SVP TELE70_4016

Summary



TypeSSV
VendorTeledyne (Benthos)
ModelTeledyne Reson SVP 70 sound velocity profiler
S/N480083/2824016
CORIOLIX IDsvptele2824016
Inventory ID
Data ID
ClassFlowthrough
LocationCenterboard
Native Sample Rate1.0 Hz
UDP Port(s)53105 None
EnabledFalse
 
 
 

General Description



Teledyne Resin SVP70 Fixed-Mount sound velocity sensor.

 
 

Data Collection Specs



Native Data Feed At The Sensor
Signal Type Digital
Communication Type RS-232
Serial Details
Baud Rate 9600
Parity N
Stop Bits 1
Byte Size 8
Timeout (s) None
Polled Start Commands
Polled Serial Commands
Ethernet Details
MAC Address
IP Address
Protocol udp
Source File Details
Path
Filename
Native Data Format
Native Data Description Sample Data Line: svptele2824016 ssv_tele_cb 2023-02-05T00:11:55.7078Z 1437.712 ****** Field Description: Coriolix Sensor ID, LDS Logger ID, LDS Timestamp [UTC], Sound Velocity (m/s)
Native Data Type text
Start of Message Characters
End of Message Characters
Number of Fields to Trim 0
Sample Data Message $PSOS 123234, 1450.002,20.3,102.5,210,9,0,1<CR><LF>
Message Parser Format ['^(?P<speedofsoundinseawater_mpers>\d+\.\d+)$']
Data/Message ID
Data Processing
Data Processing Script NoTransformation
Data Rates
Native Sample Rate 1.0 Hz
Shipboard Network Packet Rate 1.0 Hz
Ship to Shore Rate None Hz
Data Storage & Access
Raw Data Ethernet Distribution
IP Address 10.3.0.255
Port 53105
Packet Size None
Transformed Data Ethernet Distribution
IP Address
Port None
OpenRVDAS Logger Mode file/db
EEZ Logger Mode off
InfluxDB Port None
Archive to Database True
Transmit Real-time Data to Shore True
Time Source
Source local_time_server
 

Parameters



Long Name Short Name Units Diagnostic
Speed of Sound - Water speed_of_sound_in_sea_water m/s False
 

Physical Sensor Specs



Operating Limits
Input Power 9.0 - 55.0 V DC
Ideal Power None V DC
Operating Current None - None mA @ None V DC
Analog Output None - 20 Hertz
Operating Flow Rate None - None ml s-1
Ideal Flow Rate None ml s-1
Operating Depth None - 6000 m
Operating Temperature -20 - 55 degree_C
Lamp Life None days
Response Time 0.000047 seconds
Additional Time Offset None seconds
Physical Status
Current Location on vessel
Current Status in use
Physical Condition excellent
Received 02/04/26.
Physical Configuration The sensor is in the flooded shoe at the bottom of the centerboard. Refer to wh300_xducer_depth or R2R Event Logger, to determine the depth of the centerboard.
Software Version
Software Configuration
Data Acquisition Device ID
Communication Type at the Data Acquisition Device
Data Acquisition Device Serial Port
Data Acquisition Device Analog/Digital Port(s)
Data Acquisition Device Modbus Unit/Device IDs
Data Acquisition Device Modbus Function Codes
Data Acquisition Device Modbus Registers
Data Acquisition Device Modbus Retransmit UDP Ports
Sensor Use Level primary
Enabled False
Vessel Installation Location
Vessel sikuliaq
Vessel Location Centerboard
Location Coordinates (meters) 19.7473, 2.1285, 6.0237
Sensor Orientation horizontal
Height Above Waterline (meters) -6.1761
Zero Line Reference (degrees from bow) None
Receives Filtered Water False
 

Maintenance & Support

Sensor Log

    Date (UTC)     Submitter     Event Type     Details        
May 09 2026 14:00:19     Naber, Daniel     sensor specs update     cal_recommended_freq_months changed from [12] to [24]    
May 09 2026 14:00:19     Naber, Daniel     sensor specs update     sensor_orientation changed from [vertical down] to [horizontal]    
May 09 2026 14:00:19     Naber, Daniel     sensor specs update     configuration changed from [] to [The sensor is in the ... of the centerboard.]    
May 09 2026 14:00:19     Naber, Daniel     sensor specs update     condition_details changed from [Received 02/04/26. T ... e by Dan - 05/04/26.] to [Received 02/04/26.]    
May 09 2026 14:00:19     Naber, Daniel     sensor specs update     current_status changed from [testing in progress] to [in use]    
May 04 2026 15:52:43     Soltis, Joseph     sensor specs update     last_cal_date changed from [2013-11-21 00:00:00+00:00] to [2024-10-21]    
May 04 2026 15:52:43     Soltis, Joseph     sensor specs update     location_text changed from [Tech Stores] to [Centerboard]    
May 04 2026 15:52:43     Soltis, Joseph     sensor specs update     configuration changed from [The sensor is in the ... of the centerboard.] to []    
May 04 2026 15:52:43     Soltis, Joseph     sensor specs update     condition_details changed from [Outputting zero's al ... e - SKQ202519S - CJG] to [Received 02/04/26. T ... e by Dan - 05/04/26.]    
May 04 2026 15:52:43     Soltis, Joseph     sensor specs update     condition changed from [inoperable] to [excellent]    
May 04 2026 15:52:43     Soltis, Joseph     sensor specs update     current_status changed from [unavailable] to [testing in progress]    
May 04 2026 15:52:43     Soltis, Joseph     sensor specs update     acquire_condition changed from [] to [excellent]    
May 04 2026 15:52:43     Soltis, Joseph     sensor specs update     purchase_date changed from [None] to [2026-03-30]    
May 04 2026 15:52:43     Soltis, Joseph     sensor specs update     temperature_max_celsius changed from [None] to [55]    
May 04 2026 15:52:43     Soltis, Joseph     sensor specs update     temperature_min_celsius changed from [None] to [-20]    
May 04 2026 15:52:43     Soltis, Joseph     sensor specs update     depth_max_meters changed from [None] to [6000]    
May 04 2026 15:52:43     Soltis, Joseph     sensor specs update     analog_units changed from [] to [Hertz]    
May 04 2026 15:52:43     Soltis, Joseph     sensor specs update     analog_max changed from [None] to [20]    
May 04 2026 15:52:43     Soltis, Joseph     sensor specs update     power_max_volts changed from [26.0] to [55.0]    
May 04 2026 15:52:43     Soltis, Joseph     sensor specs update     power_min_volts changed from [8.0] to [9.0]    
May 04 2026 15:52:43     Soltis, Joseph     sensor specs update     sample_data_message changed from [1437.712] to [$PSOS 123234, 1450.0 ... .5,210,9,0,1<CR><LF>]    
May 04 2026 15:52:43     Soltis, Joseph     sensor specs update     native_data_description changed from [Sample Data Line: s ... Sound Velocity (m/s)] to [Sample Data Line: s ... Sound Velocity (m/s)]    
May 04 2026 15:52:43     Soltis, Joseph     sensor specs update     sensor_ip changed from [10.3.0.105] to []    
May 04 2026 15:52:43     Soltis, Joseph     sensor specs update     description changed from [AML Oceanographic Mi ... und velocity sensor.] to [Teledyne Resin SVP70 ... und velocity sensor.]    
May 04 2026 15:52:43     Soltis, Joseph     sensor specs update     model changed from [AML Oceanographic Micro SV sound velocity probe] to [Teledyne Reson SVP 70 sound velocity profiler]    
May 04 2026 15:52:43     Soltis, Joseph     sensor specs update     vendor changed from [AML Oceanographic ] to [Teledyne (Benthos)]    
May 04 2026 15:52:43     Soltis, Joseph     sensor specs update     sensor_name changed from [SVP AML_3298] to [SVP TELE70_4016]    
May 04 2026 14:19:39     Soltis, Joseph     new sensor     Copied sensor metadata from sndvel203298 with modified serial number 480083/2824016.    
 
Calibration & Maintenance

Frequency Last Completed Next Due
Maintenance A:
 
Maintenance B:
 
Maintenance C:
 
Calibration
  24 months Oct 21 2024 Oct 21 2026
Recommended Replacement
 
Warranty
 
 
Calibration Files

Date Version Author Type Document Access
Oct 21 2024        Teledyne   cal_file   20241021_SVP70_2824016_calibration.pdf
 
 
User Guides & Documents

Date Version Author Type Document Access
May 04 2026        JS   datasheet   Product Leaflet
May 04 2026        JS   brochure   Quick ref guide
May 04 2026        JS   reference_sheet   Technical Spec Sheet
May 04 2026        JS   sensor_image   Teledyne Reson SVP 70 main image
 
 
Ownership

Quantity Value
Owner UAF
Responsible Party UAF Marine Technicians
Inventory ID
Purchase Date Mar 30 2026
Acquire Date
Acquire Condition excellent
End/Lost Ownership Date
 
Vendor Support

Support Type Details
Company Teledyne (Benthos)
Website www.teledynemarine.com
Phone +1 508-563-1000
Email benthos@teledyne.com
Shipping
 
Copyright Notice: All sensor-specific images and documentation on this page are copyright of the vendor.
 
 
OSU logo NSF logo RCRV logo
RCRV Datapresence and Engineering Support Center
Oregon State University
Corvallis, OR 97331, USA
coriolix_support@oregonstate.edu