ADCP WH300_xducer_depth

Summary



TypeADCP
VendorTeledyne (RDI)
ModelTeledyne RDI 300 kHz narrowband vessel-mounted ADCP
S/NXXXX
ID Prefixadcp
CORIOLIX IDadcpwhdepth
ClassSonar
LocationCenterboard
Conditiongood
ConfigurationWH300 installed on the bottom of the centerboard.
Native Sample RateNone Hz
UDP Port(s)55007 None
EnabledTrue
 


Image Not Available
 
 

General Description



300 kHz Acoustic Doppler Current Profiler. 154 meter profiling range. 253 meter bottom tracking ability. Pressure sensor installed. ***NOTE: This is an ancillary data set using the installed pressure sensor to determine the bottom position of the centerboard; SAFE (recessed 0.6 meters above ship's hull), FLUSH with ship's hull(6.0 meters below average water line) or DEPLOYED (8.2 meters below average water line).

 
 

Data Collection Specs

Native Data Feed
Signal Type Digital
Communication Type Ethernet
Serial Details
Baud Rate
Parity
Stop Bits
Byte Size
Timeout (s) None
Polled Start Commands
Polled Serial Commands
Ethernet Details
MAC Address
IP Address
Protocol udp
Source File Details
Path
Filename
Native Data Format
Native Data Description Example data line: $PMSG,8021*21 ***** Field Description: NMEA ID, Depth [Meters] i.e, 8021 = 8.021 meters, CheckSum
Native Data Type text
Start of Message Characters
End of Message Characters
Sample Data Message $PMSG,8846*27
Message Parser Format ['^\WPMSG,(?P<depth>\d+)\*(?P<checksum>[0-9A-F]{2})$']
Data Processing
Data Processing Script NoTransformation
Data Rates
Native Sample Rate None Hz
Shipboard Network Packet Rate None Hz
Ship to Shore Rate None Hz
Data Storage & Access
Raw Data Ethernet Distribution
IP Address 10.3.0.255
Port 55007
Packet Size None
Transformed Data Ethernet Distribution
IP Address
Port None
Archive to Database True
Transmit Real-time Data to Shore True
Time Source
Source local_time_server
 

Parameters


Quantity Centerboard Depth (mm)
Plot Color
 
Parameter Full Name Centerboard Depth
Parameter Short Name Centerboard Depth
Parameter Standard Name XXXXXX
SAMOS Data Category
Description A pressure sensor on the WH300 ADCP is used to determine the positon of the centerboard; SAFE position (recessed 0.6 meters above ship's hull), FLUSH with ship's hull (6.0 meters below average water line) or DEPLOYED position (8.2 meters below average water line).
Processing Status raw
Processing Symbol depth
Diagnostic False
IOOS Category Other
Units mm
Data Type ushort
Gross Minimum Value None mm
Gross Maximum Value None mm
Recommended Minimum Value None mm
Recommended Maximum Value None mm
Global Minimum Value None mm
Global Maximum Value None mm
Local Minimum Value None mm
Local Maximum Value None mm
Lower Detection Limit None mm
Saturated Value None mm
Bad Data Value None mm
Resolution None mm
Accuracy +/- None mm
Precision None mm
Binning Type spot
Online Display Format 4.0f
Logging Modes
 

Physical Sensor Specs

Operating Limits
Input Power None - None V AC
Ideal Power None V AC
Operating Current None - None mA @ None V AC
Analog Output None - None
Operating Flow Rate None - None ml s-1
Ideal Flow Rate None ml s-1
Operating Depth None - None m
Operating Temperature None - None degree_C
Lamp Life None days
Response Time None seconds
Additional Time Offset None seconds
Physical Status
Current Location installed
Current Status in use
Physical Condition good
Physical Configuration WH300 installed on the bottom of the centerboard.
Software Version
Software Configuration
Data Acquisition Device ID
Data Acquisition Device Serial Port
Data Acquisition Device Analog/Digital Port(s)
Data Acquisition Device Modbus Unit None
Sensor Use Level primary
Enabled True
Vessel Installation Location
Vessel sikuliaq
Vessel Location Centerboard
Location Coordinates (meters)
Sensor Orientation vertical down
Height Above Waterline (meters) None
Zero Line Reference (degrees from bow) None
Receives Filtered Water False
 

Maintenance & Support

Sensor Log

    Date (UTC)     Submitter     Event Type     Details        
Oct 05 2024 21:31:28     Nahorniak, Jasmine     sensor specs update     model changed from [Teledyne RDI 300kHz Narrowband Vessel-Mounted ADCP] to [Teledyne RDI 300 kHz ... vessel-mounted ADCP]    
Mar 18 2024 16:07:31     Nahorniak, Jasmine     sensor specs update     native_data_description changed from [Example data line: ... 1 meters, CheckSum] to [Example data line: ... 1 meters, CheckSum]    
Mar 18 2024 16:07:31     Nahorniak, Jasmine     sensor specs update     comm_type changed from [] to [Ethernet]    
Mar 18 2024 16:07:31     Nahorniak, Jasmine     sensor specs update     signal_type changed from [] to [Digital]    
Feb 19 2024 02:01:39     Nahorniak, Jasmine     sensor specs update     use_level changed from [] to [primary]    
Feb 19 2024 02:01:39     Nahorniak, Jasmine     sensor specs update     enabled changed from [False] to [True]    
Feb 19 2024 02:01:39     Nahorniak, Jasmine     sensor specs update     processing_script changed from [] to [NoTransformation]    
Feb 19 2024 02:01:39     Nahorniak, Jasmine     sensor specs update     sensor_prefix changed from [] to [adcp]    
Jun 02 2023 22:16:33     Greto, Carmen     sensor specs update     enabled changed from [True] to [False]    
Mar 31 2023 05:43:33     Naber, Daniel     sensor specs update     configuration changed from [] to [WH300 installed on the bottom of the centerboard.]    
Mar 31 2023 05:43:33     Naber, Daniel     sensor specs update     native_type changed from [] to [text]    
Mar 31 2023 05:43:33     Naber, Daniel     sensor specs update     native_data_description changed from [Example data line: ... 1 meters, CheckSum] to [Example data line: ... 1 meters, CheckSum]    
Mar 31 2023 05:43:33     Naber, Daniel     sensor specs update     sensor_ethernet_protocol changed from [] to [udp]    
Mar 31 2023 05:43:33     Naber, Daniel     sensor specs update     description changed from [300 kHz Acoustic Dop ... CP WH300 is mounted.] to [300 kHz Acoustic Dop ... average water line).]    
Mar 31 2023 05:29:36     Naber, Daniel     new sensor     Initial submission of sensor metadata.    
 
Calibration & Maintenance

Frequency Last Completed Next Due
Maintenance A:
 
Maintenance B:
 
Maintenance C:
 
Calibration
 
Recommended Replacement
 
Warranty
 
 
Calibration Files

Date Version Author Type Document Access
 
 
User Guides & Documents

Date Version Author Type Document Access
 
 
Ownership

Quantity Value
Owner UAF
Responsible Party UAF Marine Technicians
Purchase Date
Acquire Date
Acquire Condition
End/Lost Ownership Date
 
Vendor Support

Support Type Details
Company Teledyne (RDI)
Website http://www.teledynemarine.com/oceanography/
Phone +1-858-842-2600
Email rdifs@teledyne.com
Shipping
 
Copyright Notice: All sensor-specific images and documentation on this page are copyright of the vendor.
 
 
OSU logo NSF logo RCRV logo
RCRV Datapresence and Engineering Support Center
Oregon State University
Corvallis, OR 97331, USA