ERDDAP
Easier access to scientific data |
|
Brought to you by NOAA NMFS SWFSC ERD |
| Grid DAP Data | Sub- set | Table DAP Data | Make A Graph | W M S | Source Data Files | Title | Sum- mary | FGDC, ISO, Metadata | Back- ground Info | RSS | E | Institution | Dataset ID | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| data | graph | RV Sikuliaq : SENSOR_FLOAT_3_ARCHIVE |
| M | background
|
|
|
| sensor_float_3_archive |
| Row Type | Variable Name | Attribute Name | Data Type | Value |
|---|---|---|---|---|
| attribute | NC_GLOBAL | cdm_data_type | String | Other |
| attribute | NC_GLOBAL | creator_name | String | Oregon State University |
| attribute | NC_GLOBAL | creator_url | String | http://ceoas.oregonstate.edu![]() |
| attribute | NC_GLOBAL | infoUrl | String | http://ceoas.oregonstate.edu![]() |
| attribute | NC_GLOBAL | institution | String | Oregon State University |
| attribute | NC_GLOBAL | keywords | String | atmosphere, data, observations, ocean, vessel |
| attribute | NC_GLOBAL | license | String | The data may be used and redistributed for free but is not intended for legal use, since it may contain inaccuracies. Neither the data Contributor, ERD, NOAA, nor the United States Government, nor any of their employees or contractors, makes any warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, or assumes any legal liability for the accuracy, completeness, or usefulness, of this information. |
| attribute | NC_GLOBAL | sourceUrl | String | (source database) |
| attribute | NC_GLOBAL | summary | String | RCRV CORIOLIX |
| attribute | NC_GLOBAL | title | String | RV Sikuliaq : SENSOR_FLOAT_3_ARCHIVE |
| variable | time_raw | double | ||
| attribute | time_raw | ioos_category | String | Time |
| attribute | time_raw | long_name | String | Time Raw |
| attribute | time_raw | time_origin | String | 01-JAN-1970 00:00:00 |
| attribute | time_raw | units | String | seconds since 1970-01-01T00:00:00Z |
| variable | time | double | ||
| attribute | time | _CoordinateAxisType | String | Time |
| attribute | time | axis | String | T |
| attribute | time | ioos_category | String | Time |
| attribute | time | long_name | String | Time |
| attribute | time | standard_name | String | time |
| attribute | time | time_origin | String | 01-JAN-1970 00:00:00 |
| attribute | time | units | String | seconds since 1970-01-01T00:00:00Z |
| variable | sensor_id | String | ||
| attribute | sensor_id | ioos_category | String | Identifier |
| attribute | sensor_id | standard_name | String | xxxxxx |
| attribute | sensor_id | units | String | none |
| variable | p1 | double | ||
| attribute | p1 | ioos_category | String | Temperature |
| attribute | p1 | long_name | String | Thermosalinograph Temperature |
| attribute | p1 | sensor_description | String | TSG SBE 45_0455 : Sea-Bird Scientific (Sea-Bird Electronics) Sea-Bird SBE 45 MicroTSG thermosalinograph 45-0455 : Tech Stores |
| attribute | p1 | short_name | String | Temperature |
| attribute | p1 | standard_name | String | tempsz01 |
| attribute | p1 | units | String | degrees_C |
| variable | f1 | String | ||
| attribute | f1 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | f1 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | f1 | ioos_category | String | Temperature |
| attribute | f1 | long_name | String | Thermosalinograph Temperature Status Flag |
| attribute | f1 | short_name | String | Temperature Status Flag |
| attribute | f1 | standard_name | String | tempsz01_status_flag |
| attribute | f1 | units | String | none |
| variable | p2 | double | ||
| attribute | p2 | ioos_category | String | Salinity |
| attribute | p2 | long_name | String | Thermosalinograph Conductivity |
| attribute | p2 | sensor_description | String | TSG SBE 45_0399 : Sea-Bird Scientific (Sea-Bird Electronics) Sea-Bird SBE 45 MicroTSG thermosalinograph 45-0399 : Main Lab / Wet Wall |
| attribute | p2 | short_name | String | Conductivity |
| attribute | p2 | standard_name | String | cndcsg01 |
| attribute | p2 | units | String | S/m |
| variable | f2 | String | ||
| attribute | f2 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | f2 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | f2 | ioos_category | String | Salinity |
| attribute | f2 | long_name | String | Thermosalinograph Conductivity Status Flag |
| attribute | f2 | short_name | String | Conductivity Status Flag |
| attribute | f2 | standard_name | String | cndcsg01_status_flag |
| attribute | f2 | units | String | none |
| variable | p3 | double | ||
| attribute | p3 | ioos_category | String | Salinity |
| attribute | p3 | long_name | String | Thermosalinograph Salinity |
| attribute | p3 | sensor_description | String | TSG SBE 45_0455 : Sea-Bird Scientific (Sea-Bird Electronics) Sea-Bird SBE 45 MicroTSG thermosalinograph 45-0455 : Tech Stores |
| attribute | p3 | short_name | String | Salinity |
| attribute | p3 | standard_name | String | psalsu01 |
| variable | f3 | String | ||
| attribute | f3 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | f3 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | f3 | ioos_category | String | Salinity |
| attribute | f3 | long_name | String | Thermosalinograph Salinity Status Flag |
| attribute | f3 | short_name | String | Salinity Status Flag |
| attribute | f3 | standard_name | String | psalsu01_status_flag |
| attribute | f3 | units | String | none |
| variable | p4 | double | ||
| attribute | p4 | ioos_category | String | Physical Oceanography |
| attribute | p4 | long_name | String | Thermosalinograph Sound Velocity |
| attribute | p4 | sensor_description | String | TSG SBE 45_0455 : Sea-Bird Scientific (Sea-Bird Electronics) Sea-Bird SBE 45 MicroTSG thermosalinograph 45-0455 : Tech Stores |
| attribute | p4 | short_name | String | Sound Velocity |
| attribute | p4 | standard_name | String | svelca01 |
| attribute | p4 | units | String | m/s |
| variable | f4 | String | ||
| attribute | f4 | flag_notes | String | Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing. |
| attribute | f4 | flag_order | String | 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused, |
| attribute | f4 | ioos_category | String | Physical Oceanography |
| attribute | f4 | long_name | String | Thermosalinograph Sound Velocity Status Flag |
| attribute | f4 | short_name | String | Sound Velocity Status Flag |
| attribute | f4 | standard_name | String | svelca01_status_flag |
| attribute | f4 | units | String | none |
The information in the table above is also available in other file formats (.csv, .htmlTable, .itx, .json, .jsonlCSV1, .jsonlCSV, .jsonlKVP, .mat, .nc, .nccsv, .tsv, .xhtml) via a RESTful web service.