NOAA ERDDAP
Easier access to scientific data
| ?    
Brought to you by NOAA NMFS SWFSC ERD    
 
 
Row Type Variable Name Attribute Name Data Type Value
attribute NC_GLOBAL cdm_data_type String Other
attribute NC_GLOBAL contributor_name String RV Sikuliaq
attribute NC_GLOBAL contributor_role String Data collector
attribute NC_GLOBAL creator_name String CORIOLIX, RDESC, RCRV Project, Oregon State University
attribute NC_GLOBAL creator_url String http://ceoas.oregonstate.edu (external link)
attribute NC_GLOBAL infoUrl String https://www.uaf.edu/cfos/sikuliaq/ (external link)
attribute NC_GLOBAL institution String UAF
attribute NC_GLOBAL keywords String atmosphere, data, observations, ocean
attribute NC_GLOBAL license String The data may be used and redistributed for free but is not intended\nfor legal use, since it may contain inaccuracies. Neither the data\nContributor, ERD, NOAA, nor the United States Government, nor any\nof their employees or contractors, makes any warranty, express or\nimplied, including warranties of merchantability and fitness for a\nparticular purpose, or assumes any legal liability for the accuracy,\ncompleteness, or usefulness, of this information.
attribute NC_GLOBAL sourceUrl String (source database)
attribute NC_GLOBAL standard_name_vocabulary String CF standard name
attribute NC_GLOBAL summary String Partial Pressure of Carbon Dioxide relative to the Source time series data.\nPlatform: RV Sikuliaq\nSensor Model: Lamont-Doherty Earth Observatory pCO2 underway system\nSensor S/N: LI-6251 IRG1-338\nSensor Location Onboard: Wet Lab\nSensor Description: LDEO pCO2 Seawater Sensor; a system for the underway continuous measurement of surface water pCO2. The pCO2 system consists of several major components; a seawater/air equilibrator, the analysis enclosure (LI-COR 6251 infrared gas analyzer (IR), gas dryer, pressure sensor, A/D modules and gas stream selection valve), computer for system control and data logging, an enclosure holding a pair of air pumps for delivering the sample gas streams, 5 cylinders of CO2 in air calibration mixtures, 1 cylinder of nitrogen gas.\nParameter Description: The pco2 computed with conditions relative to the source. Users should review the source_id to identify atmospheric, equilibrator, and standard values.
attribute NC_GLOBAL title String RV Sikuliaq : pCO2_LDEO : Partial Pressure of Carbon Dioxide relative to the Source
variable time_raw double
attribute time_raw ioos_category String Time
attribute time_raw long_name String Time Raw
attribute time_raw time_origin String 01-JAN-1970 00:00:00
attribute time_raw units String seconds since 1970-01-01T00:00:00Z
variable time double
attribute time _CoordinateAxisType String Time
attribute time axis String T
attribute time ioos_category String Time
attribute time long_name String Time
attribute time standard_name String time
attribute time time_origin String 01-JAN-1970 00:00:00
attribute time units String seconds since 1970-01-01T00:00:00Z
variable value double
attribute value ioos_category String CO2
attribute value long_name String Partial Pressure Of Carbon Dioxide Relative To The Source
attribute value parameter_description String The pco2 computed with conditions relative to the source. Users should review the source_id to identify atmospheric, equilibrator, and standard values.
attribute value short_name String source_pco2
attribute value standard_name String x
attribute value units String uatm
variable flag_summary int
attribute flag_summary colorBarMaximum String 9
attribute flag_summary colorBarMinimum String 0
attribute flag_summary flag_meanings String QC test not applicable, passed the QC test, quality was not evaluated or is unknown, quality is questionable/suspect, failed the QC test, data are missing
attribute flag_summary flag_values String 0, 1, 2, 3, 4, 9
attribute flag_summary ioos_category String Quality
attribute flag_summary long_name String Partial Pressure Of Carbon Dioxide Relative To The Source QC Summary Flag
attribute flag_summary short_name String source_pco2_qc_flag
attribute flag_summary standard_name String x_qc_flag
attribute flag_summary units String unitless
variable flag_string String
attribute flag_string flag_meanings String QC test not applicable, passed the QC test, quality was not evaluated or is unknown, quality is questionable/suspect, failed the QC test, data are missing
attribute flag_string flag_values String 0, 1, 2, 3, 4, 9
attribute flag_string ioos_category String Quality
attribute flag_string long_name String Partial Pressure Of Carbon Dioxide Relative To The Source QC Flags
attribute flag_string qc_test_indices String 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29
attribute flag_string qc_test_names String Gap Test, Syntax Test, Gross Range Test, Global Range Test, Recommended Range Test, Sensor Status Test, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused, Unused
attribute flag_string short_name String source_pco2_qc_flag_string
attribute flag_string standard_name String x_qc_flag_string
attribute flag_string units String unitless

 
ERDDAP, Version 2.23
Disclaimers | Privacy Policy | Contact