pCO2_Apollo

Summary



TypepCO2
VendorApollo Scitech
ModelApollo SciTech AS-P3 combined pCO2 analyser and underway system
S/N2101-OSU
CORIOLIX IDpcotwo002101
Inventory ID
Data ID
ClassFlowthrough
LocationNot Applicable
Native Sample Rate1.0 Hz
UDP Port(s)53155 59155
EnabledFalse
 
 
 

General Description



The Apollo ASP3 provides sea surface and atmospheric pCO2. An integrated SBE-45 thermosalinograph supports temperature and salinity correction, while the addition of 1-5 calibration gases ensures compensation with reference to known standards. Surface seawater travels through a showerhead equilibrator with a response time of 2 minutes. The equilibrated air is then dried and analyzed with an infrared or lased-based CO2 gas analyzer, the Li Cor LI-7815.

 
 

Data Collection Specs



Native Data Feed At The Sensor
Signal Type Digital
Communication Type Ethernet
Serial Details
Baud Rate
Parity
Stop Bits
Byte Size
Timeout (s) None
Polled Start Commands
Polled Serial Commands
Ethernet Details
MAC Address 50:81:40:FC:DF:F3
IP Address 10.3.0.45
Protocol udp
Source File Details
Path
Filename
Native Data Format
Native Data Description Data comes derived from the sensor, measurements are provided in calibrated and corrected format from the sensor. Data is broadcast over UDP and output in a JSON format.
Native Data Type text
Start of Message Characters
End of Message Characters
Number of Fields to Trim 0
Sample Data Message [#v2.0[\#2024/07/28 16:43:28\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#Manual\#,\#Air\#,\#NaN\#,\#NaN\#,\#495.704\#,\#11.0068\#,\#39.9202\#,\#54.9995\#,\#0\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#18.3755\#,\#0.10631\#,\#0.6092\#,\#102.00\#,\#1006.73\#,\#16.66\#,\#0.01\#,\#6.66\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#OFF | OFF\#,\#\#,\#180\#,\#100\#,\#Continuous\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#]#]
Message Parser Format ['^\[\Wv\d+\.\d+\[\W\W(?P<sensordatetime_unitless>\d\d\d\d/\d\d/\d\d \d\d:\d\d:\d\d)\W\W,\W\W(?P<gps_datetime>[^,]*)\W\W,\W\W(?P<latitude>[^,]*)\W\W,\W\W(?P<longitude>[^,]*)\W\W,\W\W(?P<garmin_status>[^,]*)\W\W,\W\W(?P<garmin_datetime>[^,]*)\W\W,\W\W(?P<garmin_latitude>[^,]*)\W\W,\W\W(?P<garmin_longitude>[^,]*)\W\W,\W\W(?P<ship_gps_format>[^,]*)\W\W,\W\W(?P<ship_time>[^,]*)\W\W,\W\W(?P<ship_latitude>[^,]*)\W\W,\W\W(?P<ship_longitude>[^,]*)\W\W,\W\W(?P<sensormode_unitless>\w+)\W\W,\W\W(?P<samplesource_unitless>[\w\s\-\.]+)\W\W,\W\W(?P<xco2stddev_ppm>[Na\d\.]+)\W\W,\W\W(?P<xco2_ppm>[\-\d\.\w]*)\W\W,\W\W(?P<xco2uncorr_ppm>\-?\d+\.\d+)\W\W,\W\W(?P<watervapor_1perml>\-?\d+\.\d+)\W\W,\W\W(?P<cavitypressure_kpa>\-?\d+\.\d+)\W\W,\W\W(?P<cavitytemperature_degreesc>\-?\d+\.\d+)\W\W,\W\W(?P<diagnosticcode_unitless>\d+)\W\W,(?P<li_7810>(\W\W[^,]*\W\W,){6})(?P<li_7000>(\W\W[^,]*\W\W,){7})(?P<li_850>(\W\W[^,]*\W\W,){6})(?P<picarro>(\W\W[^,]*\W\W,){6})\W\W(?P<seawatertemperature_degreesc>(\-?\d+\.\d+)?)\W\W,\W\W(?P<seawaterconductivity_sperm>(\-?\d+\.\d+)?)\W\W,\W\W(?P<seawaterpracticalsalinity_unitless>(\-?\d+\.\d+)?)\W\W,\W\W(?P<gasflowrate_mlperminute>\-?\d+\.\d+)\W\W,\W\W(?P<equilibratorpressure_mbar>(\-?\d+\.\d+)?)\W\W,\W\W(?P<equilibratortemperature_degreesc>(\-?\d+\.\d+)?)\W\W,\W\W(?P<waterflowrate_lperminute>(\-?\d+\.\d+)?)\W\W,\W\W(?P<coolingpadtemperature_degreesc>(\-?\d+\.\d+)?)\W\W,(?P<fluorescence>(\W\W[^,]*\W\W,){3})(?P<oxygen>(\W\W[^,]*\W\W,){5})(?P<durafet>(\W\W[^,]*\W\W,){2})\W\W(?P<sensoroperator_unitless>(\w*)?)\W\W,\W\W(?P<note>[^,]*)\W\W,\W\W(?P<overflowalarm_unitless>(\w*))\s?\|?\s?(?P<shutoffvalvealarm_unitless>(\w*))\W\W,\W\W(?P<measurementcount_unitless>\d*)\s?\|?\s?(?P<measurementstddev_ppm>[\d\.]*)\W\W,\W\W(?P<measurementinterval_s>\d*)\s?\|?\s?(?P<purgeinterval_s>\d*)\W\W,\W\W(?P<flowrate_mlperminute>\-?\d*)\s?\|?\s?(?P<purgeflowrate_mlperminute>\-?\d*)\W\W,\W\W(?P<testtype_unitless>\w+)\W\W,(?P<weather_station>(\W\W[^,]*\W\W,){9})(?P<li_7820>(\W\W[^,]*\W\W,){4}\W\W[^,]*\W\W)\]\W\]$']
Data/Message ID
Data Processing
Data Processing Script pCO2
Data Rates
Native Sample Rate 1.0 Hz
Shipboard Network Packet Rate 1.0 Hz
Ship to Shore Rate 1.0 Hz
Data Storage & Access
Raw Data Ethernet Distribution
IP Address 10.3.0.255
Port 53155
Packet Size None
Transformed Data Ethernet Distribution
IP Address 127.0.0.1
Port 59155
OpenRVDAS Logger Mode file/db
EEZ Logger Mode off
InfluxDB Port None
Archive to Database True
Transmit Real-time Data to Shore True
Time Source
Source local_time_server
 

Parameters



Long Name Short Name Units Diagnostic
Partial Pressure of Carbon Dioxide in Air air_pco2 uatm False
Cavity Pressure cavity_pressure kPa True
Cavity Temperature cavity_temperature degrees_C True
Cooling Pad Temperature cooling_pad_temperature degrees_C True
Diagnostic Code diagnostic_code unitless True
Partial Pressure of Carbon Dioxide in the Equilibrator equilibrator_pco2 uatm False
Equilibrator Pressure equilibrator_pressure mbar True
Equilibrator Temperature equilibrator_temperature degrees_C True
Flow Rate flow_rate ml/minute True
Gas Flow Rate gas_flow_rate ml/minute True
GPS Datetime gps_datetime unitless True
Latitude latitude degrees False
Longitude longitude degrees False
Number of Measurements measurement_count unitless True
Measurement Interval measurement_interval s True
Measurement Standard Deviation measurement_stddev ppm True
Overflow Alarm overflow_alarm unitless True
Purge Flow Rate purge_flow_rate ml/minute True
Purge Interval purge_interval s True
Sample Source sample_source unitless True
Sea Water Electrical Conductivity sea_water_conductivity S/m True
Partial Pressure of Carbon Dioxide in Seawater sea_water_pco2 uatm False
Sea Water Practical Salinity sea_water_practical_salinity unitless False
Sea Water Temperature sea_water_temperature degrees_C False
Sensor Datetime sensor_datetime unitless True
Sensor Mode sensor_mode unitless True
Operator sensor_operator unitless True
Shutoff Valve Alarm shutoff_valve_alarm unitless True
Test Type test_type unitless True
Water Flow Rate water_flow_rate l/minute True
Water Vapor water_vapor 1/ml False
Water Vapor Pressure water_vapor_pressure atm False
xCO2 xco2 ppm False
xCO2 Standard Deviation xco2_stddev ppm True
xCO2 Uncorrected xco2_uncorr ppm True
 

Physical Sensor Specs



Operating Limits
Input Power 115.0 - 120.0 V AC
Ideal Power 115.0 V AC
Operating Current None - None mA @ None V AC
Analog Output None - None
Operating Flow Rate 63.0 - 83.0 ml s-1
Ideal Flow Rate 67.0 ml s-1
Operating Depth 0 - 0 m
Operating Temperature -25 - 45 degree_C
Lamp Life None days
Response Time 120.0 seconds
Additional Time Offset 1.0 seconds
Physical Status
Current Location no longer in possession
Current Status unavailable
Physical Condition good
Physical Configuration Gas regulator with stable delivery pressure of 15 psi (1 atm), high-quality 2-stage regulators with full delivery pressure range of 30 to 50 psi, type CGA-590 for air-balanced tanks, 3/4" PVC pipe or
Software Version AS-pco2-RV3.0
Software Configuration
Data Acquisition Device ID
Communication Type at the Data Acquisition Device
Data Acquisition Device Serial Port
Data Acquisition Device Analog/Digital Port(s)
Data Acquisition Device Modbus Unit/Device IDs
Data Acquisition Device Modbus Function Codes
Data Acquisition Device Modbus Registers
Data Acquisition Device Modbus Retransmit UDP Ports
Sensor Use Level
Enabled False
Vessel Installation Location
Vessel sikuliaq
Vessel Location Not Applicable
Location Coordinates (meters)
Sensor Orientation not applicable
Height Above Waterline (meters) None
Zero Line Reference (degrees from bow) None
Receives Filtered Water False
 

Maintenance & Support

Sensor Log

    Date (UTC)     Submitter     Event Type     Details        
Apr 13 2026 20:00:23     Nahorniak, Jasmine     parameter specs update     data_fieldname changed from [value] to []    
Apr 13 2026 20:00:23     Nahorniak, Jasmine     parameter specs update     convention changed from [degrees (+W/-E)] to [degrees (-W/+E)]    
Apr 13 2026 19:57:44     Nahorniak, Jasmine     parameter specs update     display_format changed from [3.2f] to []    
Apr 13 2026 19:57:44     Nahorniak, Jasmine     parameter specs update     data_fieldname changed from [value] to []    
Apr 13 2026 19:57:44     Nahorniak, Jasmine     parameter specs update     convention changed from [] to [degrees (+W/-E)]    
Apr 13 2026 19:57:44     Nahorniak, Jasmine     parameter specs update     processing_symbol changed from [longitude] to []    
Apr 13 2026 19:57:31     Nahorniak, Jasmine     parameter specs update     display_format changed from [3.2f] to []    
Apr 13 2026 19:57:31     Nahorniak, Jasmine     parameter specs update     data_fieldname changed from [value] to []    
Apr 13 2026 19:57:31     Nahorniak, Jasmine     parameter specs update     convention changed from [] to [degrees (+N/-S)]    
Apr 13 2026 19:57:31     Nahorniak, Jasmine     parameter specs update     processing_symbol changed from [latitude] to []    
Oct 22 2025 22:25:10     Nahorniak, Jasmine     sensor specs update     retransmit_ip changed from [10.3.0.36] to [127.0.0.1]    
Oct 22 2025 19:52:22     Nahorniak, Jasmine     sensor specs update     retransmit_port changed from [None] to [59155]    
Oct 22 2025 19:52:22     Nahorniak, Jasmine     sensor specs update     retransmit_ip changed from [] to [10.3.0.36]    
Nov 06 2024 16:08:11     Greto, Carmen     sensor specs update     use_level changed from [secondary] to []    
Nov 06 2024 16:08:11     Greto, Carmen     sensor specs update     location_text changed from [Wet Lab] to [Not Applicable]    
Nov 06 2024 16:08:11     Greto, Carmen     sensor specs update     enabled changed from [True] to [False]    
Nov 06 2024 16:08:11     Greto, Carmen     sensor specs update     current_status changed from [in use] to [unavailable]    
Nov 06 2024 16:08:11     Greto, Carmen     sensor specs update     current_location changed from [installed] to [no longer in possession]    
Aug 12 2024 19:00:00     Black, Ian     diagnosis     The Apollo data are now stable and integrated with the calibration standards. Data collected prior to this timestamp was used to diagnose sensor issues and should be considered bad/experimental.    
Aug 12 2024 18:45:59     Black, Ian     sensor specs update     current_status changed from [testing in progress] to [in use]    
Aug 09 2024 19:00:00     Black, Ian     issue     The LI-7815 is reporting negative values, which should be physically impossible. Tests are being performed to diagnose this issue.    
Aug 09 2024 18:00:00     Black, Ian     test     The 418.9ppm was applied to the Apollo after testing for gas line leaks.    
Aug 04 2024 21:23:37     Black, Ian     sensor specs update     maintenance_C_freq_days changed from [None] to [0]    
Aug 04 2024 21:23:37     Black, Ian     sensor specs update     maintenance_C_text changed from [test001] to [Freshwater Flush]    
Aug 04 2024 21:23:37     Black, Ian     sensor specs update     maintenance_B_freq_days changed from [None] to [3]    
Aug 04 2024 21:23:37     Black, Ian     sensor specs update     maintenance_B_text changed from [] to [Secondary Filter Check]    
Aug 04 2024 21:23:37     Black, Ian     sensor specs update     maintenance_A_text changed from [Filter Check] to [Primary Filter Check]    
Aug 04 2024 21:23:37     Black, Ian     sensor specs update     condition changed from [excellent] to [good]    
Aug 04 2024 21:23:37     Black, Ian     sensor specs update     depth_max_meters changed from [None] to [0]    
Aug 04 2024 21:23:37     Black, Ian     sensor specs update     depth_min_meters changed from [None] to [0]    
Aug 04 2024 21:23:37     Black, Ian     sensor specs update     flow_rate_ideal_mls changed from [63.0] to [67]    
Aug 04 2024 21:23:37     Black, Ian     sensor specs update     flow_rate_min_mls changed from [67.0] to [63]    
Aug 04 2024 21:23:37     Black, Ian     sensor specs update     description changed from [Flowthrough measurem ... the Li Cor LI-7815.] to [The Apollo ASP3 prov ... the Li Cor LI-7815.]    
Aug 02 2024 17:00:00     Black, Ian     change of use level     Data collected by the Apollo prior to this timestamp and until another change in use level should be considered experimental and likely does not reflect natural changes.    
Aug 02 2024 17:00:00     Black, Ian     test     The Apollo ASP3 was turned on with seawater-air cycles only until the LDEO pCO2 system has the new calibration gas installed and is tested with satisfaction.    
Jul 31 2024 18:01:00     Black, Ian     software update     Users may recalculate bad air_pco2 from CORIOLIX output by using air xCO2, barometric pressure from a shipside source, and water vapor pressure calculated using the intake SBE 38 and SBE45.    
Jul 31 2024 18:00:00     Black, Ian     software update     An issue with the air_pco2 value calculation was identified. The incorrect units were used for pressure. air_pco2 data prior to this timestamp are considered bad. A patch was pushed to fix this issue.    
Jul 30 2024 20:01:00     Black, Ian     issue     The Apollo sampling routine has been disabled until we can determine the optimal standard sampling pattern and verify there are no more standard leaks. Priority is to keep the LDEO running.    
Jul 30 2024 20:00:00     Black, Ian     issue     The 385ppm standard drained overnight. There is concern of a leak and that the Apollo may be drawing more standard than anticipated. The standards to the Apollo have been closed off.    
Jul 29 2024 06:02:10     Black, Ian     sensor specs update     warranty_end_date changed from [None] to [2026-06-30 00:00:00+00:00]    
Jul 29 2024 06:02:10     Black, Ian     sensor specs update     replacement_date changed from [None] to [2025-06-30 00:00:00+00:00]    
Jul 29 2024 06:02:10     Black, Ian     sensor specs update     last_cal_date changed from [None] to [2024-07-15 00:00:00+00:00]    
Jul 29 2024 06:02:10     Black, Ian     sensor specs update     cal_recommended_freq_months changed from [None] to [24]    
Jul 29 2024 06:02:10     Black, Ian     sensor specs update     maintenance_A_freq_days changed from [None] to [1]    
Jul 29 2024 06:02:10     Black, Ian     sensor specs update     maintenance_A_text changed from [] to [Filter Check]    
Jul 29 2024 06:02:10     Black, Ian     sensor specs update     time_source changed from [] to [local_time_server]    
Jul 28 2024 18:55:34     Nahorniak, Jasmine     renamed sensor     Changed sensor ID from pcotwo002202 to pcotwo002101.    
Jul 28 2024 18:51:45     Black, Ian     sensor specs update     sensor_orientation changed from [] to [not applicable]    
Jul 28 2024 18:51:45     Black, Ian     sensor specs update     software_version changed from [AS-pco2-RV2.0] to [AS-pco2-RV3.0]    
Jul 28 2024 18:51:45     Black, Ian     sensor specs update     current_status changed from [calibration in progress] to [testing in progress]    
Jul 28 2024 18:51:45     Black, Ian     sensor specs update     power_ideal_volts changed from [None] to [115.0]    
Jul 27 2024 21:49:31     Race, Julian     sensor specs update     sensor_ip changed from [10.3.0.155] to [10.3.0.45]    
Jul 27 2024 21:44:28     Race, Julian     sensor specs update     enabled changed from [False] to [True]    
Jul 27 2024 21:44:28     Race, Julian     sensor specs update     serial_number changed from [2202-OSU] to [2101-OSU]    
Jul 27 2024 14:40:04     Greto, Carmen     sensor specs update     location_text changed from [Main Lab] to [Wet Lab]    
Jul 27 2024 14:40:04     Greto, Carmen     sensor specs update     current_location changed from [RDESC] to [installed]    
Jul 27 2024 14:38:49     Greto, Carmen     sensor specs update     sensor_name changed from [pCO2] to [pCO2_Apollo]    
Jul 26 2024 12:00:00     Black, Ian     installation     Sensor was installed in the SKQ Wet Lab.    
Jul 02 2024 22:38:36     Nahorniak, Jasmine     sensor specs update     retransmit_port changed from [40325] to [None]    
Jul 02 2024 22:38:36     Nahorniak, Jasmine     sensor specs update     retransmit_ip changed from [172.16.40.255] to []    
Jul 02 2024 22:38:36     Nahorniak, Jasmine     sensor specs update     transmit_port changed from [30325] to [53155]    
Jul 02 2024 22:38:36     Nahorniak, Jasmine     sensor specs update     transmit_ip changed from [172.16.30.29] to [10.3.0.255]    
Jul 02 2024 22:38:36     Nahorniak, Jasmine     sensor specs update     sensor_ip changed from [170.16.30.95] to [10.3.0.155]    
Jul 02 2024 18:41:08     Nahorniak, Jasmine     sensor specs update     vendor changed from [Not Applicable] to [Apollo Scitech]    
Jul 02 2024 17:26:28     Nahorniak, Jasmine     sensor specs update     use_level changed from [primary] to [secondary]    
Jul 02 2024 17:26:28     Nahorniak, Jasmine     sensor specs update     vessel changed from [Taani] to [Sikuliaq]    
Jul 02 2024 17:26:28     Nahorniak, Jasmine     sensor specs update     vendor changed from [Apollo Scitech] to [Not Applicable]    
 
Calibration & Maintenance

Frequency Last Completed Next Due
Maintenance A: Primary Filter Check
  1 days
Maintenance B: Secondary Filter Check
  3 days
Maintenance C: test001
 
Calibration
  24 months Jul 15 2024 Jul 15 2026
Recommended Replacement
  Jun 30 2025
Warranty
  Jun 30 2026
 
Calibration Files

Date Version Author Type Document Access
 
 
User Guides & Documents

Date Version Author Type Document Access
Jul 28 2024   1        sensor_image   apollo_asp3_image
Jun 01 2024   2     Apollo Scientific/LICOR   user_manual   apollo_asp3_manual_v202406
Jul 29 2024   1     Anna Hughes   instruction_sheet   apollo_skq_info
 
 
Ownership

Quantity Value
Owner RDESC
Responsible Party RDESC
Inventory ID
Purchase Date Mar 05 2020
Acquire Date
Acquire Condition excellent
End/Lost Ownership Date
 
Vendor Support

Support Type Details
Company Apollo Scitech
Website https://apolloscitech.com/
Phone +1 302 861 6557
Email admin@apolloscitech.com
Shipping Apollo SciTech, LLC 18 Shea Way, Suite 108-109 Newark, DE 19713, USA
 
Copyright Notice: All sensor-specific images and documentation on this page are copyright of the vendor.
 
 
OSU logo NSF logo RCRV logo
RCRV Datapresence and Engineering Support Center
Oregon State University
Corvallis, OR 97331, USA
coriolix_support@oregonstate.edu