NOAA ERDDAP
Easier access to scientific data
| ?    
Brought to you by NOAA NMFS SWFSC ERD    
 
 
griddap Subset tabledap Make A Graph wms files Title Summary FGDC ISO 19115 Info Background Info RSS Email Institution Dataset ID
https://coriolix.sikuliaq.alaska.edu/erddap/tabledap/dissolvedoxygen_umolperl_oxygen003594_060sbin https://coriolix.sikuliaq.alaska.edu/erddap/tabledap/dissolvedoxygen_umolperl_oxygen003594_060sbin.graph RV Sikuliaq : Oxygen Aanderaa_3594 : Dissolved Oxygen Concentration : 1 minute binned Dissolved Oxygen Concentration 1-minute binned time series data.\nVessel: RV Sikuliaq. Sensor Model: Aanderaa 4330 oxygen optode\nSensor S/N: 3594\nSensor Location Onboard: Main Lab / Wet Wall\nSensor Description: The Oxygen Optode is an optical sensor that does not consume oxygen. The measurement principle is based on fluorescence quenching, while traditional polorographic oxygen sensors, often called Clark sensors, based on electrochemical principles consume oxygen.\nParameter Description:\n\ncdm_data_type = Other\nVARIABLES:\ntime (seconds since 1970-01-01T00:00:00Z)\nspot_time (seconds since 1970-01-01T00:00:00Z)\nspot_value (Dissolved Oxygen Concentration Spot_Value, umol/l)\nmean (Dissolved Oxygen Concentration Mean, umol/l)\nstddev (Dissolved Oxygen Concentration Stddev, umol/l)\nminimum (Dissolved Oxygen Concentration Minimum, umol/l)\nmaximum (Dissolved Oxygen Concentration Maximum, umol/l)\nmedian (Dissolved Oxygen Concentration Median, umol/l)\nnum_values (Dissolved Oxygen Concentration Num_Values, unitless)\n https://coriolix.sikuliaq.alaska.edu/erddap/info/dissolvedoxygen_umolperl_oxygen003594_060sbin/index.htmlTable https://www.uaf.edu/cfos/sikuliaq/ (external link) https://coriolix.sikuliaq.alaska.edu/erddap/rss/dissolvedoxygen_umolperl_oxygen003594_060sbin.rss https://coriolix.sikuliaq.alaska.edu/erddap/subscriptions/add.html?datasetID=dissolvedoxygen_umolperl_oxygen003594_060sbin&showErrors=false&email= UAF dissolvedoxygen_umolperl_oxygen003594_060sbin
https://coriolix.sikuliaq.alaska.edu/erddap/tabledap/dissolvedoxygen_umolperl_oxygen003594_600sbin https://coriolix.sikuliaq.alaska.edu/erddap/tabledap/dissolvedoxygen_umolperl_oxygen003594_600sbin.graph RV Sikuliaq : Oxygen Aanderaa_3594 : Dissolved Oxygen Concentration : 600 s binned Dissolved Oxygen Concentration 600 s binned time series data.\nVessel: RV Sikuliaq. Sensor Model: Aanderaa 4330 oxygen optode\nSensor S/N: 3594\nSensor Location Onboard: Main Lab / Wet Wall\nSensor Description: The Oxygen Optode is an optical sensor that does not consume oxygen. The measurement principle is based on fluorescence quenching, while traditional polorographic oxygen sensors, often called Clark sensors, based on electrochemical principles consume oxygen.\nParameter Description:\n\ncdm_data_type = Other\nVARIABLES:\ntime (seconds since 1970-01-01T00:00:00Z)\nspot_time (seconds since 1970-01-01T00:00:00Z)\nspot_value (Dissolved Oxygen Concentration Spot_Value, umol/l)\nmean (Dissolved Oxygen Concentration Mean, umol/l)\nstddev (Dissolved Oxygen Concentration Stddev, umol/l)\nminimum (Dissolved Oxygen Concentration Minimum, umol/l)\nmaximum (Dissolved Oxygen Concentration Maximum, umol/l)\nmedian (Dissolved Oxygen Concentration Median, umol/l)\nnum_values (Dissolved Oxygen Concentration Num_Values, unitless)\n https://coriolix.sikuliaq.alaska.edu/erddap/info/dissolvedoxygen_umolperl_oxygen003594_600sbin/index.htmlTable https://www.uaf.edu/cfos/sikuliaq/ (external link) https://coriolix.sikuliaq.alaska.edu/erddap/rss/dissolvedoxygen_umolperl_oxygen003594_600sbin.rss https://coriolix.sikuliaq.alaska.edu/erddap/subscriptions/add.html?datasetID=dissolvedoxygen_umolperl_oxygen003594_600sbin&showErrors=false&email= UAF dissolvedoxygen_umolperl_oxygen003594_600sbin

 
ERDDAP, Version 2.23
Disclaimers | Privacy Policy | Contact