Anemometer Gill_1005

Summary



TypeAnemometer
VendorGill Instruments Ltd.
ModelGill Instruments WindObserver 75 (heated) anemometer
S/N1351005
ID Prefixanem2d
CORIOLIX IDanemom351005
ClassAtmospheric
LocationTech Stores
Conditiongood
Configuration
Native Sample Rate1.0 Hz
UDP Port(s)53124 None
EnabledFalse
 


Image Not Available
 
 

General Description



The WindObserver 75 has been developed for measuring higher wind speeds in extreme weather environments featuring 150 Watts of electrical heating power in the anemometer head. This anemometer has been designed to remain ice free in most freezing weather conditions. The sensor provides data via RS422/RS485 bidirectional link, which allows several units to be networked together and data logged on demand.

 
 

Data Collection Specs

Native Data Feed
Signal Type Analog
Communication Type RS-232
Serial Details
Baud Rate 9600
Parity N
Stop Bits 1
Byte Size 8
Timeout (s) None
Polled Start Commands None
Polled Serial Commands
Ethernet Details
MAC Address
IP Address 10.3.0.124
Protocol udp
Source File Details
Path
Filename
Native Data Format
Native Data Description Example data line: anemom351005 wind_gill_fwdmast 2022-11-05T00:00:00.3443Z A,063,006.29,M,60,00 ***** Field Description: Coriolix Sensor ID, LDS Logger ID, LDS Time Stamp [UTC], Unit ID, Wind direction (degrees, ship relative), Wind speed (knots), units(m/s), status, 0 = OK, 60 or 66 = Heating enabled and OK, others = warning or fault, checksum
Native Data Type text
Start of Message Characters
End of Message Characters
Sample Data Message #A,203,000.59,M,60,#05 #A,203,000.57,M,60,#0B #A,202,000.60,M,60,#0E
Message Parser Format ['^\W(?P<unit_id>\w+),(?P<direction>\d+),(?P<speed>\d+\.\d+),(?P<units>\w),(?P<heating_status>\d+),\W(?P<checksum>[0-9A-F]{2})$']
Data Processing
Data Processing Script Anemo2D
Data Rates
Native Sample Rate 1.0 Hz
Shipboard Network Packet Rate 1.0 Hz
Ship to Shore Rate 1.0 Hz
Data Storage & Access
Raw Data Ethernet Distribution
IP Address 10.3.0.255
Port 53124
Packet Size None
Transformed Data Ethernet Distribution
IP Address
Port None
Archive to Database True
Transmit Real-time Data to Shore False
Time Source
Source local_time_server
 

Parameters


Quantity Rel Wind Dir (degrees) Rel Wind Spd (m/s) True Wind Dir (degrees_true) True Wind Spd (m/s) True Wind u (m/s) True Wind v (m/s)
Plot Color
 
 
 
 
 
 
Parameter Full Name Relative Wind Direction Relative Wind Speed True Wind Direction True Wind Speed True Wind Velocity - u True Wind Velocity - v
Parameter Short Name Rel Wind Dir Rel Wind Spd True Wind Dir True Wind Spd True Wind u True Wind v
Parameter Standard Name ERWDSS01 ERWSSS01 EGTDSS01 EWSBSS01 XXXXXX XXXXXX
SAMOS Data Category Relative Wind Direction Relative Wind Speed True Wind Direction True Wind Speed
Description Wind direction relative to the vessel. Wind speed relative to the vessel. Derived true wind direction (from) in degrees clockwise from true North. Derived true wind speed in m/s. The u-component of the true wind velocity in m/s. The v-component of the true wind velocity in m/s.
Processing Status raw raw post processed with ancillary data post processed with ancillary data post processed with ancillary data post processed with ancillary data
Processing Symbol direction speed true_direction true_speed u v
Diagnostic False False False False False False
IOOS Category Wind Wind Wind Wind Wind Wind
Units degrees m/s degrees_true m/s m/s m/s
Data Type ushort float float float float float
Gross Minimum Value 0.0 degrees None m/s 0.0 degrees_true None m/s None m/s None m/s
Gross Maximum Value 360.0 degrees None m/s 360.0 degrees_true None m/s None m/s None m/s
Recommended Minimum Value None degrees None m/s None degrees_true None m/s None m/s None m/s
Recommended Maximum Value None degrees None m/s None degrees_true None m/s None m/s None m/s
Global Minimum Value None degrees 0.0 m/s None degrees_true 0.0 m/s None m/s None m/s
Global Maximum Value None degrees 100.0 m/s None degrees_true 100.0 m/s None m/s None m/s
Local Minimum Value None degrees None m/s None degrees_true None m/s None m/s None m/s
Local Maximum Value None degrees None m/s None degrees_true None m/s None m/s None m/s
Lower Detection Limit None degrees None m/s None degrees_true None m/s None m/s None m/s
Saturated Value None degrees None m/s None degrees_true None m/s None m/s None m/s
Bad Data Value None degrees None m/s None degrees_true None m/s None m/s None m/s
Resolution 1.0 degrees None m/s None degrees_true None m/s None m/s None m/s
Accuracy +/- None degrees +/- None m/s +/- None degrees_true +/- None m/s +/- None m/s +/- None m/s
Precision None degrees None m/s None degrees_true None m/s None m/s None m/s
Binning Type circular linear circular linear linear linear
Online Display Format 3.0f 5.2f 5.1f 5.2f 5.2f 5.2f
Logging Modes
 

Physical Sensor Specs

Operating Limits
Input Power 9.0 - 30.0 V DC
Ideal Power None V DC
Operating Current 50.0 - 50.0 mA @ 12.0 V DC
Analog Output None - None
Operating Flow Rate None - None ml s-1
Ideal Flow Rate None ml s-1
Operating Depth None - None m
Operating Temperature None - None degree_C
Lamp Life None days
Response Time None seconds
Additional Time Offset None seconds
Physical Status
Current Location on vessel
Current Status not in use
Physical Condition good
Physical Configuration
Software Version
Software Configuration
Data Acquisition Device ID
Data Acquisition Device Serial Port
Data Acquisition Device Analog/Digital Port(s)
Data Acquisition Device Modbus Unit None
Sensor Use Level
Enabled False
Vessel Installation Location
Vessel sikuliaq
Vessel Location Tech Stores
Location Coordinates (meters)
Sensor Orientation vertical up
Height Above Waterline (meters) 15.5
Zero Line Reference (degrees from bow) 0.0
Receives Filtered Water False
 

Maintenance & Support

Sensor Log

    Date (UTC)     Submitter     Event Type     Details        
Jun 08 2024 19:15:10     Grischuk, Jenny     sensor specs update     use_level changed from [primary] to []    
Jun 08 2024 19:15:10     Grischuk, Jenny     sensor specs update     location_text changed from [Forward Mast] to [Tech Stores]    
Jun 08 2024 19:15:10     Grischuk, Jenny     sensor specs update     enabled changed from [True] to [False]    
Jun 08 2024 19:15:10     Grischuk, Jenny     sensor specs update     current_status changed from [in use] to [not in use]    
Jun 08 2024 19:15:10     Grischuk, Jenny     sensor specs update     current_location changed from [installed] to [on vessel]    
Mar 10 2023 06:24:08     Naber, Daniel     sensor specs update     native_data_description changed from [Example data line: ... or fault, checksum] to [Example data line: ... or fault, checksum]    
Mar 08 2023 06:25:23     Naber, Daniel     sensor specs update     height_above_waterline changed from [None] to [15.5]    
Mar 08 2023 06:25:23     Naber, Daniel     sensor specs update     native_data_description changed from [Example data line: ... or fault, checksum] to [Example data line: ... or fault, checksum]    
Mar 07 2023 02:15:44     Naber, Daniel     sensor specs update     transmit_ip changed from [10.5.0.255] to [10.3.0.255]    
Mar 07 2023 02:15:44     Naber, Daniel     sensor specs update     time_source changed from [] to [local_time_server]    
Mar 07 2023 02:15:44     Naber, Daniel     sensor specs update     native_data_description changed from [] to [Example data line: ... or fault, checksum]    
Mar 07 2023 02:15:44     Naber, Daniel     sensor specs update     sensor_ethernet_protocol changed from [] to [udp]    
Mar 07 2023 02:15:44     Naber, Daniel     sensor specs update     sensor_ip changed from [] to [10.3.0.124]    
Mar 03 2023 22:35:32     Nahorniak, Jasmine     sensor specs update     transmit_rate_hz changed from [None] to [1.0]    
Mar 03 2023 22:35:32     Nahorniak, Jasmine     sensor specs update     packet_rate_hz changed from [None] to [1.0]    
Mar 03 2023 22:35:32     Nahorniak, Jasmine     sensor specs update     text_regex_format changed from [['^(?P<unit_id>\w+), ... ksum>[0-9A-F]{2})$']] to [['^\W(?P<unit_id>\w+ ... ksum>[0-9A-F]{2})$']]    
Mar 03 2023 22:35:32     Nahorniak, Jasmine     sensor specs update     sample_data_message changed from [A,203,000.59,M,60,05 ... A,202,000.60,M,60,0E] to [#A,203,000.59,M,60,# ... ,202,000.60,M,60,#0E]    
Mar 03 2023 22:35:32     Nahorniak, Jasmine     sensor specs update     sample_rate_hz changed from [None] to [1.0]    
Mar 03 2023 22:35:32     Nahorniak, Jasmine     sensor specs update     sensor_prefix changed from [] to [anem2d]    
Mar 03 2023 21:06:10     Nahorniak, Jasmine     sensor specs update     zero_line_reference changed from [None] to [0.0]    
Mar 03 2023 21:06:10     Nahorniak, Jasmine     sensor specs update     text_regex_format changed from [['^\W(?P<unit_id>\w+ ... ksum>[0-9A-F]{2})$']] to [['^(?P<unit_id>\w+), ... ksum>[0-9A-F]{2})$']]    
Mar 03 2023 21:06:10     Nahorniak, Jasmine     sensor specs update     sample_data_message changed from [#A,203,000.59,M,60,# ... ,202,000.60,M,60,#0E] to [A,203,000.59,M,60,05 ... A,202,000.60,M,60,0E]    
Feb 07 2023 18:42:18     Nahorniak, Jasmine     sensor specs update     retransmit_port changed from [54124] to [None]    
Feb 07 2023 18:42:18     Nahorniak, Jasmine     sensor specs update     retransmit_ip changed from [10.5.0.255] to []    
Feb 07 2023 18:42:18     Nahorniak, Jasmine     sensor specs update     time_source changed from [vessel_time_server] to []    
Feb 07 2023 18:42:18     Nahorniak, Jasmine     sensor specs update     use_level changed from [] to [primary]    
Jan 24 2023 23:50:52     Greto, Carmen     sensor specs update     current_reference_volts changed from [None] to [12.0]    
Jan 24 2023 23:50:52     Greto, Carmen     sensor specs update     current_max_milliamps changed from [None] to [50.0]    
Jan 24 2023 23:50:52     Greto, Carmen     sensor specs update     current_min_milliamps changed from [None] to [50.0]    
Jan 24 2023 23:50:52     Greto, Carmen     sensor specs update     power_current_type changed from [AC] to [DC]    
Jan 24 2023 23:50:52     Greto, Carmen     sensor specs update     power_max_volts changed from [None] to [30.0]    
Jan 24 2023 23:50:52     Greto, Carmen     sensor specs update     power_min_volts changed from [None] to [9.0]    
Jan 24 2023 02:08:06     Greto, Carmen     sensor specs update     processing_script changed from [] to [Anemo2D]    
Jan 24 2023 02:08:06     Greto, Carmen     sensor specs update     text_regex_format changed from [] to [^(?P<unit_id>\w+),(? ... ecksum>[0-9A-F]{2})$]    
Jan 24 2023 02:08:06     Greto, Carmen     sensor specs update     sample_data_message changed from [] to [wind_gill_fwdmast 20 ... A,202,000.60,M,60,0E]    
Jan 24 2023 01:52:08     Greto, Carmen     sensor specs update     native_type changed from [] to [text]    
Jan 24 2023 01:52:08     Greto, Carmen     sensor specs update     serial_bytesize changed from [] to [8]    
Jan 24 2023 01:52:08     Greto, Carmen     sensor specs update     serial_stop_bits changed from [] to [1]    
Jan 24 2023 01:52:08     Greto, Carmen     sensor specs update     serial_parity changed from [] to [N]    
Jan 24 2023 01:52:08     Greto, Carmen     sensor specs update     serial_baud_rate changed from [] to [9600]    
Jan 24 2023 01:52:08     Greto, Carmen     sensor specs update     comm_type changed from [] to [RS-232]    
Jan 24 2023 01:52:08     Greto, Carmen     sensor specs update     signal_type changed from [] to [Analog]    
Jan 23 2023 15:11:06     Greto, Carmen     sensor specs update     retransmit_port changed from [53124] to [54124]    
Jan 23 2023 15:11:06     Greto, Carmen     sensor specs update     transmit_port changed from [54124] to [53124]    
Jan 23 2023 15:11:06     Greto, Carmen     sensor specs update     transmit_ip changed from [10.3.0.255] to [10.5.0.255]    
Jan 23 2023 14:25:55     Greto, Carmen     sensor specs update     retransmit_port changed from [None] to [53124]    
Jan 23 2023 14:25:55     Greto, Carmen     sensor specs update     retransmit_ip changed from [] to [10.5.0.255]    
Jan 23 2023 14:25:55     Greto, Carmen     sensor specs update     transmit_ip changed from [10.5.0.255] to [10.3.0.255]    
Jan 23 2023 14:17:22     Greto, Carmen     sensor specs update     transmit_native changed from [True] to [False]    
Jan 10 2023 22:21:58     Greto, Carmen     sensor specs update     transmit_native changed from [False] to [True]    
Jan 10 2023 22:21:58     Greto, Carmen     sensor specs update     retransmit_port changed from [54124] to [None]    
Jan 10 2023 22:21:58     Greto, Carmen     sensor specs update     retransmit_ip changed from [10.5.0.255] to []    
Jan 10 2023 22:21:58     Greto, Carmen     sensor specs update     transmit_port changed from [53124] to [54124]    
Jan 08 2023 16:54:39     Greto, Carmen     sensor specs update     transmit_native changed from [True] to [False]    
Oct 27 2022 00:12:00     Kopka, Krystian     sensor specs update     current_status changed from [not in use] to [in use]    
Oct 27 2022 00:12:00     Kopka, Krystian     sensor specs update     current_location changed from [on vessel] to [installed]    
Oct 23 2022 01:46:47     Greto, Carmen     new sensor     Initial submission of sensor metadata.    
 
Calibration & Maintenance

Frequency Last Completed Next Due
Maintenance A:
 
Maintenance B:
 
Maintenance C:
 
Calibration
  Dec 20 2013
Recommended Replacement
 
Warranty
 
 
Calibration Files

Date Version Author Type Document Access
Dec 20 2013           cal_file   Anemometer Gill_1005 CAL
 
 
User Guides & Documents

Date Version Author Type Document Access
Jan 01 2022        Gill   datasheet   Anemometer Gill Wind Observer
 
 
Ownership

Quantity Value
Owner UAF
Responsible Party UAF Marine Technicians
Purchase Date
Acquire Date
Acquire Condition
End/Lost Ownership Date
 
Vendor Support

Support Type Details
Company Gill Instruments Ltd.
Website http://gillinstruments.com
Phone +44 (0)1590 613548
Email murree.sims@gillinstruments.com
Shipping Gill Instruments Ltd., Saltmarsh Park, 67 Gosport Street, Lymington, Hants, SO41 9EG, United Kingdom
 
Copyright Notice: All sensor-specific images and documentation on this page are copyright of the vendor.
 
 
OSU logo NSF logo RCRV logo
RCRV Datapresence and Engineering Support Center
Oregon State University
Corvallis, OR 97331, USA