Fluorometer ECO-FLNTURTD_5094

Summary



TypeFluorometer
VendorSea-Bird Scientific (WET Labs)
ModelWET Labs {Sea-Bird WETLabs} ECO FLNTU(RT)D combined fluorometer and turbidity sensor
S/N5094
ID Prefix
CORIOLIX IDfluoro005094
ClassOverTheSide
Location
Conditiongood
ConfigurationConfigured with SBE cable 172285
Native Sample Rate8.0 Hz
UDP Port(s)None None
EnabledFalse
 


Image Not Available
 
 

General Description



ECO (Environmental Characterization Optics) fluorometer with an optical scattering measurement at 700 nm for simultaneous determination of turbidity

 
 

Data Collection Specs

Native Data Feed
Signal Type Analog
Communication Type Voltage
Serial Details
Baud Rate 19200
Parity
Stop Bits
Byte Size
Timeout (s) None
Polled Start Commands
Polled Serial Commands
Ethernet Details
MAC Address
IP Address
Protocol
Source File Details
Path
Filename
Native Data Format
Native Data Description Measurements are provided from the sensor in either analog output signal in volts or a digital output using RS-232 with 12 bit resolution.
Native Data Type
Start of Message Characters
End of Message Characters
Sample Data Message
Message Parser Format
Data Processing
Data Processing Script NoTransformation
Data Rates
Native Sample Rate 8.0 Hz
Shipboard Network Packet Rate 1.0 Hz
Ship to Shore Rate 1.0 Hz
Data Storage & Access
Raw Data Ethernet Distribution
IP Address
Port None
Packet Size None
Transformed Data Ethernet Distribution
IP Address
Port None
Archive to Database True
Transmit Real-time Data to Shore True
Time Source
Source
 

Parameters


Quantity
Plot Color
Parameter Full Name
Parameter Short Name
Parameter Standard Name
SAMOS Data Category
Description
Processing Status
Processing Symbol
Diagnostic
IOOS Category
Units
Data Type
Gross Minimum Value
Gross Maximum Value
Recommended Minimum Value
Recommended Maximum Value
Global Minimum Value
Global Maximum Value
Local Minimum Value
Local Maximum Value
Lower Detection Limit
Saturated Value
Bad Data Value
Resolution
Accuracy
Precision
Binning Type
Online Display Format
Logging Modes
 

Physical Sensor Specs

Operating Limits
Input Power 7.0 - 15.0 V DC
Ideal Power None V DC
Operating Current 0.14 - 60.0 mA @ 14.0 V DC
Analog Output 0 - 5 Volts
Operating Flow Rate None - None ml s-1
Ideal Flow Rate None ml s-1
Operating Depth 0 - 6000 m
Operating Temperature 0 - 30 degree_C
Lamp Life None days
Response Time None seconds
Additional Time Offset None seconds
Physical Status
Current Location on vessel
Current Status not in use
Physical Condition good
Physical Configuration Configured with SBE cable 172285
Software Version
Software Configuration
Data Acquisition Device ID
Data Acquisition Device Serial Port
Data Acquisition Device Analog/Digital Port(s)
Data Acquisition Device Modbus Unit None
Sensor Use Level
Enabled False
Vessel Installation Location
Vessel sikuliaq
Vessel Location
Location Coordinates (meters)
Sensor Orientation horizontal
Height Above Waterline (meters) None
Zero Line Reference (degrees from bow) None
Receives Filtered Water False
 

Maintenance & Support

Sensor Log

    Date (UTC)     Submitter     Event Type     Details        
Oct 20 2024 18:09:26     Matthias, Gabriel     sensor specs update     current_location changed from [in transit] to [on vessel]    
Oct 05 2024 21:39:45     Nahorniak, Jasmine     sensor specs update     processing_script changed from [] to [NoTransformation]    
Oct 05 2024 21:39:45     Nahorniak, Jasmine     sensor specs update     model changed from [WETLabs ECO-FLNTU(RT ... and turbidity sensor] to [WET Labs {Sea-Bird W ... and turbidity sensor]    
Sep 04 2024 18:19:46     Grischuk, Jenny     sensor specs update     last_cal_date changed from [2023-12-13 00:00:00+00:00] to [2024-07-30 00:00:00+00:00]    
Sep 04 2024 18:19:46     Grischuk, Jenny     sensor specs update     current_status changed from [calibration in progress] to [not in use]    
Sep 04 2024 18:19:46     Grischuk, Jenny     sensor specs update     current_location changed from [repair/calibration] to [in transit]    
Jun 16 2024 22:46:10     Grischuk, Jenny     sensor specs update     location_text changed from [Tech Stores] to []    
Jun 16 2024 22:46:10     Grischuk, Jenny     sensor specs update     current_status changed from [not in use] to [calibration in progress]    
Jun 16 2024 22:46:10     Grischuk, Jenny     sensor specs update     current_location changed from [on vessel] to [repair/calibration]    
Jun 16 2024 18:00:28     Grischuk, Jenny     sensor specs update     last_cal_date changed from [2023-12-13 03:37:00+00:00] to [2023-12-13 00:00:00+00:00]    
Jun 16 2024 18:00:28     Grischuk, Jenny     sensor specs update     current_status changed from [unavailable] to [not in use]    
Dec 13 2023 03:37:00     Naber, Daniel     calibration logistics     Send in for calibration, end of year 2024.    
Dec 13 2023 03:29:13     Naber, Daniel     sensor specs update     maintenance_C_text changed from [test001] to []    
Dec 13 2023 03:29:13     Naber, Daniel     sensor specs update     use_level changed from [primary] to []    
Dec 13 2023 03:29:13     Naber, Daniel     sensor specs update     location_text changed from [Baltic Room] to [Tech Stores]    
Dec 13 2023 03:29:12     Naber, Daniel     sensor specs update     enabled changed from [True] to [False]    
Dec 13 2023 03:29:12     Naber, Daniel     sensor specs update     current_status changed from [in use] to [unavailable]    
Dec 13 2023 03:29:12     Naber, Daniel     sensor specs update     current_location changed from [installed] to [on vessel]    
May 27 2023 03:23:00     Naber, Daniel     installation         
May 27 2023 03:10:44     Naber, Daniel     sensor specs update     time_source changed from [vessel_time_server] to []    
May 27 2023 03:10:44     Naber, Daniel     sensor specs update     use_level changed from [] to [primary]    
May 27 2023 03:10:44     Naber, Daniel     sensor specs update     sensor_orientation changed from [] to [horizontal]    
May 27 2023 03:10:44     Naber, Daniel     sensor specs update     location_text changed from [Tech Stores] to [Baltic Room]    
May 27 2023 03:10:44     Naber, Daniel     sensor specs update     enabled changed from [False] to [True]    
May 27 2023 03:10:44     Naber, Daniel     sensor specs update     current_status changed from [not in use] to [in use]    
May 27 2023 03:10:44     Naber, Daniel     sensor specs update     current_location changed from [on vessel] to [installed]    
Oct 21 2022 04:23:42     Kopka, Krystian     sensor specs update     location_text changed from [Not Applicable] to [Tech Stores]    
Oct 21 2022 00:04:03     Kopka, Krystian     sensor specs update     use_level changed from [spare] to []    
Oct 07 2022 07:32:57     Kopka, Krystian     sensor specs update     last_cal_date changed from [2018-06-07 00:00:00+00:00] to [2021-12-20 00:00:00+00:00]    
May 23 2022 23:43:50     Greto, Carmen     sensor specs update     sensor_name changed from [Fluoro_ECO-FLNTURTD_5094] to [Fluorometer ECO-FLNTURTD_5094]    
Jan 27 2022 22:12:45     Greto, Carmen     sensor specs update     maintenance_A_freq_days changed from [None] to [30]    
Jan 27 2022 22:12:45     Greto, Carmen     sensor specs update     maintenance_A_text changed from [] to [Kim wipe optical lens, DI rinse]    
Jan 27 2022 22:12:45     Greto, Carmen     sensor specs update     transmit_rate_hz changed from [None] to [1.0]    
Jan 27 2022 22:12:45     Greto, Carmen     sensor specs update     packet_rate_hz changed from [None] to [1.0]    
Jan 27 2022 22:12:45     Greto, Carmen     sensor specs update     time_source changed from [] to [vessel_time_server]    
Jan 27 2022 22:12:45     Greto, Carmen     sensor specs update     use_level changed from [] to [spare]    
Jan 27 2022 22:12:45     Greto, Carmen     sensor specs update     location_text changed from [] to [Not Applicable]    
Jan 27 2022 22:12:45     Greto, Carmen     sensor specs update     configuration changed from [] to [Configured with SBE cable 172285]    
Jan 27 2022 22:12:45     Greto, Carmen     sensor specs update     condition changed from [] to [good]    
Jan 27 2022 22:12:45     Greto, Carmen     sensor specs update     current_status changed from [] to [not in use]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     current_location changed from [] to [on vessel]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     acquire_condition changed from [] to [excellent]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     acquire_date changed from [None] to [2018-01-01 00:00:00+00:00]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     purchase_date changed from [None] to [2018-01-01 00:00:00+00:00]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     temperature_max_celsius changed from [None] to [30]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     temperature_min_celsius changed from [None] to [0]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     depth_max_meters changed from [None] to [6000]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     depth_min_meters changed from [None] to [0]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     analog_units changed from [] to [Volts]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     analog_max changed from [None] to [5]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     analog_min changed from [None] to [0]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     current_reference_volts changed from [None] to [14.0]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     current_max_milliamps changed from [None] to [60.0]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     current_min_milliamps changed from [None] to [0.14]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     power_current_type changed from [] to [DC]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     power_max_volts changed from [None] to [15.0]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     power_min_volts changed from [None] to [7.0]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     native_data_description changed from [] to [Measurements are pro ... h 12 bit resolution.]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     sample_rate_hz changed from [None] to [8.0]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     serial_baud_rate changed from [] to [19200]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     comm_type changed from [] to [Voltage]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     signal_type changed from [] to [Analog]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     description changed from [Fluorometer] to [ECO (Environmental C ... ination of turbidity]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     serial_number changed from [FLNTURTD-5094] to [5094]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     model changed from [ECO-FLNTURTD] to [WETLabs ECO-FLNTU(RT ... and turbidity sensor]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     vendor changed from [Sea-Bird Scientific (WET Labs)] to [Sea-Bird Scientific (WET Labs) ]    
Jan 27 2022 22:12:44     Greto, Carmen     sensor specs update     sensor_name changed from [Fluorometer - ctd] to [Fluoro_ECO-FLNTURTD_5094]    
Feb 20 2021 00:43:34     Roberts, Steve     new sensor     Initial submission of sensor metadata.    
 
Calibration & Maintenance

Frequency Last Completed Next Due
Maintenance A: Kim wipe optical lens, DI rinse
  30 days
Maintenance B:
 
Maintenance C: test001
 
Calibration
  24 months Jul 30 2024 Jul 30 2026
Recommended Replacement
 
Warranty
 
 
Calibration Files

Date Version Author Type Document Access
Jul 30 2024        Seabird   cal_file   FLNTURTD-5094_Char Sheet
Jul 30 2024        Seabird   cal_file   FLNTURTD-5094.dev
May 26 2023           cal_file   20230526_5094_field_Dark_Count.txt
Dec 20 2021           cal_file   Fluorometer ECO-FLNTURTD_5094 CAL_PDF
Jun 07 2018           cal_file   Fluorometer ECO-FLNTURTD_5094 CAL_PDF
 
 
User Guides & Documents

Date Version Author Type Document Access
Jul 30 2024           repair_sheet   FLNTURTD-5094_Repair Sheet
 
 
Ownership

Quantity Value
Owner UAF
Responsible Party UAF Marine Technicians
Purchase Date Jan 01 2018
Acquire Date Jan 01 2018
Acquire Condition excellent
End/Lost Ownership Date
 
Vendor Support

Support Type Details
Company Sea-Bird Scientific (WET Labs)
Website http://wetlabs.com
Phone 5419295650
Email service@wetlabs.com
Shipping WET Labs, 620 Applegate Street, Philomath OR 97370, USA
 
Copyright Notice: All sensor-specific images and documentation on this page are copyright of the vendor.
 
 
OSU logo NSF logo RCRV logo
RCRV Datapresence and Engineering Support Center
Oregon State University
Corvallis, OR 97331, USA