pCO2_Apollo

Summary



TypepCO2
VendorApollo Scitech
ModelApollo SciTech AS-P3 combined pCO2 analyser and underway system
S/N2101-OSU
ID Prefixpcotwo
CORIOLIX IDpcotwo002101
ClassFlowthrough
LocationNot Applicable
Conditiongood
ConfigurationGas regulator with stable delivery pressure of 15 psi (1 atm), high-quality 2-stage regulators with full delivery pressure range of 30 to 50 psi, type CGA-590 for air-balanced tanks, 3/4" PVC pipe or
Native Sample Rate1.0 Hz
UDP Port(s)53155 None
EnabledFalse
 
 
 

General Description



The Apollo ASP3 provides sea surface and atmospheric pCO2. An integrated SBE-45 thermosalinograph supports temperature and salinity correction, while the addition of 1-5 calibration gases ensures compensation with reference to known standards. Surface seawater travels through a showerhead equilibrator with a response time of 2 minutes. The equilibrated air is then dried and analyzed with an infrared or lased-based CO2 gas analyzer, the Li Cor LI-7815.

 
 

Data Collection Specs

Native Data Feed
Signal Type Digital
Communication Type Ethernet
Serial Details
Baud Rate
Parity
Stop Bits
Byte Size
Timeout (s) None
Polled Start Commands
Polled Serial Commands
Ethernet Details
MAC Address 50:81:40:FC:DF:F3
IP Address 10.3.0.45
Protocol udp
Source File Details
Path
Filename
Native Data Format
Native Data Description Data comes derived from the sensor, measurements are provided in calibrated and corrected format from the sensor. Data is broadcast over UDP and output in a JSON format.
Native Data Type text
Start of Message Characters
End of Message Characters
Sample Data Message [#v2.0[\#2024/07/28 16:43:28\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#Manual\#,\#Air\#,\#NaN\#,\#NaN\#,\#495.704\#,\#11.0068\#,\#39.9202\#,\#54.9995\#,\#0\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#18.3755\#,\#0.10631\#,\#0.6092\#,\#102.00\#,\#1006.73\#,\#16.66\#,\#0.01\#,\#6.66\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#OFF | OFF\#,\#\#,\#180\#,\#100\#,\#Continuous\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#,\#\#]#]
Message Parser Format ['^\[\Wv\d+\.\d+\[\W\W(?P<instrument_datetime>\d\d\d\d/\d\d/\d\d \d\d:\d\d:\d\d)\W\W,\W\W(?P<gps_datetime>[^,]*)\W\W,\W\W(?P<latitude>[^,]*)\W\W,\W\W(?P<longitude>[^,]*)\W\W,\W\W(?P<garmin_status>[^,]*)\W\W,\W\W(?P<garmin_datetime>[^,]*)\W\W,\W\W(?P<garmin_latitude>[^,]*)\W\W,\W\W(?P<garmin_longitude>[^,]*)\W\W,\W\W(?P<ship_gps_format>[^,]*)\W\W,\W\W(?P<ship_time>[^,]*)\W\W,\W\W(?P<ship_latitude>[^,]*)\W\W,\W\W(?P<ship_longitude>[^,]*)\W\W,\W\W(?P<mode>\w+)\W\W,\W\W(?P<source>[\w\s\-\.]+)\W\W,\W\W(?P<stddev>[Na\d\.]+)\W\W,\W\W(?P<comp_CO2>[\-\d\.\w]*)\W\W,\W\W(?P<CO2>\-?\d+\.\d+)\W\W,\W\W(?P<H2O>\-?\d+\.\d+)\W\W,\W\W(?P<cavity_pressure>\-?\d+\.\d+)\W\W,\W\W(?P<cavity_temp>\-?\d+\.\d+)\W\W,\W\W(?P<diagnostic>\d+)\W\W,(?P<li_7810>(\W\W[^,]*\W\W,){6})(?P<li_7000>(\W\W[^,]*\W\W,){7})(?P<li_850>(\W\W[^,]*\W\W,){6})(?P<picarro>(\W\W[^,]*\W\W,){6})\W\W(?P<water_temp>(\-?\d+\.\d+)?)\W\W,\W\W(?P<conductivity_Sm>(\-?\d+\.\d+)?)\W\W,\W\W(?P<salinity_psu>(\-?\d+\.\d+)?)\W\W,\W\W(?P<gas_flow_rate>\-?\d+\.\d+)\W\W,\W\W(?P<equilibrator_pressure>(\-?\d+\.\d+)?)\W\W,\W\W(?P<equilibrator_temp>(\-?\d+\.\d+)?)\W\W,\W\W(?P<water_flow_rate>(\-?\d+\.\d+)?)\W\W,\W\W(?P<cooling_pad_temp>(\-?\d+\.\d+)?)\W\W,(?P<fluorescence>(\W\W[^,]*\W\W,){3})(?P<oxygen>(\W\W[^,]*\W\W,){5})(?P<durafet>(\W\W[^,]*\W\W,){2})\W\W(?P<operator>(\w*)?)\W\W,\W\W(?P<note>[^,]*)\W\W,\W\W(?P<overflow_alarm>(\w*))\s?\|?\s?(?P<shutoff_valve>(\w*))\W\W,\W\W(?P<number_measurements>\d*)\s?\|?\s?(?P<sd_measurements>[\d\.]*)\W\W,\W\W(?P<measurement_interval>\d*)\s?\|?\s?(?P<purge_interval>\d*)\W\W,\W\W(?P<measurement_flow_rate>\-?\d*)\s?\|?\s?(?P<purge_flow_rate>\-?\d*)\W\W,\W\W(?P<test_type>\w+)\W\W,(?P<weather_station>(\W\W[^,]*\W\W,){9})(?P<li_7820>(\W\W[^,]*\W\W,){4}\W\W[^,]*\W\W)\]\W\]$']
Data Processing
Data Processing Script pCO2
Data Rates
Native Sample Rate 1.0 Hz
Shipboard Network Packet Rate 1.0 Hz
Ship to Shore Rate 1.0 Hz
Data Storage & Access
Raw Data Ethernet Distribution
IP Address 10.3.0.255
Port 53155
Packet Size None
Transformed Data Ethernet Distribution
IP Address
Port None
Archive to Database True
Transmit Real-time Data to Shore True
Time Source
Source local_time_server
 

Parameters


Quantity air_pco2 (uatm) cooling_pad_temperature (degrees_C) equilibrator_pco2 (utam) equilibrator_pressure (mbar) equilibrator_temperature (degrees_C) gas_flow_rate (ml/minute) gps_datetime ( ) gps_latitude (degrees) gps_longitude (degrees) instrument_mode ( ) instrument_timestamp ( ) li7815_cavity_pressure (kPa) li7815_cavity_temperature (degrees_C) li7815_diagnostic ( ) li7815_h2o (1/ml) li7815_xco2 (ppm) li7815_xco2_stdev (ppm) measurement_flow_rate (ml/minute) measurement_interval (s) measurement_stdev (ppm) number_of_measurements ( ) operator ( ) overflow_alarm ( ) purge_flow_rate (ml/minute) purge_interval (s) sample_source ( ) sea_water_conductivity (S/m) sea_water_pco2 (uatm) sea_water_practical_salinity ( ) sea_water_temperature (degrees_C) shutoff_valve_alarm ( ) test_type ( ) water_flow_rate (l/minute) water_vapor_pressure (atm) xco2_corr (ppm)
Plot Color
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Parameter Full Name Partial Pressure of Carbon Dioxide in Air Cooling Pad Temperature Partial Pressure of CO2 in the equilibrator Equilibrator Pressure Equilibrator Temperature Gas Flow Rate GPS Datetime From An Attached GPS Unit GPS Latitude From An Attached GPS Unit GPS Longitude From An Attached GPS Unit Instrument Mode Instrument Timestamp LI-7815 Cavity Pressure LI-7815 Cavity Temperature LI-7815 Diagnostic LI-7815 H2O LI-7815 xCO2 LI-7815 xCO2 Standard Deviation Measurement Flow Rate Measurement Interval Measurement Standard Deviation Number of Measurements Operator Identifier Overflow Alarm Purge Flow Rate Purge Interval Sample Source Sea Water Electrical Conductivity pCO2 Corrected Sea Water Practical Salinity Sea Water Temperature Shutoff Valve Alarm Test Type Water Flow Rate Water Vapor Pressure xCO2 Corrected
Parameter Short Name air_pco2 cooling_pad_temperature equilibrator_pco2 equilibrator_pressure equilibrator_temperature gas_flow_rate gps_datetime gps_latitude gps_longitude instrument_mode instrument_timestamp li7815_cavity_pressure li7815_cavity_temperature li7815_diagnostic li7815_h2o li7815_xco2 li7815_xco2_stdev measurement_flow_rate measurement_interval measurement_stdev number_of_measurements operator overflow_alarm purge_flow_rate purge_interval sample_source sea_water_conductivity sea_water_pco2 sea_water_practical_salinity sea_water_temperature shutoff_valve_alarm test_type water_flow_rate water_vapor_pressure xco2_corr
Parameter Standard Name ACO2IG01 XXXXXX PCO2EG01 XXXXXX XXXXXX XXXXXX XXXXXX XXXXXX XXXXXX XXXXXX XXXXXX XXXXXX XXXXXXXX XXXXXX XXXXXX XXXXXX XXXXXX XXXXXX XXXXXX XXXXXXXX XXXXXXXX XXXXXXXX XXXXXX XXXXXX XXXXXX XXXXXX CNDCSG02 XXXXXX SSALSG01 TEMPSU01 XXXXXX XXXXXXXX XXXXXX XXXXXX XXXXXX
SAMOS Data Category
Description The corrected partial pressure of carbon dioxide in air at the temperature of equilibrium, derived from the mole fraction of CO2 in air. The cooling pad temperature, used for diagnostic purposes. The corrected partial pressure of CO2 in seawater at the temperature of the equilibrator. The pressure of the equilibrator during measurement, used for diagnostic purposes. The temperature of the water inside the equilibrator, used for diagnostic purposes. Flow rate of gas through the system, used for diagnostic purposes. The datetime associated with a GPS connected to the Apollo ASP3. For deployment on research vessels, this value can typically be ignored and may be null because GPS data are sourced from other equipment on the vessel. GPS latitude is the latitude provided from a secondary sensor that is connected to the Apollo. Aboard research vessels, the ship's gps may or may not be piped into the Apollo. If gps_latitude data exist in the Apollo output, then it is representative of the ship position. GPS longitude is the longitude provided from a secondary sensor that is connected to the Apollo. Aboard research vessels, the ship's gps may or may not be piped into the Apollo. If gps_longitude data exist in the Apollo output, then it is representative of the ship position. Current mode of operation. Manual indicates that the sensor is being manipulated by a user. Auto indicates the sensors is performing its sampling routine. Timestamp provided by the sensor with respect to the time found by the driving computer. This is used for diagnostic purposes. The preferred timestamp should be datetime_corrected provided by the network. The cavity pressure of the LI-7815, used for diagnostic purposes. The cavity temperature of the LI-7815, typical optical cavity temperature ranges from 52 to 58 degrees Celsius. If outside of this range the instrument may not be able to regulate the cavity temperature, used for diagnostic purposes. Diagnostic code for the LI-7815. 0 = Normal Operation, 1 = Potential Noisy Measurements - Freq Adj, 2 = Potential Noisy Measurements - Laser Temp, 4 = Incomplete Scan, 8 = Potential Noisy Measurements - Startup Mode Finished, 16 = Potential Noisy Measurements - Startup Mode Init, 32 = Spectral fit RMS too high, 64 = Unregulated Pressure or Temp, 128 = Inlet Clogged, 256 = Not Ready. Invalid Measurements Measurement of water vapor. Raw measurement of the mole fraction of CO2 in dry air (xCO2), this measurement may represent air, water, or a standard calibration gas as the source. Under the factory operating mode, the Apollo typically uses the last 10 values in a sampling run to provide a raw CO2 concentration. This value represents the standard deviation of those values and can be used for diagnostic purposes. The measurement flow rate in air, in ml/min, for diagnostic purposes. The interval for measurements of air reported in seconds. The standard deviation of the measurements for each source collected. During normal operations a set of X readings are averaged and a standard deviation is provided. In the event readings are not within a standard deviation of 0.1 ppm this number may change. Used for diagnostic purposes. The number of measurements for each source collected. During normal operations this is a set of X readings that are averaged and a standard deviation is provided. In the event readings are not within a standard deviation of 0.1 ppm this number may change. Used for diagnostic purposes. The operator name or initials, used for diagnostic purposes. Indicator if an overflow alarm is triggered, used for diagnostic purposes. The flow rate of the purge cycle between different sets of measurements. The amount of time purging occurs between samples and standards at the given purge flow rate. Current analysis stream, consists of air, seawater, or standard gas. In conjunction with the Apollo pCO2 system, this thermosalinograph measures flowthrough sea surface conductivity ranging from 0-7 S/m. Conductivity output from this TSG is used to derive salinity and further correct pCO2 data. The partial pressure of carbon dioxide in seawater at the in-situ temperature using the equation of Takahashi et al. (2002) that utilizes the sea surface temperature measured at the ship's intake and the temperature measured at equilibration. In conjunction with the Apollo pCO2 system, data is derived to produce flowthrough sea surface salinity in PSU. Salinity derived from this TSG is used to correct pCO2 data. In conjunction with the Apollo pCO2 system, this thermosalinograph measures flowthrough sea surface temperature ranging from -5 to 35 degC. The difference between temperature measured at the Main Lab TSG and that of the temperature measured by the SBE-38 at the intake are used to correct for any temperature change due to residence time and further used to correct pCO2 data. Indicator if a shutoff valve alarm is triggered, used for diagnostic purposes. The type of test during the measurement, during normal operations the output will read continuous. Used for diagnostic purposes. The flow rate of the water through the sensor, used for diagnostic purposes. The water vapor pressure at equilibration calculated using the salinity and temperature values from the intake temperature and salinity. The corrected xCO2 concentration derived from the raw equilibrator data output and measured and corrected CO2 concentration from standard gases. This applies to both seawater and air measurements.
Processing Status post processed with ancillary data raw post processed with ancillary data raw raw raw externally sourced externally sourced externally sourced raw raw raw raw raw raw internally derived internally derived raw raw raw raw raw raw raw raw raw raw post processed with ancillary data internally derived raw raw raw raw post processed with ancillary data internally derived
Processing Symbol pco2_atmospheric cooling_pad_temp pco2_equilibrator equilibrator_pressure equilibrator_temp gas_flow_rate gps_datetime latitude longitude mode instrument_datetime cavity_pressure cavity_temp diagnostic H2O CO2 stddev measurement_flow_rate measurement_interval sd_measurements number_measurements operator overflow_alarm purge_flow_rate purge_interval source conductivity_Sm pco2_corrected salinity_psu water_temp shutoff_valve test_type water_flow_rate water_vapor comp_CO2
Diagnostic False True False True True True True True True True True True True True False False True True True True True True True True True True False False False False True True True False False
IOOS Category CO2 Other CO2 Other Temperature Other Other Location Location Other Other Other Other Other Other CO2 Other Other Other Other Other Other Other Other Other Other Other CO2 Salinity Temperature Other Unknown Other Other Other
Units uatm degrees_C utam mbar degrees_C ml/minute degrees degrees kPa degrees_C 1/ml ppm ppm ml/minute s ppm ml/minute s S/m uatm degrees_C l/minute atm ppm
Data Type float float float float float float double String String String double float float byte float float float short short float byte String String short short String float float float float String String float float float
Gross Minimum Value 0.0 uatm 0.0 degrees_C 0.0 utam None mbar 0.0 degrees_C 60.0 ml/minute None -90.0 degrees -180.0 degrees None None 70.0 kPa 52.0 degrees_C 0.0 0.0 1/ml 0.0 ppm 0.0 ppm 0.0 ml/minute 1.0 s 0.0 ppm 1.0 None None None ml/minute None s None 0.0 S/m None uatm 2.0 -5.0 degrees_C None None 1.7 l/minute 100.0 atm 0.0 ppm
Gross Maximum Value 1800.0 uatm 50.0 degrees_C 1800.0 utam None mbar 50.0 degrees_C 400.0 ml/minute None 90.0 degrees 180.0 degrees None None 110.0 kPa 58.0 degrees_C 256.0 14000.0 1/ml 10000.0 ppm 0.1 ppm 400.0 ml/minute 300.0 s 0.25 ppm 100.0 None None None ml/minute None s None 7.0 S/m None uatm 42.0 35.0 degrees_C None None 3.4 l/minute 60000.0 atm 1800.0 ppm
Recommended Minimum Value 100.0 uatm None degrees_C None utam None mbar None degrees_C 75.0 ml/minute None None degrees None degrees None None None kPa None degrees_C None None 1/ml None ppm None ppm None ml/minute None s 0.0 ppm None None None None ml/minute None s None 2.6 S/m None uatm 5.0 None degrees_C None None None l/minute None atm 100.0 ppm
Recommended Maximum Value 504.0 uatm None degrees_C None utam None mbar None degrees_C 350.0 ml/minute None None degrees None degrees None None None kPa None degrees_C None None 1/ml None ppm None ppm None ml/minute None s 0.1 ppm None None None None ml/minute None s None 6.0 S/m None uatm 38.0 None degrees_C None None None l/minute None atm 504.0 ppm
Global Minimum Value None uatm None degrees_C None utam None mbar None degrees_C None ml/minute None None degrees None degrees None None None kPa None degrees_C None None 1/ml None ppm None ppm None ml/minute None s None ppm None None None None ml/minute None s None None S/m None uatm 2.0 None degrees_C None None None l/minute None atm None ppm
Global Maximum Value None uatm None degrees_C None utam None mbar None degrees_C None ml/minute None None degrees None degrees None None None kPa None degrees_C None None 1/ml None ppm None ppm None ml/minute None s None ppm None None None None ml/minute None s None None S/m None uatm 42.0 None degrees_C None None None l/minute None atm None ppm
Local Minimum Value None uatm None degrees_C None utam None mbar None degrees_C None ml/minute None None degrees None degrees None None None kPa None degrees_C None None 1/ml None ppm None ppm None ml/minute None s None ppm None None None None ml/minute None s None None S/m None uatm None None degrees_C None None None l/minute None atm None ppm
Local Maximum Value None uatm None degrees_C None utam None mbar None degrees_C None ml/minute None None degrees None degrees None None None kPa None degrees_C None None 1/ml None ppm None ppm None ml/minute None s None ppm None None None None ml/minute None s None None S/m None uatm None None degrees_C None None None l/minute None atm None ppm
Lower Detection Limit None uatm None degrees_C None utam None mbar None degrees_C None ml/minute None None degrees None degrees None None None kPa None degrees_C None None 1/ml None ppm None ppm None ml/minute None s None ppm None None None None ml/minute None s None 0.0 S/m None uatm None None degrees_C None None None l/minute None atm None ppm
Saturated Value None uatm None degrees_C None utam None mbar None degrees_C None ml/minute None None degrees None degrees None None None kPa None degrees_C None None 1/ml None ppm None ppm None ml/minute None s None ppm None None None None ml/minute None s None 7.0 S/m None uatm None None degrees_C None None None l/minute None atm None ppm
Bad Data Value None uatm None degrees_C None utam None mbar None degrees_C None ml/minute None None degrees None degrees None None None kPa None degrees_C None None 1/ml None ppm None ppm None ml/minute None s None ppm None None None None ml/minute None s None 7.0 S/m None uatm None None degrees_C None None None l/minute None atm None ppm
Resolution 0.1 uatm None degrees_C 0.1 utam None mbar None degrees_C 1.0 ml/minute None None degrees None degrees None None None kPa None degrees_C None None 1/ml None ppm None ppm None ml/minute None s None ppm None None None None ml/minute None s None 0.00001 S/m None uatm 0.0 None degrees_C None None None l/minute None atm 0.1 ppm
Accuracy +/- 0.1 uatm +/- None degrees_C +/- 0.1 utam +/- None mbar +/- None degrees_C +/- 1.0 ml/minute +/- None +/- None degrees +/- None degrees +/- None +/- None +/- None kPa +/- None degrees_C +/- None +/- None 1/ml +/- None ppm +/- None ppm +/- None ml/minute +/- None s +/- None ppm +/- None +/- None +/- None +/- None ml/minute +/- None s +/- None +/- 0.0003 S/m +/- None uatm +/- None +/- None degrees_C +/- None +/- None +/- None l/minute +/- None atm +/- 0.1 ppm
Precision 0.1 uatm None degrees_C 0.1 utam None mbar None degrees_C 1.0 ml/minute None None degrees None degrees None None None kPa None degrees_C None None 1/ml 0.1 ppm None ppm None ml/minute None s None ppm None None None None ml/minute None s None 0.0001 S/m None uatm None None degrees_C None None None l/minute None atm 0.1 ppm
Binning Type spot linear linear
Online Display Format 5.1f 1.2f 5.1f 4.1f 2.1f 3.1f 19.0f 3.2f 3.2f 4.0f 19.0f 2.2f 3.1f 3.0f 1.2f 5.0f 1.3f 3.0f 2.0f 3.2f 3.0f 5.0f 0.0f 3.0f 2.0f 4.0f 1.2f 5.1f 2.1f 2.2f 0.0f 10.0f 1.1f 5.1f 5.2f
Logging Modes
 

Physical Sensor Specs

Operating Limits
Input Power 115.0 - 120.0 V AC
Ideal Power 115.0 V AC
Operating Current None - None mA @ None V AC
Analog Output None - None
Operating Flow Rate 63.0 - 83.0 ml s-1
Ideal Flow Rate 67.0 ml s-1
Operating Depth 0 - 0 m
Operating Temperature -25 - 45 degree_C
Lamp Life None days
Response Time 120.0 seconds
Additional Time Offset 1.0 seconds
Physical Status
Current Location no longer in possession
Current Status unavailable
Physical Condition good
Physical Configuration Gas regulator with stable delivery pressure of 15 psi (1 atm), high-quality 2-stage regulators with full delivery pressure range of 30 to 50 psi, type CGA-590 for air-balanced tanks, 3/4" PVC pipe or
Software Version AS-pco2-RV3.0
Software Configuration
Data Acquisition Device ID
Data Acquisition Device Serial Port
Data Acquisition Device Analog/Digital Port(s)
Data Acquisition Device Modbus Unit None
Sensor Use Level
Enabled False
Vessel Installation Location
Vessel sikuliaq
Vessel Location Not Applicable
Location Coordinates (meters)
Sensor Orientation not applicable
Height Above Waterline (meters) None
Zero Line Reference (degrees from bow) None
Receives Filtered Water False
 

Maintenance & Support

Sensor Log

    Date (UTC)     Submitter     Event Type     Details        
Nov 06 2024 16:08:11     Greto, Carmen     sensor specs update     use_level changed from [secondary] to []    
Nov 06 2024 16:08:11     Greto, Carmen     sensor specs update     location_text changed from [Wet Lab] to [Not Applicable]    
Nov 06 2024 16:08:11     Greto, Carmen     sensor specs update     enabled changed from [True] to [False]    
Nov 06 2024 16:08:11     Greto, Carmen     sensor specs update     current_status changed from [in use] to [unavailable]    
Nov 06 2024 16:08:11     Greto, Carmen     sensor specs update     current_location changed from [installed] to [no longer in possession]    
Aug 12 2024 19:00:00     Black, Ian     diagnosis     The Apollo data are now stable and integrated with the calibration standards. Data collected prior to this timestamp was used to diagnose sensor issues and should be considered bad/experimental.    
Aug 12 2024 18:45:59     Black, Ian     sensor specs update     current_status changed from [testing in progress] to [in use]    
Aug 09 2024 19:00:00     Black, Ian     issue     The LI-7815 is reporting negative values, which should be physically impossible. Tests are being performed to diagnose this issue.    
Aug 09 2024 18:00:00     Black, Ian     test     The 418.9ppm was applied to the Apollo after testing for gas line leaks.    
Aug 04 2024 21:23:37     Black, Ian     sensor specs update     maintenance_C_freq_days changed from [None] to [0]    
Aug 04 2024 21:23:37     Black, Ian     sensor specs update     maintenance_C_text changed from [test001] to [Freshwater Flush]    
Aug 04 2024 21:23:37     Black, Ian     sensor specs update     maintenance_B_freq_days changed from [None] to [3]    
Aug 04 2024 21:23:37     Black, Ian     sensor specs update     maintenance_B_text changed from [] to [Secondary Filter Check]    
Aug 04 2024 21:23:37     Black, Ian     sensor specs update     maintenance_A_text changed from [Filter Check] to [Primary Filter Check]    
Aug 04 2024 21:23:37     Black, Ian     sensor specs update     condition changed from [excellent] to [good]    
Aug 04 2024 21:23:37     Black, Ian     sensor specs update     depth_max_meters changed from [None] to [0]    
Aug 04 2024 21:23:37     Black, Ian     sensor specs update     depth_min_meters changed from [None] to [0]    
Aug 04 2024 21:23:37     Black, Ian     sensor specs update     flow_rate_ideal_mls changed from [63.0] to [67]    
Aug 04 2024 21:23:37     Black, Ian     sensor specs update     flow_rate_min_mls changed from [67.0] to [63]    
Aug 04 2024 21:23:37     Black, Ian     sensor specs update     description changed from [Flowthrough measurem ... the Li Cor LI-7815.] to [The Apollo ASP3 prov ... the Li Cor LI-7815.]    
Aug 02 2024 17:00:00     Black, Ian     test     The Apollo ASP3 was turned on with seawater-air cycles only until the LDEO pCO2 system has the new calibration gas installed and is tested with satisfaction.    
Aug 02 2024 17:00:00     Black, Ian     change of use level     Data collected by the Apollo prior to this timestamp and until another change in use level should be considered experimental and likely does not reflect natural changes.    
Jul 31 2024 18:01:00     Black, Ian     software update     Users may recalculate bad air_pco2 from CORIOLIX output by using air xCO2, barometric pressure from a shipside source, and water vapor pressure calculated using the intake SBE 38 and SBE45.    
Jul 31 2024 18:00:00     Black, Ian     software update     An issue with the air_pco2 value calculation was identified. The incorrect units were used for pressure. air_pco2 data prior to this timestamp are considered bad. A patch was pushed to fix this issue.    
Jul 30 2024 20:01:00     Black, Ian     issue     The Apollo sampling routine has been disabled until we can determine the optimal standard sampling pattern and verify there are no more standard leaks. Priority is to keep the LDEO running.    
Jul 30 2024 20:00:00     Black, Ian     issue     The 385ppm standard drained overnight. There is concern of a leak and that the Apollo may be drawing more standard than anticipated. The standards to the Apollo have been closed off.    
Jul 29 2024 06:02:10     Black, Ian     sensor specs update     warranty_end_date changed from [None] to [2026-06-30 00:00:00+00:00]    
Jul 29 2024 06:02:10     Black, Ian     sensor specs update     replacement_date changed from [None] to [2025-06-30 00:00:00+00:00]    
Jul 29 2024 06:02:10     Black, Ian     sensor specs update     last_cal_date changed from [None] to [2024-07-15 00:00:00+00:00]    
Jul 29 2024 06:02:10     Black, Ian     sensor specs update     cal_recommended_freq_months changed from [None] to [24]    
Jul 29 2024 06:02:10     Black, Ian     sensor specs update     maintenance_A_freq_days changed from [None] to [1]    
Jul 29 2024 06:02:10     Black, Ian     sensor specs update     maintenance_A_text changed from [] to [Filter Check]    
Jul 29 2024 06:02:10     Black, Ian     sensor specs update     time_source changed from [] to [local_time_server]    
Jul 28 2024 18:55:34     Nahorniak, Jasmine     renamed sensor     Changed sensor ID from pcotwo002202 to pcotwo002101.    
Jul 28 2024 18:51:45     Black, Ian     sensor specs update     sensor_orientation changed from [] to [not applicable]    
Jul 28 2024 18:51:45     Black, Ian     sensor specs update     software_version changed from [AS-pco2-RV2.0] to [AS-pco2-RV3.0]    
Jul 28 2024 18:51:45     Black, Ian     sensor specs update     current_status changed from [calibration in progress] to [testing in progress]    
Jul 28 2024 18:51:45     Black, Ian     sensor specs update     power_ideal_volts changed from [None] to [115.0]    
Jul 27 2024 21:49:31     Race, Julian     sensor specs update     sensor_ip changed from [10.3.0.155] to [10.3.0.45]    
Jul 27 2024 21:44:28     Race, Julian     sensor specs update     enabled changed from [False] to [True]    
Jul 27 2024 21:44:28     Race, Julian     sensor specs update     serial_number changed from [2202-OSU] to [2101-OSU]    
Jul 27 2024 14:40:04     Greto, Carmen     sensor specs update     location_text changed from [Main Lab] to [Wet Lab]    
Jul 27 2024 14:40:04     Greto, Carmen     sensor specs update     current_location changed from [RDESC] to [installed]    
Jul 27 2024 14:38:49     Greto, Carmen     sensor specs update     sensor_name changed from [pCO2] to [pCO2_Apollo]    
Jul 26 2024 12:00:00     Black, Ian     installation     Sensor was installed in the SKQ Wet Lab.    
Jul 02 2024 22:38:36     Nahorniak, Jasmine     sensor specs update     retransmit_port changed from [40325] to [None]    
Jul 02 2024 22:38:36     Nahorniak, Jasmine     sensor specs update     retransmit_ip changed from [172.16.40.255] to []    
Jul 02 2024 22:38:36     Nahorniak, Jasmine     sensor specs update     transmit_port changed from [30325] to [53155]    
Jul 02 2024 22:38:36     Nahorniak, Jasmine     sensor specs update     transmit_ip changed from [172.16.30.29] to [10.3.0.255]    
Jul 02 2024 22:38:36     Nahorniak, Jasmine     sensor specs update     sensor_ip changed from [170.16.30.95] to [10.3.0.155]    
Jul 02 2024 18:41:08     Nahorniak, Jasmine     sensor specs update     vendor changed from [Not Applicable] to [Apollo Scitech]    
Jul 02 2024 17:26:28     Nahorniak, Jasmine     sensor specs update     use_level changed from [primary] to [secondary]    
Jul 02 2024 17:26:28     Nahorniak, Jasmine     sensor specs update     vessel changed from [Taani] to [Sikuliaq]    
Jul 02 2024 17:26:28     Nahorniak, Jasmine     sensor specs update     vendor changed from [Apollo Scitech] to [Not Applicable]    
 
Calibration & Maintenance

Frequency Last Completed Next Due
Maintenance A: Primary Filter Check
  1 days
Maintenance B: Secondary Filter Check
  3 days
Maintenance C: test001
 
Calibration
  24 months Jul 15 2024 Jul 15 2026
Recommended Replacement
  Jun 30 2025
Warranty
  Jun 30 2026
 
Calibration Files

Date Version Author Type Document Access
 
 
User Guides & Documents

Date Version Author Type Document Access
Jul 28 2024   1        sensor_image   apollo_asp3_image
Jun 01 2024   2     Apollo Scientific/LICOR   user_manual   apollo_asp3_manual_v202406
Jul 29 2024   1     Anna Hughes   instruction_sheet   apollo_skq_info
 
 
Ownership

Quantity Value
Owner RDESC
Responsible Party RDESC
Purchase Date Mar 05 2020
Acquire Date
Acquire Condition excellent
End/Lost Ownership Date
 
Vendor Support

Support Type Details
Company Apollo Scitech
Website https://apolloscitech.com/
Phone +1 302 861 6557
Email admin@apolloscitech.com
Shipping Apollo SciTech, LLC 18 Shea Way, Suite 108-109 Newark, DE 19713, USA
 
Copyright Notice: All sensor-specific images and documentation on this page are copyright of the vendor.
 
 
OSU logo NSF logo RCRV logo
RCRV Datapresence and Engineering Support Center
Oregon State University
Corvallis, OR 97331, USA