![]() |
ERDDAP
Easier access to scientific data |
|
Brought to you by NOAA NMFS SWFSC ERD |
| Dataset Title: | RV Sikuliaq : Flowmeter Krohne_1463 : Sea Water Electrical Conductivity : 600 s binned
|
| Institution: | UAF (Dataset ID: seawaterconductivity_sperm_flowme021463_600sbin) |
| Information: | Summary
| License
| Metadata
| Background
| Make a graph
|
Attributes {
s {
time {
String _CoordinateAxisType "Time";
String axis "T";
String ioos_category "Time";
String long_name "Time";
String standard_name "time";
String time_origin "01-JAN-1970 00:00:00";
String units "seconds since 1970-01-01T00:00:00Z";
}
spot_time {
String ioos_category "Time";
String long_name "Spot Time";
String time_origin "01-JAN-1970 00:00:00";
String units "seconds since 1970-01-01T00:00:00Z";
}
spot_value {
String ioos_category "Statistics";
String long_name "Sea Water Electrical Conductivity Spot_Value";
String short_name "sea_water_conductivity_spot_value";
String special_notes "Binning type: linear";
String standard_name "sea_water_electrical_conductivity_spot_value";
String units "S/m";
}
mean {
String ioos_category "Statistics";
String long_name "Sea Water Electrical Conductivity Mean";
String short_name "sea_water_conductivity_mean";
String special_notes "Binning type: linear";
String standard_name "sea_water_electrical_conductivity_mean";
String units "S/m";
}
stddev {
String ioos_category "Statistics";
String long_name "Sea Water Electrical Conductivity Stddev";
String short_name "sea_water_conductivity_stddev";
String special_notes "Binning type: linear";
String standard_name "sea_water_electrical_conductivity_stddev";
String units "S/m";
}
minimum {
String ioos_category "Statistics";
String long_name "Sea Water Electrical Conductivity Minimum";
String short_name "sea_water_conductivity_minimum";
String special_notes "Binning type: linear";
String standard_name "sea_water_electrical_conductivity_minimum";
String units "S/m";
}
maximum {
String ioos_category "Statistics";
String long_name "Sea Water Electrical Conductivity Maximum";
String short_name "sea_water_conductivity_maximum";
String special_notes "Binning type: linear";
String standard_name "sea_water_electrical_conductivity_maximum";
String units "S/m";
}
median {
String ioos_category "Statistics";
String long_name "Sea Water Electrical Conductivity Median";
String short_name "sea_water_conductivity_median";
String special_notes "Binning type: linear";
String standard_name "sea_water_electrical_conductivity_median";
String units "S/m";
}
num_values {
String ioos_category "Statistics";
String long_name "Sea Water Electrical Conductivity Num_Values";
String short_name "sea_water_conductivity_num_values";
String special_notes "Binning type: linear";
String standard_name "sea_water_electrical_conductivity_num_values";
String units "unitless";
}
}
NC_GLOBAL {
String cdm_data_type "Other";
String contributor_name "RV Sikuliaq";
String contributor_role "Data collector";
String creator_name "CORIOLIX, RDESC, RCRV Project, Oregon State University";
String creator_url "http://ceoas.oregonstate.edu";
String history
"2026-05-02T18:49:49Z (source database)
2026-05-02T18:49:49Z https://coriolix.sikuliaq.alaska.edu/erddap/tabledap/seawaterconductivity_sperm_flowme021463_600sbin.html";
String infoUrl "https://www.uaf.edu/cfos/sikuliaq/";
String institution "UAF";
String keywords "atmosphere, data, observations, ocean";
String license
"The data may be used and redistributed for free but is not intended
for legal use, since it may contain inaccuracies. Neither the data
Contributor, ERD, NOAA, nor the United States Government, nor any
of their employees or contractors, makes any warranty, express or
implied, including warranties of merchantability and fitness for a
particular purpose, or assumes any legal liability for the accuracy,
completeness, or usefulness, of this information.";
String sourceUrl "(source database)";
String standard_name_vocabulary "CF standard name";
String summary
"Sea Water Electrical Conductivity 600 s binned time series data.
Vessel: RV Sikuliaq. Sensor Model: Krohne Optiflux 5000 flow sensor
Sensor S/N: A13021463
Sensor Location Onboard: Main Lab / Wet Wall
Sensor Description: Electromagnetic Flowmeter measuring surface seawater flow being delivered to underway instruments. These electromagnetic flowmeters are designed exclusively to measure the flow and conductivity of electrically conductive, liquid media.
The interface to this instrument is via Modbus RTU over RS485. Custom software had to be written to extract the required data from the sensor. The logged data format is
unique to Sikuliaq.
Parameter Description: Measurement of flowthrough sea surface conductivity.";
String title "RV Sikuliaq : Flowmeter Krohne_1463 : Sea Water Electrical Conductivity : 600 s binned";
}
}
Data Access Protocol (DAP)
and its
selection constraints
.
The URL specifies what you want: the dataset, a description of the graph or the subset of the data, and the file type for the response.
Tabledap request URLs must be in the form
https://coastwatch.pfeg.noaa.gov/erddap/tabledap/datasetID.fileType{?query}
For example,
https://coastwatch.pfeg.noaa.gov/erddap/tabledap/pmelTaoDySst.htmlTable?longitude,latitude,time,station,wmo_platform_code,T_25&time>=2015-05-23T12:00:00Z&time<=2015-05-31T12:00:00Z
Thus, the query is often a comma-separated list of desired variable names,
followed by a collection of
constraints (e.g., variable<value),
each preceded by '&' (which is interpreted as "AND").
For details, see the tabledap Documentation.