metek uSonic-3 Scientific {formerly: USA-1} ultrasonic anemometer 0114098639 : Forward Mast |
| attribute | p14 | short_name | String | Quality |
| attribute | p14 | standard_name | String | xxxxxx |
| attribute | p14 | units | String | % |
| variable | f14 | String | ||
| attribute | f14 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | f14 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | f14 | ioos_category | String | Other |
| attribute | f14 | long_name | String | Data Quality Status Flag |
| attribute | f14 | short_name | String | Quality Status Flag |
| attribute | f14 | standard_name | String | xxxxxx_status_flag |
| attribute | f14 | units | String | none |
| variable | p21 | char | ||
| attribute | p21 | ioos_category | String | Other |
| attribute | p21 | long_name | String | Measurement Mode |
| attribute | p21 | sensor_description | String | Anemometer Metek_8639 : Metek Metek uSonic-3 Scientific {formerly: USA-1} ultrasonic anemometer 0114098639 : Forward Mast |
| attribute | p21 | short_name | String | Mode |
| attribute | p21 | standard_name | String | xxxxxx |
| variable | f21 | String | ||
| attribute | f21 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | f21 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | f21 | ioos_category | String | Other |
| attribute | f21 | long_name | String | Measurement Mode Status Flag |
| attribute | f21 | short_name | String | Mode Status Flag |
| attribute | f21 | standard_name | String | xxxxxx_status_flag |
| attribute | f21 | units | String | none |
| variable | p3 | float | ||
| attribute | p3 | ioos_category | String | Other |
| attribute | p3 | long_name | String | Acoustic Temperature |
| attribute | p3 | sensor_description | String | Anemometer Metek_8639 : Metek Metek uSonic-3 Scientific {formerly: USA-1} ultrasonic anemometer 0114098639 : Forward Mast |
| attribute | p3 | short_name | String | Acoustic Temp |
| attribute | p3 | standard_name | String | xxxxxx |
| attribute | p3 | units | String | degrees_C |
| variable | f3 | String | ||
| attribute | f3 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | f3 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | f3 | ioos_category | String | Other |
| attribute | f3 | long_name | String | Acoustic Temperature Status Flag |
| attribute | f3 | short_name | String | Acoustic Temp Status Flag |
| attribute | f3 | standard_name | String | xxxxxx_status_flag |
| attribute | f3 | units | String | none |
| variable | p4 | float | ||
| attribute | p4 | ioos_category | String | Wind |
| attribute | p4 | long_name | String | Relative Wind Direction |
| attribute | p4 | sensor_description | String | Anemometer Metek_8639 : Metek Metek uSonic-3 Scientific {formerly: USA-1} ultrasonic anemometer 0114098639 : Forward Mast |
| attribute | p4 | short_name | String | Rel Wind Dir |
| attribute | p4 | standard_name | String | xxxxxx |
| attribute | p4 | units | String | degrees |
| variable | f4 | String | ||
| attribute | f4 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | f4 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | f4 | ioos_category | String | Wind |
| attribute | f4 | long_name | String | Relative Wind Direction Status Flag |
| attribute | f4 | short_name | String | Rel Wind Dir Status Flag |
| attribute | f4 | standard_name | String | xxxxxx_status_flag |
| attribute | f4 | units | String | none |
| variable | p5 | float | ||
| attribute | p5 | ioos_category | String | Wind |
| attribute | p5 | long_name | String | Relative Wind Speed |
| attribute | p5 | sensor_description | String | Anemometer Metek_0194 : Metek Metek uSonic-3 Scientific {formerly: USA-1} ultrasonic anemometer 0118010194 : Tech Stores |
| attribute | p5 | short_name | String | Rel Wind Spd |
| attribute | p5 | standard_name | String | xxxxxx |
| attribute | p5 | units | String | cm/s |
| variable | f5 | String | ||
| attribute | f5 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | f5 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | f5 | ioos_category | String | Wind |
| attribute | f5 | long_name | String | Relative Wind Speed Status Flag |
| attribute | f5 | short_name | String | Rel Wind Spd Status Flag |
| attribute | f5 | standard_name | String | xxxxxx_status_flag |
| attribute | f5 | units | String | none |
| variable | p6 | float | ||
| attribute | p6 | ioos_category | String | Wind |
| attribute | p6 | long_name | String | True Wind Direction |
| attribute | p6 | sensor_description | String | Anemometer Metek_0194 : Metek Metek uSonic-3 Scientific {formerly: USA-1} ultrasonic anemometer 0118010194 : Tech Stores |
| attribute | p6 | short_name | String | True Wind Dir |
| attribute | p6 | standard_name | String | xxxxxx |
| attribute | p6 | units | String | degrees_true |
| variable | f6 | String | ||
| attribute | f6 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | f6 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | f6 | ioos_category | String | Wind |
| attribute | f6 | long_name | String | True Wind Direction Status Flag |
| attribute | f6 | short_name | String | True Wind Dir Status Flag |
| attribute | f6 | standard_name | String | xxxxxx_status_flag |
| attribute | f6 | units | String | none |
| variable | p7 | float | ||
| attribute | p7 | ioos_category | String | Wind |
| attribute | p7 | long_name | String | True Wind Speed |
| attribute | p7 | sensor_description | String | Anemometer Metek_0194 : Metek Metek uSonic-3 Scientific {formerly: USA-1} ultrasonic anemometer 0118010194 : Tech Stores |
| attribute | p7 | short_name | String | True Wind Spd |
| attribute | p7 | standard_name | String | xxxxxx |
| attribute | p7 | units | String | cm/s |
| variable | f7 | String | ||
| attribute | f7 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | f7 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | f7 | ioos_category | String | Wind |
| attribute | f7 | long_name | String | True Wind Speed Status Flag |
| attribute | f7 | short_name | String | True Wind Spd Status Flag |
| attribute | f7 | standard_name | String | xxxxxx_status_flag |
| attribute | f7 | units | String | none |
The information in the table above is also available in other file formats (.csv, .htmlTable, .itx, .json, .jsonlCSV1, .jsonlCSV, .jsonlKVP, .mat, .nc, .nccsv, .tsv, .xhtml) via a RESTful web service.