Pyranometer SMP21_0196

Summary



TypePyranometer
VendorKipp and Zonen (OTT Hydromet)
ModelKipp and Zonen SMP21 pyranometer
S/N200196
ID Prefixpyrano
CORIOLIX IDpyrano200196
ClassAtmospheric
LocationTech Stores
Conditionexcellent
ConfigurationMounted in CV4 Ventilation Unit
Native Sample Rate1.0 Hz
UDP Port(s)53137 None
EnabledFalse
 


Image Not Available
 
 

General Description



Pyranometer, SMP21-V, with digital interface for meteorological networks, reference measurements in extreme climates, polar or arid.

 
 

Data Collection Specs

Native Data Feed
Signal Type Digital
Communication Type RS-485
Serial Details
Baud Rate 19200
Parity E
Stop Bits 1
Byte Size 8
Timeout (s) None
Polled Start Commands None
Polled Serial Commands
Ethernet Details
MAC Address
IP Address 10.3.0.137
Protocol udp
Source File Details
Path
Filename
Native Data Format
Native Data Description Modbus RTU Protocol. Example Data Line: radiom200196 rad_smp21 2022-11-03T00:00:02.7877Z 605,195,14.1,-0.5,12.0,1,1,0 ***** Field Descriptions: Coriolix Sensor ID, LDS Logger ID, LDS Time Stamp [UTC], Device_Type: [605 = smp21], Serial_Num: last three digits, Rad[W/m2]: temperature compensated short wave radiation, Body_Temp[C], Ext_Volts, Scale_Factor: range and scale factor (determines number of decimal places), Op_Mode: [1 = normal], Status_Flag: [0 = normal]
Native Data Type text
Start of Message Characters
End of Message Characters
Sample Data Message 605,195,14.1,-0.5,12.0,1,1,0
Message Parser Format ['^\d+,\d+,(?P<rad>\-?\d+\.\d+),(?P<body_temp>\-?\d+\.\d+),(?P<ext_volts>\d+\.\d+),\d+,(?P<op_mode>\d+),(?P<status>\d+)$']
Data Processing
Data Processing Script NoTransformation
Data Rates
Native Sample Rate 1.0 Hz
Shipboard Network Packet Rate 1.0 Hz
Ship to Shore Rate None Hz
Data Storage & Access
Raw Data Ethernet Distribution
IP Address 10.3.0.255
Port 53137
Packet Size None
Transformed Data Ethernet Distribution
IP Address
Port None
Archive to Database True
Transmit Real-time Data to Shore True
Time Source
Source local_time_server
 

Parameters


Quantity body_temp (degrees_C) ext_volts (V) op_mode ( ) rad (W/m2) status ( )
Plot Color
 
 
 
 
 
Parameter Full Name Sensor Body Temperature External Voltage op_mode Radiation Status Flag
Parameter Short Name body_temp ext_volts op_mode rad status
Parameter Standard Name CTMPZZ02 VOLTELEC STATFLIR CSLRR101 STATFLIR
SAMOS Data Category Shortwave Radiation
Description sensor body temperature in degrees Celsius externally supplied voltage reading Operational mode [1 = normal] temperature compensated short wave radiation in Watts per meter squared sensor status flags [0 = normal]
Processing Status raw raw raw internally derived raw
Processing Symbol body_temp ext_volts op_mode rad status
Diagnostic True True True False True
IOOS Category Meteorology Other Meteorology Meteorology Other
Units degrees_C V W/m2
Data Type float float int float int
Gross Minimum Value None degrees_C None V None None W/m2 None
Gross Maximum Value None degrees_C None V None None W/m2 None
Recommended Minimum Value None degrees_C None V None None W/m2 None
Recommended Maximum Value None degrees_C None V None None W/m2 None
Global Minimum Value None degrees_C None V None None W/m2 None
Global Maximum Value None degrees_C None V None None W/m2 None
Local Minimum Value None degrees_C None V None None W/m2 None
Local Maximum Value None degrees_C None V None None W/m2 None
Lower Detection Limit None degrees_C None V None None W/m2 None
Saturated Value None degrees_C None V None None W/m2 None
Bad Data Value None degrees_C None V None None W/m2 None
Resolution None degrees_C None V None None W/m2 None
Accuracy +/- None degrees_C +/- None V +/- None +/- None W/m2 +/- None
Precision None degrees_C None V None None W/m2 None
Binning Type linear linear spot linear spot
Online Display Format 4.2f 4.2f 4.2f 4.2f 4.2f
Logging Modes
 

Physical Sensor Specs

Operating Limits
Input Power 3.0 - 30.0 V DC
Ideal Power None V DC
Operating Current None - 4.58 mA @ 12.0 V DC
Analog Output 0 - 1 Volts
Operating Flow Rate None - None ml s-1
Ideal Flow Rate None ml s-1
Operating Depth None - None m
Operating Temperature -40 - 70 degree_C
Lamp Life None days
Response Time 2.0 seconds
Additional Time Offset None seconds
Physical Status
Current Location on vessel
Current Status not in use
Physical Condition excellent
Physical Configuration Mounted in CV4 Ventilation Unit
Software Version
Software Configuration
Data Acquisition Device ID
Data Acquisition Device Serial Port
Data Acquisition Device Analog/Digital Port(s)
Data Acquisition Device Modbus Unit None
Sensor Use Level
Enabled False
Vessel Installation Location
Vessel sikuliaq
Vessel Location Tech Stores
Location Coordinates (meters)
Sensor Orientation vertical up
Height Above Waterline (meters) 9.3
Zero Line Reference (degrees from bow) None
Receives Filtered Water False
 

Maintenance & Support

Sensor Log

    Date (UTC)     Submitter     Event Type     Details        
Feb 13 2024 20:24:55     Nahorniak, Jasmine     new parameter     Copied status ( ) parameter metadata from pyrano200195.    
Feb 13 2024 20:24:04     Nahorniak, Jasmine     new parameter     Copied rad (W/m2) parameter metadata from pyrano200195.    
Feb 13 2024 20:23:47     Nahorniak, Jasmine     new parameter     Copied op_mode ( ) parameter metadata from pyrano200195.    
Feb 13 2024 20:23:31     Nahorniak, Jasmine     new parameter     Copied ext_volts (V) parameter metadata from pyrano200195.    
Feb 13 2024 20:23:10     Nahorniak, Jasmine     new parameter     Copied body_temp (degrees_C) parameter metadata from pyrano200195.    
Feb 13 2024 20:22:24     Nahorniak, Jasmine     renamed sensor     Changed sensor ID from radiom200196 to pyrano200196.    
Feb 13 2024 20:16:47     Nahorniak, Jasmine     sensor specs update     processing_script changed from [] to [NoTransformation]    
Feb 13 2024 20:16:47     Nahorniak, Jasmine     sensor specs update     sensor_prefix changed from [] to [pyrano]    
Mar 16 2023 00:03:18     Naber, Daniel     sensor specs update     response_time_seconds changed from [None] to [2.0]    
Mar 16 2023 00:03:18     Naber, Daniel     sensor specs update     temperature_max_celsius changed from [None] to [70]    
Mar 16 2023 00:03:18     Naber, Daniel     sensor specs update     temperature_min_celsius changed from [None] to [-40]    
Mar 16 2023 00:03:18     Naber, Daniel     sensor specs update     analog_units changed from [] to [Volts]    
Mar 16 2023 00:03:18     Naber, Daniel     sensor specs update     analog_max changed from [None] to [1]    
Mar 16 2023 00:03:18     Naber, Daniel     sensor specs update     analog_min changed from [None] to [0]    
Mar 16 2023 00:03:18     Naber, Daniel     sensor specs update     current_reference_volts changed from [None] to [12.0]    
Mar 16 2023 00:03:18     Naber, Daniel     sensor specs update     current_max_milliamps changed from [None] to [4.58]    
Mar 16 2023 00:03:18     Naber, Daniel     sensor specs update     power_current_type changed from [AC] to [DC]    
Mar 16 2023 00:03:18     Naber, Daniel     sensor specs update     power_max_volts changed from [None] to [30.0]    
Mar 16 2023 00:03:18     Naber, Daniel     sensor specs update     power_min_volts changed from [None] to [3.0]    
Mar 16 2023 00:03:17     Naber, Daniel     sensor specs update     description changed from [Pyranometer with dig ... ates, polar or arid.] to [Pyranometer, SMP21-V ... ates, polar or arid.]    
Mar 11 2023 07:05:31     Naber, Daniel     sensor specs update     packet_rate_hz changed from [None] to [1.0]    
Mar 11 2023 07:05:31     Naber, Daniel     sensor specs update     transmit_port changed from [None] to [53137]    
Mar 11 2023 07:05:31     Naber, Daniel     sensor specs update     transmit_ip changed from [] to [10.3.0.255]    
Mar 11 2023 07:05:31     Naber, Daniel     sensor specs update     time_source changed from [vessel_time_server] to [local_time_server]    
Mar 11 2023 07:05:31     Naber, Daniel     sensor specs update     height_above_waterline changed from [None] to [9.3]    
Mar 11 2023 07:05:31     Naber, Daniel     sensor specs update     sensor_orientation changed from [horizontal] to [vertical up]    
Mar 11 2023 07:05:31     Naber, Daniel     sensor specs update     text_regex_format changed from [] to [['^\d+,\d+,(?P<rad>\ ... ),(?P<status>\d+)$']]    
Mar 11 2023 07:05:31     Naber, Daniel     sensor specs update     sample_data_message changed from [] to [605,195,14.1,-0.5,12.0,1,1,0]    
Mar 11 2023 07:05:31     Naber, Daniel     sensor specs update     native_type changed from [] to [text]    
Mar 11 2023 07:05:31     Naber, Daniel     sensor specs update     native_data_description changed from [Modbus RTU Protocol] to [Modbus RTU Protocol. ... s_Flag: [0 = normal]]    
Mar 11 2023 07:05:31     Naber, Daniel     sensor specs update     sample_rate_hz changed from [None] to [1.0]    
Mar 11 2023 07:05:31     Naber, Daniel     sensor specs update     sensor_ethernet_protocol changed from [] to [udp]    
Mar 11 2023 07:05:31     Naber, Daniel     sensor specs update     sensor_ip changed from [] to [10.3.0.137]    
Mar 11 2023 07:05:31     Naber, Daniel     sensor specs update     serial_bytesize changed from [] to [8]    
Mar 11 2023 07:05:31     Naber, Daniel     sensor specs update     serial_stop_bits changed from [] to [1]    
Mar 11 2023 07:05:31     Naber, Daniel     sensor specs update     serial_parity changed from [] to [E]    
Mar 11 2023 07:05:31     Naber, Daniel     sensor specs update     serial_baud_rate changed from [] to [19200]    
Oct 21 2022 08:21:56     Kopka, Krystian     sensor specs update     location_text changed from [] to [Tech Stores]    
Oct 21 2022 00:40:00     Kopka, Krystian     sensor specs update     use_level changed from [spare] to []    
May 23 2022 23:16:59     Greto, Carmen     new sensor     Initial submission of sensor metadata.    
 
Calibration & Maintenance

Frequency Last Completed Next Due
Maintenance A: Clear Dome of Snow and Moisture
  1 days
Maintenance B:
 
Maintenance C:
 
Calibration
  60 months Jul 15 2020 Jul 15 2025
Recommended Replacement
 
Warranty
 
 
Calibration Files

Date Version Author Type Document Access
Jul 15 2020           cal_file   Pyranometer SMP21_0196 CAL_PDF
 
 
User Guides & Documents

Date Version Author Type Document Access
 
 
Ownership

Quantity Value
Owner UAF
Responsible Party UAF Marine Technicians
Purchase Date Jan 01 2021
Acquire Date
Acquire Condition
End/Lost Ownership Date
 
Vendor Support

Support Type Details
Company Kipp and Zonen (OTT Hydromet)
Website https://www.kippzonen.com/
Phone +1 703 406 2800
Email kipp.usa@kippzonen.com
Shipping OTT Hydromet, 22400 Davis Dr.,Sterling, VA 20164, USA
 
Copyright Notice: All sensor-specific images and documentation on this page are copyright of the vendor.
 
 
OSU logo NSF logo RCRV logo
RCRV Datapresence and Engineering Support Center
Oregon State University
Corvallis, OR 97331, USA