Conductivity SBE 04_4367

Summary



TypeCTD
VendorSea-Bird Scientific (Sea-Bird Electronics)
ModelSea-Bird SBE 4C conductivity sensor
S/N4367
ID Prefix
CORIOLIX IDconduc004367
ClassOverTheSide
Location
Conditiongood
ConfigurationConfigured with SBE cable171669
Native Sample Rate24.0 Hz
UDP Port(s)None None
EnabledFalse
 


Image Not Available
 
 

General Description



Conductivity Sensor

 
 

Data Collection Specs

Native Data Feed
Signal Type Analog
Communication Type Frequency
Serial Details
Baud Rate
Parity
Stop Bits
Byte Size
Timeout (s) None
Polled Start Commands
Polled Serial Commands
Ethernet Details
MAC Address
IP Address
Protocol
Source File Details
Path
Filename
Native Data Format
Native Data Description Square-wave variable frequency output signal (nominally 2.5 to 7.5 kHz, corresponding to 0 to 7 S/m)
Native Data Type text
Start of Message Characters
End of Message Characters
Sample Data Message
Message Parser Format
Data Processing
Data Processing Script NoTransformation
Data Rates
Native Sample Rate 24.0 Hz
Shipboard Network Packet Rate 1.0 Hz
Ship to Shore Rate 1.0 Hz
Data Storage & Access
Raw Data Ethernet Distribution
IP Address
Port None
Packet Size None
Transformed Data Ethernet Distribution
IP Address
Port None
Archive to Database True
Transmit Real-time Data to Shore True
Time Source
Source
 

Parameters


Quantity
Plot Color
Parameter Full Name
Parameter Short Name
Parameter Standard Name
SAMOS Data Category
Description
Processing Status
Processing Symbol
Diagnostic
IOOS Category
Units
Data Type
Gross Minimum Value
Gross Maximum Value
Recommended Minimum Value
Recommended Maximum Value
Global Minimum Value
Global Maximum Value
Local Minimum Value
Local Maximum Value
Lower Detection Limit
Saturated Value
Bad Data Value
Resolution
Accuracy
Precision
Binning Type
Online Display Format
Logging Modes
 

Physical Sensor Specs

Operating Limits
Input Power 6.0 - 24.0 V DC
Ideal Power None V DC
Operating Current 12.0 - 12.0 mA @ 14.0 V DC
Analog Output 2500 - 7500 Hertz
Operating Flow Rate None - None ml s-1
Ideal Flow Rate None ml s-1
Operating Depth 0 - 6800 m
Operating Temperature None - None degree_C
Lamp Life None days
Response Time 0.06 seconds
Additional Time Offset None seconds
Physical Status
Current Location on vessel
Current Status not in use
Physical Condition good
Physical Configuration Configured with SBE cable171669
Software Version
Software Configuration
Data Acquisition Device ID
Data Acquisition Device Serial Port
Data Acquisition Device Analog/Digital Port(s)
Data Acquisition Device Modbus Unit None
Sensor Use Level
Enabled False
Vessel Installation Location
Vessel sikuliaq
Vessel Location
Location Coordinates (meters)
Sensor Orientation horizontal
Height Above Waterline (meters) None
Zero Line Reference (degrees from bow) None
Receives Filtered Water False
 

Maintenance & Support

Sensor Log

    Date (UTC)     Submitter     Event Type     Details        
Oct 20 2024 18:06:15     Matthias, Gabriel     sensor specs update     current_location changed from [in transit] to [on vessel]    
Oct 20 2024 18:06:15     Matthias, Gabriel     sensor specs update     processing_script changed from [] to [NoTransformation]    
Sep 03 2024 20:31:21     Grischuk, Jenny     sensor specs update     last_cal_date changed from [2023-12-05 00:00:00+00:00] to [2024-07-23 00:00:00+00:00]    
Sep 03 2024 20:31:21     Grischuk, Jenny     sensor specs update     current_status changed from [calibration in progress] to [not in use]    
Sep 03 2024 20:31:21     Grischuk, Jenny     sensor specs update     current_location changed from [repair/calibration] to [in transit]    
Jun 16 2024 20:40:14     Grischuk, Jenny     sensor specs update     location_text changed from [Tech Stores] to []    
Jun 16 2024 20:40:14     Grischuk, Jenny     sensor specs update     current_status changed from [not in use] to [calibration in progress]    
Jun 16 2024 20:40:14     Grischuk, Jenny     sensor specs update     current_location changed from [on vessel] to [repair/calibration]    
Jun 16 2024 19:09:07     Grischuk, Jenny     sensor specs update     last_cal_date changed from [2023-12-05 21:55:00+00:00] to [2023-12-05 00:00:00+00:00]    
Jun 16 2024 19:09:07     Grischuk, Jenny     sensor specs update     current_status changed from [unavailable] to [not in use]    
Dec 05 2023 21:55:00     Naber, Daniel     calibration logistics     Send in for calibration, mid-year 2024.    
Dec 05 2023 21:47:12     Naber, Daniel     sensor specs update     maintenance_C_text changed from [test001] to []    
Dec 05 2023 21:47:12     Naber, Daniel     sensor specs update     use_level changed from [secondary] to []    
Dec 05 2023 21:47:12     Naber, Daniel     sensor specs update     location_text changed from [Baltic Room] to [Tech Stores]    
Dec 05 2023 21:47:12     Naber, Daniel     sensor specs update     enabled changed from [True] to [False]    
Dec 05 2023 21:47:12     Naber, Daniel     sensor specs update     current_status changed from [in use] to [unavailable]    
Dec 05 2023 21:47:12     Naber, Daniel     sensor specs update     current_location changed from [installed] to [on vessel]    
May 27 2023 02:54:00     Naber, Daniel     installation         
May 27 2023 02:53:27     Naber, Daniel     sensor specs update     time_source changed from [vessel_time_server] to []    
May 27 2023 02:53:27     Naber, Daniel     sensor specs update     use_level changed from [] to [secondary]    
May 27 2023 02:53:27     Naber, Daniel     sensor specs update     location_text changed from [Tech Stores] to [Baltic Room]    
May 27 2023 02:53:27     Naber, Daniel     sensor specs update     enabled changed from [False] to [True]    
May 27 2023 02:53:27     Naber, Daniel     sensor specs update     current_status changed from [not in use] to [in use]    
May 27 2023 02:53:27     Naber, Daniel     sensor specs update     current_location changed from [on vessel] to [installed]    
Oct 21 2022 02:34:50     Kopka, Krystian     sensor specs update     location_text changed from [Not Applicable] to [Tech Stores]    
Oct 20 2022 09:07:38     Kopka, Krystian     sensor specs update     use_level changed from [spare] to []    
Sep 25 2022 00:28:48     Kopka, Krystian     sensor specs update     last_cal_date changed from [2020-02-16 00:00:00+00:00] to [2022-01-25 00:00:00+00:00]    
Sep 07 2022 18:14:10     Greto, Carmen     sensor specs update     sensor_name changed from [SBE 04_4367] to [Conductivity SBE 04_4367]    
Dec 16 2021 21:26:59     Greto, Carmen     sensor specs update     transmit_rate_hz changed from [None] to [1.0]    
Dec 16 2021 21:26:59     Greto, Carmen     sensor specs update     packet_rate_hz changed from [None] to [1.0]    
Dec 16 2021 21:26:59     Greto, Carmen     sensor specs update     configuration changed from [] to [Configured with SBE cable171669]    
Dec 16 2021 21:26:59     Greto, Carmen     sensor specs update     current_reference_volts changed from [None] to [14.0]    
Dec 16 2021 21:26:59     Greto, Carmen     sensor specs update     current_max_milliamps changed from [None] to [12.0]    
Dec 16 2021 21:26:59     Greto, Carmen     sensor specs update     current_min_milliamps changed from [None] to [12.0]    
Dec 15 2021 19:06:23     Greto, Carmen     sensor specs update     acquire_condition changed from [] to [excellent]    
Dec 15 2021 19:06:23     Greto, Carmen     sensor specs update     acquire_date changed from [None] to [2014-01-01 00:00:00+00:00]    
Dec 15 2021 19:06:23     Greto, Carmen     sensor specs update     purchase_date changed from [None] to [2014-01-01 00:00:00+00:00]    
Dec 15 2021 19:01:12     Greto, Carmen     sensor specs update     time_source changed from [] to [vessel_time_server]    
Dec 15 2021 19:01:12     Greto, Carmen     sensor specs update     use_level changed from [] to [spare]    
Dec 15 2021 19:01:12     Greto, Carmen     sensor specs update     sensor_orientation changed from [] to [horizontal]    
Dec 15 2021 19:01:12     Greto, Carmen     sensor specs update     location_text changed from [] to [Not Applicable]    
Dec 15 2021 19:01:12     Greto, Carmen     sensor specs update     condition changed from [] to [good]    
Dec 15 2021 19:01:12     Greto, Carmen     sensor specs update     current_status changed from [] to [not in use]    
Dec 15 2021 19:01:12     Greto, Carmen     sensor specs update     current_location changed from [] to [on vessel]    
Dec 15 2021 19:01:12     Greto, Carmen     sensor specs update     response_time_seconds changed from [None] to [0.06]    
Dec 15 2021 19:01:12     Greto, Carmen     sensor specs update     depth_max_meters changed from [None] to [6800]    
Dec 15 2021 19:01:12     Greto, Carmen     sensor specs update     depth_min_meters changed from [None] to [0]    
Dec 15 2021 19:01:12     Greto, Carmen     sensor specs update     analog_units changed from [] to [Hertz]    
Dec 15 2021 19:01:12     Greto, Carmen     sensor specs update     analog_max changed from [None] to [7500]    
Dec 15 2021 19:01:12     Greto, Carmen     sensor specs update     analog_min changed from [None] to [2500]    
Dec 15 2021 19:01:12     Greto, Carmen     sensor specs update     power_current_type changed from [] to [DC]    
Dec 15 2021 19:01:12     Greto, Carmen     sensor specs update     power_max_volts changed from [None] to [24]    
Dec 15 2021 19:01:12     Greto, Carmen     sensor specs update     power_min_volts changed from [None] to [6]    
Dec 15 2021 19:01:12     Greto, Carmen     sensor specs update     native_type changed from [] to [text]    
Dec 15 2021 19:01:12     Greto, Carmen     sensor specs update     native_data_description changed from [] to [Square-wave variable ... nding to 0 to 7 S/m)]    
Dec 15 2021 19:01:12     Greto, Carmen     sensor specs update     sample_rate_hz changed from [None] to [24.0]    
Dec 15 2021 19:01:12     Greto, Carmen     sensor specs update     comm_type changed from [] to [Frequency]    
Dec 15 2021 19:01:12     Greto, Carmen     sensor specs update     signal_type changed from [] to [Analog]    
Dec 15 2021 19:01:12     Greto, Carmen     sensor specs update     model changed from [SBE 4C-1] to [Sea-Bird SBE 4C conductivity sensor]    
Dec 15 2021 19:01:12     Greto, Carmen     sensor specs update     vendor changed from [Sea-Bird Scientific (Sea-Bird Electronics)] to [Sea-Bird Scientific (Sea-Bird Electronics) ]    
Dec 15 2021 19:01:12     Greto, Carmen     sensor specs update     sensor_name changed from [Conductivity - ctd] to [SBE 04_4367]    
Feb 12 2021 01:43:39     Roberts, Steve     sensor specs update     responsible_party changed from [] to [UAF Marine Technicians]    
Feb 12 2021 01:43:39     Roberts, Steve     sensor specs update     owner changed from [] to [UAF]    
Feb 11 2021 23:58:42     Roberts, Steve     new sensor     Initial submission of sensor metadata.    
 
Calibration & Maintenance

Frequency Last Completed Next Due
Maintenance A:
 
Maintenance B:
 
Maintenance C: test001
 
Calibration
  12 months Jul 23 2024 Jul 23 2025
Recommended Replacement
 
Warranty
 
 
Calibration Files

Date Version Author Type Document Access
Jul 23 2024        Seabird   cal_file   Conductivity SBE 04 4367 CAL
Jul 23 2024        Seabird   cal_file   Conductivity SBE 04 4367 PDF
Jul 23 2024        Seabird   cal_file   Conductivity SBE 04 4367 XML
Jan 25 2022           cal_file   Conductivity SBE 04_4367 CAL
Jan 25 2022           cal_file   Conductivity SBE 04_4367 XML
Feb 16 2020           cal_file   Conductivity SBE 04_4367 CAL
Feb 16 2020           cal_file   Conductivity SBE 04_4367 XML
Dec 26 2018           cal_file   Conductivity SBE 04_4367 CAL
Dec 26 2018           cal_file   Conductivity SBE 04_4367 XML
Jan 17 2017           cal_file   Conductivity SBE 04_4367 CAL
Jan 17 2017           cal_file   Conductivity SBE 04_4367 XML
Dec 09 2015           cal_file   Conductivity SBE 04_4367 CAL
Dec 09 2015           cal_file   Conductivity SBE 04_4367 XML
 
 
User Guides & Documents

Date Version Author Type Document Access
Feb 08 2014           reference_sheet   Conductivity SBE 04_4367 Pres_Test
 
 
Ownership

Quantity Value
Owner UAF
Responsible Party UAF Marine Technicians
Purchase Date Jan 01 2014
Acquire Date Jan 01 2014
Acquire Condition excellent
End/Lost Ownership Date
 
Vendor Support

Support Type Details
Company Sea-Bird Scientific (Sea-Bird Electronics)
Website http://www.seabird.com
Phone +1 425 643 9866
Email techsupport@seabird.com
Shipping Sea-Bird Scientific, 13431 NE 20th Street, Bellevue, Washington 98005, USA
 
Copyright Notice: All sensor-specific images and documentation on this page are copyright of the vendor.
 
 
OSU logo NSF logo RCRV logo
RCRV Datapresence and Engineering Support Center
Oregon State University
Corvallis, OR 97331, USA