ADCP OS38_1090

Summary



TypeADCP
VendorTeledyne (RDI)
ModelTeledyne RDI Ocean Surveyor 38kHz ADCP
S/N1090
ID Prefix
CORIOLIX IDadcpos001090
ClassSonar
LocationHull
Conditiongood
ConfigurationP/N: 71A-1020-00 TCM2: yes
Native Sample RateNone Hz
UDP Port(s)None None
EnabledTrue
 


Image Not Available
 
 

General Description



38 kHz Phased Array Acoustic Doppler Current Profiler. 1000 meter profiling range. 1700 meter bottom tracking ability.

 
 

Data Collection Specs

Native Data Feed
Signal Type
Communication Type
Serial Details
Baud Rate
Parity
Stop Bits
Byte Size
Timeout (s) None
Polled Serial Commands
Ethernet Details
MAC Address
IP Address
Protocol
Source File Details
Path
Filename
Native Data Format
Native Data Description
Native Data Type
Start of Message Characters
End of Message Characters
Sample Data Message
Message Parser Format
Data Processing
Data Processing Script
Data Rates
Native Sample Rate None Hz
Shipboard Network Packet Rate None Hz
Ship to Shore Rate None Hz
Data Storage & Access
Raw Data Ethernet Distribution
IP Address
Port None
Packet Size None
Transformed Data Ethernet Distribution
IP Address
Port None
Archive to Database True
Transmit Real-time Data to Shore True
Time Source
Source
 

Parameters


Quantity
Plot Color
Parameter Full Name
Parameter Short Name
Parameter Standard Name
SAMOS Data Category
Description
Processing Status
Processing Symbol
Diagnostic
IOOS Category
Units
Data Type
Gross Minimum Value
Gross Maximum Value
Recommended Minimum Value
Recommended Maximum Value
Global Minimum Value
Global Maximum Value
Local Minimum Value
Local Maximum Value
Lower Detection Limit
Saturated Value
Bad Data Value
Resolution
Accuracy
Precision
Binning Type
Online Display Format
Logging Modes
 

Physical Sensor Specs

Operating Limits
Input Power None - None V AC
Ideal Power None V AC
Operating Current None - None mA @ None V AC
Analog Output None - None
Operating Flow Rate None - None ml s-1
Ideal Flow Rate None ml s-1
Operating Depth 0 - 100 m
Operating Temperature None - None degree_C
Lamp Life None days
Response Time None seconds
Additional Time Offset None seconds
Physical Status
Current Location installed
Current Status in use
Physical Condition good
Physical Configuration P/N: 71A-1020-00 TCM2: yes
Software Version
Software Configuration
Data Acquisition Device ID
Data Acquisition Device Serial Port
Data Acquisition Device Analog/Digital Port(s)
Data Acquisition Device Modbus Unit None
Sensor Use Level
Enabled True
Vessel Installation Location
Vessel Sikuliaq
Vessel Location Hull
Location Coordinates (meters) 24.880, 0.306, 6.046
Sensor Orientation
Height Above Waterline (meters) None
Zero Line Reference (degrees from bow) None
Receives Filtered Water False
 

Maintenance & Support

Sensor Log

    Date (UTC)     Submitter     Event Type     Details        
Jan 21 2024 02:35:28     Greto, Carmen     sensor specs update     software_version changed from [\] to []    
Jan 21 2024 02:35:10     Greto, Carmen     sensor specs update     software_version changed from [] to [\]    
Jan 21 2024 02:35:10     Greto, Carmen     sensor specs update     configuration changed from [P/N: 72A-1020 TCM2: yes] to [P/N: 71A-1020-00 TCM2: yes]    
Jan 17 2024 15:52:27     Greto, Carmen     sensor specs update     configuration changed from [] to [P/N: 72A-1020 TCM2: yes]    
Mar 28 2023 22:52:51     Naber, Daniel     sensor specs update     time_source changed from [vessel_time_server] to []    
Mar 28 2023 22:52:51     Naber, Daniel     sensor specs update     sensor_class changed from [Centerboard] to [Sonar]    
Oct 23 2022 03:29:02     Kopka, Krystian     sensor specs update     location_coords changed from [] to [24.880, 0.306, 6.046]    
Oct 20 2022 03:13:44     Kopka, Krystian     sensor specs update     use_level changed from [primary] to []    
Oct 20 2022 03:13:44     Kopka, Krystian     sensor specs update     enabled changed from [False] to [True]    
Oct 19 2022 23:31:04     Kopka, Krystian     sensor specs update     enabled changed from [True] to [False]    
Oct 16 2022 00:18:21     Kopka, Krystian     sensor specs update     enabled changed from [False] to [True]    
May 22 2022 20:05:47     Greto, Carmen     sensor specs update     vendor changed from [Not Applicable] to [Teledyne (RDI)]    
May 22 2022 16:37:22     Greto, Carmen     sensor specs update     model changed from [Teledyne RDI Ocean S ... vessel-mounted ADCP] to [Teledyne RDI Ocean Surveyor 38kHz ADCP]    
May 22 2022 16:32:38     Greto, Carmen     new sensor     Initial submission of sensor metadata.    
 
Calibration & Maintenance

Frequency Last Completed Next Due
Maintenance A:
 
Maintenance B:
 
Maintenance C:
 
Calibration
 
Recommended Replacement
 
Warranty
 
 
Calibration Files

Date Version Author Type Document Access
 
 
User Guides & Documents

Date Version Author Type Document Access
 
 
Ownership

Quantity Value
Owner UAF
Responsible Party UAF Marine Technicians
Purchase Date
Acquire Date
Acquire Condition
End/Lost Ownership Date
 
Vendor Support

Support Type Details
Company Teledyne (RDI)
Website http://www.teledynemarine.com/oceanography/
Phone +1-858-842-2600
Email rdifs@teledyne.com
Shipping
 
Copyright Notice: All sensor-specific images and documentation on this page are copyright of the vendor.
 
 
Data Visualization

Time-Series Plots
   Flowthrough
   Meteorological
   Navigation
   Combination
   Custom
Charting Tools
 
Data Access

Data Structure
Quality Flags
Long-term Archive (R2R)
Data Download
   Full Resolution
   Binned Data
Web Services
   Direct Access Overview
   RESTful API
   ERDDAP
Software Tools
   Python Tools
   Matlab Tools
   R Tools
   ArcGIS Tools
 
Science Party Tools

Cruise & Participants Lists
Event Log
 
OSU logo NSF logo RCRV logo