ADCP OS150_1866

Summary



TypeADCP
VendorTeledyne (RDI)
ModelTeledyne RDI Ocean Surveyor 150kHz vessel-mounted ADCP
S/N1866
ID Prefix
CORIOLIX IDadcpos001866
ClassSonar
LocationHull
Conditioninoperable
ConfigurationP/N: 71A-1036-00 TCM2: no
Native Sample RateNone Hz
UDP Port(s)None None
EnabledFalse
 


Image Not Available
 
 

General Description



150 kHz Phased Array Acoustic Doppler Current Profiler. 400 meter profiling range. 540 meter bottom tracking ability.

 
 

Data Collection Specs

Native Data Feed
Signal Type
Communication Type
Serial Details
Baud Rate
Parity
Stop Bits
Byte Size
Timeout (s) None
Polled Serial Commands
Ethernet Details
MAC Address
IP Address
Protocol
Source File Details
Path
Filename
Native Data Format
Native Data Description
Native Data Type
Start of Message Characters
End of Message Characters
Sample Data Message
Message Parser Format
Data Processing
Data Processing Script
Data Rates
Native Sample Rate None Hz
Shipboard Network Packet Rate None Hz
Ship to Shore Rate None Hz
Data Storage & Access
Raw Data Ethernet Distribution
IP Address
Port None
Packet Size None
Transformed Data Ethernet Distribution
IP Address
Port None
Archive to Database False
Transmit Real-time Data to Shore False
Time Source
Source
 

Parameters


Quantity
Plot Color
Parameter Full Name
Parameter Short Name
Parameter Standard Name
SAMOS Data Category
Description
Processing Status
Processing Symbol
Diagnostic
IOOS Category
Units
Data Type
Gross Minimum Value
Gross Maximum Value
Recommended Minimum Value
Recommended Maximum Value
Global Minimum Value
Global Maximum Value
Local Minimum Value
Local Maximum Value
Lower Detection Limit
Saturated Value
Bad Data Value
Resolution
Accuracy
Precision
Binning Type
Online Display Format
Logging Modes
 

Physical Sensor Specs

Operating Limits
Input Power None - None V AC
Ideal Power None V AC
Operating Current None - None mA @ None V AC
Analog Output None - None
Operating Flow Rate None - None ml s-1
Ideal Flow Rate None ml s-1
Operating Depth 0 - 100 m
Operating Temperature None - None degree_C
Lamp Life None days
Response Time None seconds
Additional Time Offset None seconds
Physical Status
Current Location installed
Current Status testing in progress
Physical Condition inoperable
Resistance tests in 01/2024 indicate cable damage. Tests on the wet-end connector show the sonar is in working condition. OOC for now. -C.GRETO
Physical Configuration P/N: 71A-1036-00 TCM2: no
Software Version
Software Configuration
Data Acquisition Device ID
Data Acquisition Device Serial Port
Data Acquisition Device Analog/Digital Port(s)
Data Acquisition Device Modbus Unit None
Sensor Use Level
Enabled False
Vessel Installation Location
Vessel Sikuliaq
Vessel Location Hull
Location Coordinates (meters) 26.130, 3.994, 6.043
Sensor Orientation
Height Above Waterline (meters) None
Zero Line Reference (degrees from bow) None
Receives Filtered Water False
 

Maintenance & Support

Sensor Log

    Date (UTC)     Submitter     Event Type     Details        
Feb 05 2024 15:55:31     Greto, Carmen     sensor specs update     transmit_native changed from [True] to [False]    
Feb 05 2024 15:55:31     Greto, Carmen     sensor specs update     archive_native changed from [True] to [False]    
Feb 05 2024 15:55:31     Greto, Carmen     sensor specs update     condition_details changed from [Resistance checks in ... OC for now. -C.GRETO] to [Resistance tests in ... OC for now. -C.GRETO]    
Feb 05 2024 15:55:31     Greto, Carmen     sensor specs update     current_status changed from [repair in progress] to [testing in progress]    
Jan 31 2024 14:59:40     Greto, Carmen     sensor specs update     enabled changed from [True] to [False]    
Jan 31 2024 14:59:40     Greto, Carmen     sensor specs update     configuration changed from [P/N: 71A-1036 TCM2: no] to [P/N: 71A-1036-00 TCM2: no]    
Jan 31 2024 14:59:40     Greto, Carmen     sensor specs update     condition_details changed from [] to [Resistance checks in ... OC for now. -C.GRETO]    
Jan 31 2024 14:59:40     Greto, Carmen     sensor specs update     condition changed from [good] to [inoperable]    
Jan 31 2024 14:59:40     Greto, Carmen     sensor specs update     current_status changed from [in use] to [repair in progress]    
Jan 17 2024 15:51:56     Greto, Carmen     sensor specs update     configuration changed from [] to [P/N: 71A-1036 TCM2: no]    
Mar 28 2023 22:52:42     Naber, Daniel     sensor specs update     time_source changed from [vessel_time_server] to []    
Mar 28 2023 22:52:42     Naber, Daniel     sensor specs update     sensor_class changed from [Centerboard] to [Sonar]    
Feb 05 2023 15:57:00     Greto, Carmen     installation     test    
Oct 23 2022 03:28:19     Kopka, Krystian     sensor specs update     location_coords changed from [] to [26.130, 3.994, 6.043]    
Oct 19 2022 00:39:53     Greto, Carmen     sensor specs update     use_level changed from [primary] to []    
Oct 18 2022 18:38:44     Greto, Carmen     sensor specs update     enabled changed from [False] to [True]    
Sep 03 2022 23:41:40     Greto, Carmen     sensor specs update     configuration changed from [TEST] to []    
Sep 03 2022 23:40:21     Greto, Carmen     sensor specs update     configuration changed from [] to [TEST]    
May 22 2022 20:05:29     Greto, Carmen     sensor specs update     vendor changed from [Not Applicable] to [Teledyne (RDI)]    
May 22 2022 16:22:54     Greto, Carmen     sensor specs update     use_level changed from [] to [primary]    
May 22 2022 16:21:26     Greto, Carmen     sensor specs update     depth_max_meters changed from [None] to [100]    
May 22 2022 16:21:26     Greto, Carmen     sensor specs update     depth_min_meters changed from [None] to [0]    
May 22 2022 16:21:26     Greto, Carmen     sensor specs update     description changed from [150 kHz Phased Array ... er Current Profiler.] to [150 kHz Phased Array ... om tracking ability.]    
May 22 2022 15:29:56     Greto, Carmen     new sensor     Initial submission of sensor metadata.    
 
Calibration & Maintenance

Frequency Last Completed Next Due
Maintenance A:
 
Maintenance B:
 
Maintenance C: test001
 
Calibration
 
Recommended Replacement
 
Warranty
 
 
Calibration Files

Date Version Author Type Document Access
 
 
User Guides & Documents

Date Version Author Type Document Access
 
 
Ownership

Quantity Value
Owner UAF
Responsible Party UAF Marine Technicians
Purchase Date
Acquire Date
Acquire Condition
End/Lost Ownership Date
 
Vendor Support

Support Type Details
Company Teledyne (RDI)
Website http://www.teledynemarine.com/oceanography/
Phone +1-858-842-2600
Email rdifs@teledyne.com
Shipping
 
Copyright Notice: All sensor-specific images and documentation on this page are copyright of the vendor.
 
 
Data Visualization

Time-Series Plots
   Flowthrough
   Meteorological
   Navigation
   Combination
   Custom
Charting Tools
 
Data Access

Data Structure
Quality Flags
Long-term Archive (R2R)
Data Download
   Full Resolution
   Binned Data
Web Services
   Direct Access Overview
   RESTful API
   ERDDAP
Software Tools
   Python Tools
   Matlab Tools
   R Tools
   ArcGIS Tools
 
Science Party Tools

Cruise & Participants Lists
Event Log
 
OSU logo NSF logo RCRV logo